• Title/Summary/Keyword: CAD-CAM

Search Result 1,371, Processing Time 0.027 seconds

A Study on the Mechanical Design and the 2.5-axial Combined Machining by CAD/CAM (CAD/CAM을 활용한 기계설계 및 2.5축 복합가공에 대한 연구)

  • Lee, Yang-Chang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.97-103
    • /
    • 2008
  • In this paper, the Post Process for the manifold complex processing using CAD/CAM Software of two and a half Dimensions(2.5D) has been developed to maximize the application of the manifold manufacturing machine. Many companies are currently making use of high price systems to improve manufacturing process using the multi-axial complex manufacturing machine. In accordance with the requirements, the utilization of CAD/CAM Software for the manifold complex manufacturing machine is earnestly demanded. However, the experts who have experience in manifold manufacturing machine are insufficient. Consequently the outcomes of the Post Process for 2.5D CAD/CAM Systems have been dealt in order to be smoothly operated by those who have basic skills and be understood in process drawings. CNC program functions can be specially used as they are, when drawn up. The Post Process for the original point designation and transformation of coordinates has been developed and applied. The results gave proof of practical manufacturing outcomes.

A study on the Flexural strength of zirconia CAD/CAM block (지르코니아 CAD/CAM block의 강도에 관한 연구)

  • Lee, Jung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.65-69
    • /
    • 2008
  • Recently, zirconia is widely used in the field of dental ceramics thanks to the proliferation of CAD/CAM systems. Accordingly, different types of zirconia block are being solid in the market. However, there are no precise, objective standards for properties of zirconia. This study concerns the flexural strength of zirconia ceramic for CAD/CAM block. The test specimens used for this study were ZirBlank(Acucera), ZirBlank shade(Acucera), VITA, Cercon(Densply) and Cerasys. The test results suggest that ZirBlank shade block shows the highest flexural strength and density among the zirconia blocks tested. Its flexural strength was $971{\pm}58MPa$ and its density was 99.89%. On the other hand, Cerasys block shows the lowest flexural strength of $576{\pm}36MPa$ and the lowest density of 94.85%. Given all, the density of the specimens is found to be directly proportional to strength and inversely to grain size.

  • PDF

A Dedicated CAM for Welding Automation System in Assembly Line at Shipyards (조선 대조립 용접라인의 CAD/CAM 시스템 적용)

  • Kim, Eun-Jung;Lee, Si-Youl;Kim, Byung-Su;Park, Jin-Hyung;Park, Young-Jun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1757-1762
    • /
    • 2003
  • For coping with various ship types easily, welding automation using CAD/CAM is demanded and and developed. In this paper we propose a dedicated CAM system which generates MACRO files to control robot manipulators. The paper contains CAD interface, virtual simulation, macro generation and job schedulling. At first, it defines and extracts weldline from CAD data, and generates proper MACRO programs. And it obtains optimum job schedules. This system removes the manual work, and consequently reduces the overall lead time. And it reduces costs and time for developing robot welding programs. This can be expanded to virtual factory simulation technology. Moreover, it is possible to apply this system for automation of Cutting and Painting

  • PDF

CAD/CAM System Development for Automatic Creation and Manufacturing of Three Dimension Objects (입체 형상의 자동생성 및 가공을 위한 CAD/CAM 시스템 개발)

  • 조성철
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.54-60
    • /
    • 1993
  • The purpose of this study is to develop a CAD/CAM system for automatic creation and manufacturing of three dimension objects. The computer system used in this study made RAM 2M, CPU 80386, VGA graphic card. The results in this paper are as follows ; 1. By interconnect PC(personal computer) and NC(numerical control) milling machine with RS232C connector, we was constructed with CAD/CAM system. 2. The developed algorithm in this study is able to be design of three dimension object on the computer CRT and manufacturing of NC milling machine. 3. Because of design and modifying on the PC of objects, we can be saving time, cost and improvable precision of objects. 4. Essentially, we expect industrial accident to reduse according as we takes advantage of CAD/CAM system.

  • PDF

Repair bond strength of resin composite to three aged CAD/CAM blocks using different repair systems

