• Title/Summary/Keyword: CAD-CAM

Search Result 1,371, Processing Time 0.026 seconds

Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method

  • Jeong, Yoo-Geum;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.245-251
    • /
    • 2018
  • PURPOSE. To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS. The RMS value ($152{\pm}52{\mu}m$) of the model manufactured by the milling method was significantly higher than the RMS value ($52{\pm}9{\mu}m$) of the model produced by the 3D printing method. CONCLUSION. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.

The implant overdenture on the edentulous mandible using CAD/CAM system: A case report (CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례)

  • Lee, Si-Eun;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.66-73
    • /
    • 2015
  • Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.

Discoloration of various CAD/CAM blocks after immersion in coffee

  • Lauvahutanon, Sasipin;Shiozawa, Maho;Takahashi, Hidekazu;Iwasaki, Naohiko;Oki, Meiko;Finger, Werner J.;Arksornnukit, Mansuang
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Objectives: This study evaluated color differences (${\Delta}Es$) and translucency parameter changes (${\Delta}TPs$) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE $L^{\ast}a^{\ast}b^{\ast}$ values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ${\Delta}Es$ and ${\Delta}TPs$ of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (${\alpha}=0.05$). The ${\Delta}Es$ after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results: After one month in coffee, ${\Delta}Es$ of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ${\Delta}TPs$ decreased. The ANOVA of ${\Delta}Es$ and ${\Delta}TPs$ revealed significant differences in two main factors, immersion periods and media, and their interaction except for ${\Delta}Es$ of TEL (Telio CAD, Ivoclar Vivadent). The ${\Delta}Es$ significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ${\Delta}Es$ and water sorption or solubility in water. Conclusions: The ${\Delta}Es$ of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs

  • Chaturvedi, Saurabh;Alqahtani, Turki;Alsolami, Saleh;Alqahtani, Abdulbari;Das, Gotam;Alsubaiy, Ebrahim
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.36-45
    • /
    • 2021
  • Purpose. To investigate the fracture resistance of monolithic CAD-CAM all-ceramic surveyed crowns with two different occlusal rest seat designs. Materials and Methods. Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconia-material (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. Results. The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P<.001). Conclusion. The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.

A Study on Development of Interactive CAM System for CNC Lathe (CNC 선반용 대화형 CAM 시스템 개발에 관한 연구)

  • Kim, Hui Jung;Jeong, Jae Hyeon;Park, Myeong Gyu;Kim, Jong Su;Choe, Hyeong Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.83-83
    • /
    • 1996
  • Recently, for enhanced productivity the induction of CAD/CAM is vigorous. Most of high-level CAD/CAM systems produce powerful faculties. But it is very expensive to purchase the system in small and difficult to be operated by non-experienced workers effectively. Then the resonable CAM system for these is needed. In this study we developed a proto-type of the CAM system for CNC lathe connecting with personal computer. This system is configured with interactive menu windows for easy control of CNC lathe. And the system supports tool path generation for cutting conditions of workpiece. The performance of this system is satisfactory.

A Study on Development of Interactive CAM System for CNC Lathe (CNC 선반용 대화형 CAM 시스템 개발에 관한 연구)

  • 김희중;정재현;박명규;김종수;최형식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.15-23
    • /
    • 1996
  • Recently, for enhanced productivity the induction of CAD/CAM is vigorous. Most of high-level CAD/CAM systems produce powerful faculties. But it is very expensive to purchase the system in small and difficult to be operated by non-experienced workers effectively. Then the resonable CAM system for these is needed. In this study we developed a proto-type of the CAM system for CNC lathe connecting with personal computer. This system is configured with interactive menu windows for easy control of CNC lathe. And the system supports tool path generation for cutting conditions of workpiece. The performance of this system is satisfactory.

  • PDF

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

A Study on Efficient Image Processing and CAD-Vision System Interface (효율적인 화상자료 처리와 시각 시스템과 CAD시스템의 인터페이스에 관한 연구)

  • Park, Jin-Woo;Kim, Ki-Dong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.18 no.2
    • /
    • pp.11-22
    • /
    • 1992
  • Up to now, most researches on production automation have concentrated on local automation, e. g. CAD, CAM, robotics, etc. However, to achieve total automation it is required to link each local modules such as CAD, CAM into a unified and integrated system. One such missing link is between CAD and computer vision system. This thesis is an attempt to link the gap between CAD and computer vision system. In this paper, we propose algorithms that carry out edge detection, thinning and pruning from the image data of manufactured parts, which are obtained from video camera and then transmitted to computer. We also propose a feature extraction and surface determination algorithm which extract informations from the image data. The informations are compatible to IGES CAD data. In addition, we suggest a methodology to reduce search efforts for CAD data bases. The methodology is based on graph submatching algorithm in GEFG(Generalized Edge Face Graph) representation for each part.

  • PDF

Design and Application of CAD/CAM Software Using the Script Functions (Scrpit 기능을 이용한 CAD/CAM Software의 설계 활용법)

  • Lee, Yang-Chang;Lee, Joon-Seong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.828-831
    • /
    • 2010
  • 본 논문은 CAD/CAM Software의 Script 기능을 이용하여 정밀한 자유곡선을 정확하고, 빠르게 생성할 수 있도록 하기 위한 기법을 연구 결과로서, 적용대상은 Equiangular Scroll Curve 생성을 대상으로 하였다. 관련 식을 검토하기 위하여 Excel Software을 이용하여 검증하였고, Visual Basic Language를 이용하여 보다 편리하게 Scroll Curve를 생성하는 기법을 연구하였다. 그 결과 여섯가지 변수를 설정하여 각각의 Scroll Curve를 생성하여 그 결과를 CAD 화면에 Drawing하여 도면을 생성, 편집할 수 있도록 하였다. 그리고 타 Software와 호환이 가능하도록 하여 다양한 Software에서 사용이 가능하도록 할 수 있게 하였다.

  • PDF

CAD/CAM System development for Stereolitihography (광조형용 CAD/CAM 시스템 개발)

  • 홍삼열;김준안;반갑수;백인환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.592-596
    • /
    • 1996
  • The CAD/CAM System oriented to StereoLithographic Rapid Prototyping was constructed and developed. The software architecture uses a 586PC running the windows NT operating system. An .STL file brought into the software program can be verified in divers view points and focused for a detail of concern. A variety of Entity was applied to define an array of triangular facets and sliced loops. The system provides Edit, Scale, Orient, Copy and Divide commands to modify .STL model. The NC codes are created according to various laser beam scan pattern and the software show the parts on the platform before they are constructed. This system is written in Visual C and has been proved as a powerful tool for producing solid parts directly from a CAD modelling, using actual applications.

  • PDF