• Title/Summary/Keyword: CAD-CAM (computer-aided design and computer-aided manufacturing)

Search Result 213, Processing Time 0.023 seconds

A Study on the Optimized Parting Surface Creation for a Micro Fan (마이크로 팬의 최적 금형파팅면 생성에 관한 연구)

  • 최상련
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.245-250
    • /
    • 1999
  • In order to design micro-fan appropriately, flow chacracteristics and mechanics should be carefully considered. The present work concerns with design procedure for a micro-fan using NACA(National Advisory Committee for Aeronautics) airfoil series. The generation of fan profiles is carried out automatically by defining related parameters, which is also converted to CAD/CAM data automatically. The optimal parting surface for the mold of micro-fan is also calculated by analyzing the geometric data numerically. As a consequence, the high capacity micro-fan can be developed successfully with a high-quality and an improved efficiency.

  • PDF

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

A case of digital maxillary complete denture and mandibular implant overdenture fabricated by CAD-CAM technique (완전 무치악 환자에서 CAD-CAM 기법을 이용한 상악 총의치 및 하악 임플란트 피개의치 수복: 증례 보고)

  • Kim, Kun Min;Oh, Kyung Chul;Kim, Sang Hyun;Han, Chol Gwan;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.442-450
    • /
    • 2021
  • The CAD-CAM technique is a rapidly developing field in the dental field and is applied to various fields of prosthetic treatment. Among them, the manufacturing of dentures using the milling technique classified as subtractive manufacturing is one of the commercialized digital full denture manufacturing methods. At the same time, it is possible to more efficiently manufacture a metal framework for implant overdenture by selective laser sintering or melting technique classified as an additive manufacturing method. The purpose of this article is to describe the fabrication of CAD-CAM maxillary complete denture and mandibular implant overdenture as well as its features.

Development of a DMU System Operated on a PDM System (PDM 시스템에서 운용되는 DMU 시스템 개발)

  • 이강수;이상헌
    • Korean Journal of Computational Design and Engineering
    • /
    • v.8 no.3
    • /
    • pp.157-166
    • /
    • 2003
  • In this paper, we explain the DMU (digital mockup) system based on the PDM system. Most manufacturing companies are trying to develop a competitive product by increasing the quality, shortening time to market (TIM) and reducing the cost of a product. Some technologies such as SE (System Engineering), CE (Concurrent Engineering), QFD (Quality Function Development), CI (Cost Innovation) and some systems such as CAD (Computer-Aided Design), CAE (Computer-Aided Engineering), CAM (Computer-Aided Manufacturing), PDM (Product Data Management) and visualization system are adopted for these purposes. Specially, DMU system utilizes a visualization system that shows the 3D shape of a product on the computer and it gives a quick intuition to a person whether he/she is an engineer or not. It also can induce the effects of CE and QFD. SO, 0 company is developing a DMU system integrating CAD, visualization and PDM system. The main feature of the developed DMU system is that it is entirely integrated with PDM system, which means that the 3D shape of any part or assembly can be retrieved through PDM system. The DMU system will change the development process, which will increase the competitiveness of a developed product.

Maxillary space closure using a digital manufactured Mesialslider in a single appointment workflow

  • Wilhelmy, Lynn;Willmann, Jan H.;Tarraf, Nour Eldin;Wilmes, Benedict;Drescher, Dieter
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.236-245
    • /
    • 2022
  • New digital technologies, many involving three-dimensional printing, bring benefits for clinical applications. This article reports on the clinical procedure and fabrication of a skeletally anchored mesialization appliance (Mesialslider) using computer-aided design/computer-aided manufacturing (CAD/CAM) for space closure of a congenitally missing lateral incisor in a 12-year-old female patient. The insertion of the mini-implants and appliance was performed in a single appointment. Bodily movement of the molars was achieved using the Mesialslider. Anchorage loss, such as deviation of the anterior midline or palatal tilting of the anterior teeth, was completely avoided. CAD/CAM facilitates safe and precise insertion of mini-implants. Further, mini-implants can improve patient comfort by reducing the number of office visits and eliminating the need for orthodontic bands and physical impressions.

Application of CAD-CAM technology to surgery-first orthognathic approach (디지털 기술을 이용한 선수술 악교정치료)

  • Kim, Yoon-Ji;Gil, Byung-Gyu;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.622-630
    • /
    • 2018
  • For successful surgery-first approach, accurate prediction of skeletal and dental changes following orthognathic surgery is essential. With recent development of digital technology using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, attempts to provide more predictable orthodontic/orthognathic treatment have been made through 3D virtual surgery and digital tooth setup. A clinical protocol for the surgery-first orthognathic approach using virtual surgery is proposed. A case of skeletal Class III patient with facial asymmetry treated by the surgery-first approach using digital setup and virtual surgery is presented. Advantages and limitations of applying CAD/CAM technology to orthognathic surgery are discussed.

  • PDF

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

Research on Engineering & Technology Education for Elementary School Student by using F1 in Schools Program (F1 in Schools 프로그램을 이용한 초등학생 대상 공학 기술 교육에 관한 연구)

  • Park, So-Ra;Nam, Hyun-Wook
    • Journal of Engineering Education Research
    • /
    • v.11 no.1
    • /
    • pp.85-100
    • /
    • 2008
  • The purpose of this study is development of 'F1 in Schools Program' for elementary school student and validation of the program. Fifteen students were originally chosen from the W elementary school in Cheongju, Chungcheogbuk-Do. The children were tested on their understanding of science and 'F1 in Schools Program'. After developing the 'F1 in Schools Program', it was used in the classroom to evaluate applicability and to examine the responses from students, parents and schools. The program consists of 60 classes and the time of each class is 40 minutes. This study was conducted for 10 days from January 22nd, 2007 to February 2nd, 2007. CAD(Computer Aided Design), CFD(Computation Fluid Dynamics), CAM(Computer Aided manufacturing) and CNC Machine were used in this study and proved to be good materials for students in that they increased the students' participation and imagination. However, the children's cognitive and creative abilities as well as manuals written in English hampered the process. Most students, parents, schools seemed to be satisfied with use of the program. However, the schools showed that there was not enough understanding of the program as a whole. The processes with which students build and inspect using the $CO_2$Model Car not only improves the processing of the model but also enhanced the students scientific understanding related to the car speed.

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

Treatment of upper and lower 3D printing CAD-CAM dentures using the POP (PNUD Occlusal Plane) Bow system, a prefabricated occlusal plane transfer device: A case report (조립식 교합 평면 인기 장치 POP (PNUD Occlusal Plane) Bow 시스템을 이용한 3D 프린팅 CAD-CAM 의치치료 증례)

  • Seol-Hwa Lee;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.44-54
    • /
    • 2023
  • In order to manufacture functional and esthetic prostheses, it is essential to accurately transmit information about the patient's occlusal plane. In particular, in the case of a completely edentulous patient, the occlusal plane is very important to correctly support the soft tissue, to achieve aesthetic harmony with the facial appearance, and to properly pronounce it, and to form a balanced occlusal relationship for stable mastication. In the conventional method, various facebow systems were used to transmit patient's information from the clinic to the laboratory, but there were several limitations in the process of transferring them to CAD. To simplify this process, a prefabricated POP (PNUD Occlusal Plane) Bow system was recently developed. In this case, a CAD-CAM (Computer-aided design-computer-aided manufacturing) treatment dentures reflecting the patient's occlusal plane information was manufactured using the POP Bow system during the treatment of a completely edentulous patient, and aesthetic and functional satisfaction was obtained.