  • Gul, Pinar;Altinok-Uygun, Latife
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.131-139
    • /
    • 2020
  • PURPOSE. The purpose of this study is to evaluate the repair bond strength of a nanohybrid resin composite to three CAD/CAM blocks using different intraoral ceramic repair systems. MATERIALS AND METHODS. Three CAD/CAM blocks (Lava Ultimate, Cerasmart, and Vitablocks Mark II) were selected for the study. Thirty-two specimens were fabricated from each block. Specimens were randomly divided into eight groups for the following different intraoral repair systems: Group 1: control group (no treatment); Group 2: 34.5% phosphoric acid etching; Group 3: CoJet System; Group 4: Z-Prime Plus System; Group 5: GC Repair System; Group 6: Cimara System; Group 7: Porcelain Repair System; and Group 8: Clearfil Repair System. Then, nanohybrid resin composite (Tetric Evo Ceram) was packed onto treated blocks surfaces. The specimens were thermocycled before application of repair systems and after application of composite resin. After second thermal cycling, blocks were cut into bars (1 × 1 × 12 ㎣) for microtensile bond strength tests. Data were analyzed using two-way ANOVA and Tukey's HSD test (α=.05). RESULTS. Cimara System, Porcelain Repair, and Clearfil Repair systems significantly increased the bond strength of nanohybrid resin composite to all CAD/CAM blocks when compared with the other tested repair systems (P<.05). In terms of CAD/CAM blocks, the lowest values were observed in Vitablocks Mark II groups (P<.05). CONCLUSION. All repair systems used in the study exhibited clinically acceptable bond strength and can be recommended for clinical use.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

A Study on the Metal-Ceramic Bond Strength of CAD/CAM Metal Disk Alloy and Casting Alloy (CAD/CAM 전용 금속 합금과 주조용 합금의 세라믹 결합강도에 관한 연구)

  • Jung, Hyo-Kyung;Kwak, Dong-Ju
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.89-95
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate bond strength of Metal Disk alloy and casting alloy. Methods: Metal specimens were divided into 4 groups for each alloy. Three point flexural test were used to measure the bond strength of CAD/CAM metal alloy and casting alloy. Statistical analysis was done using the Statistical Package for Social Sciences version 19.0 for Windows. As for the analysis methods, the study used Kruskal-Wallis test. Results: The average bonding strengths of Group 1 to porcelain was $36.7{\pm}9.90$ MPa, Group 2 to porcelain was $37.68{\pm}4.51$ MPa, Group 3 to porcelain was $36.43{\pm}6.57$ MPa, Group 4 to porcelain was $42.88{\pm}6.81$ MPa, Each group was not significantly different. Conclusion: Bond strength of Casting alloy is equal to or higher than bond strength of CAD/CAM Metal Disk alloy. Alloy clinical bond strength is 25 MPa, So CAD/CAM Metal Disk alloy can be used as dental material.

CEREC 3D System을 이용한 당일수복 (one-day treatment) 임상증례

  • Jeong, Hyo-Gyeong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2008
  • Application of CAD/CAM is changing the way partial or full veneer all ceramic restoration is made. CAD/CAM systems, which were used mainly in other industries, have been developed and introduced for the dental purposes recently. It produced a flood of information on the CAD/CAM systems. It also influenced the development of restorative materials and all ceramic is substituting the traditional restorative materials of gold, composite resin and metal. Price increase of gold and other raw materials made the all ceramic more appealing. The introduction of a CEREC 3D system was innovative in several ways. Image of the prepared tooth is captured by camera and impression taking is unnecessary. Restoration can be delivered to the patient on one appointment and it will satisfy the demand of busy patients. One-day treatment with direct CAD/CAM system saves time compared to indirect CAD/CAM system. More superior restoration can be produced if lab work such as the adaptability check and shade selection is cooperated with lab technician. Short working time and comparably superior shade compatibility of color block was close to ideal. In the future, restorations with better quality can be fabricated in less time to busy patients thanks to the development of CAD/CAM system and dental materials.

  • PDF

Achieving Esthetics in Anterior Region using Monolithic Zirconia Restoration (Monolithic Zirconia Crown을 이용한 심미적 접근)

  • Kim, Chonghwa
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.4-14
    • /
    • 2016
  • Although CAD/CAM technology has been used in dentistry for more than decades, the present CAD/CAM dentistry is still quite inefficient or unesthetic. Zirconia restoration has faced with two contradictory words, 'Efficiency' and 'Esthetics'. One can consider monolithic zirconia restoration to be efficient with CAD/CAM. The monolithic zirconia restoration, however, is rarely esthetic due to the current limitations with zirconia. On the contrary, porcelain build-up is almost indispensible in fabricating esthetic restoration, especially in anterior region. In this article, the current status of monolithic zirconia restoration and clinical cases will be presented.

Study on The Strip Layout Design of LCD Shield Case Using 3D CAD/CAM (3차원 CAD/CAM을 활용한 액정용 실드 케이스의 스트립 레이아웃 설계에 관한 연구)

  • Choi, Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.979-983
    • /
    • 2007
  • In this thesis, a strip layout drawing of LCD S/C (shield case) was prepared. In the press die, strip layout drawing is a major factor that decides the mass production of a product. The 3D CAD/CAM system was applied for the easy correction of the interference factor with other parts to be mounted. The material use ratio was enhanced to 60.17% by optimizing the blank layout and strip layout in double width array. Furthermore, the flatness of the product was made to fit the requirements by adding the bidding process intensively on the notching part where the occurrence of the change in shape is expected owing to the thin material. For the 3D CAD/CAM software, Unigraphics NX3.0 was used. The strip layout drawing was prepared in 12 processes.

  • PDF