• 제목/요약/키워드: CAD/CAM materials

검색결과 293건 처리시간 0.027초

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

성공적인 캐드캠 수복을 위한 치아형성과 구강스캔 (Tooth preparation and Intraoral scanning for successful CAD/CAM restorations)

  • 배진우;손성애
    • 대한치과의사협회지
    • /
    • 제57권7호
    • /
    • pp.380-391
    • /
    • 2019
  • In recent years, with the introduction of various restorative materials, restorations using CAD/CAM equipment have been increasing in the esthetic dentistry. The critical steps in the fabrication of indirect restorations with CAD/CAM equipment are proper cavity preparation and making accurate impressions. The process of tooth preparation for CAD/CAM restoration should include a mechanical understanding of milling. In addition, during tooth preparation, the clinician should be familiar with additional equipment and techniques for obtaining the convenience. In order to obtain an accurate oral scan, the clinician should understand the limitations of the oral scan and be skilled at techniques for obtaining a successful image when making oral scans. This article focused clinical guidelines for the preparation of CAD/CAM restorations and introduced clinical methods for making successful impression of oral scans in narrow and deep tooth cavity areas.

  • PDF

임상가를 위한 특집 1 - CAD/CAM 보철물의 제작 과정에서 오류가 발생할 수 있는 요소들에 대한 경험적 고찰 (The factors caused errors in the production process of CAD/CAM prosthesis based on experience)

  • 허중보;심준성
    • 대한치과의사협회지
    • /
    • 제52권6호
    • /
    • pp.332-345
    • /
    • 2014
  • In recent years, precision machining of the dental prosthesis by computer assisted system is becoming pervasive in clinical dentistry. Prosthesis fabricating system that is designed by computer software and made by computer devices is called as a CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) system. By the use of dental CAD/CAM system, the improvement of marginal compatibility and mechanical properties in prosthesis can be obtained more effectively, an aesthetic quality by using new materials such as zirconia can be increased. Also, the restoration process can be simple and efficient, the production time can be shortened, the process of manufacture can be standardized, and the mass production is possible. What is clear is that these benefits are theoretically possible, but the dentist or dental technician must understand the CAD/CAM basic principles and limitations for obtaining the maximum advantages of CAD/CAM system. For this reason, this article will be presented about the basic principles of CAD/CAM system and the factors of error that might occur in the CAD/CAM process based on my empirical study.

Repair bond strength of resin composite to three aged CAD/CAM blocks using different repair systems

  • Gul, Pinar;Altinok-Uygun, Latife
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.131-139
    • /
    • 2020
  • PURPOSE. The purpose of this study is to evaluate the repair bond strength of a nanohybrid resin composite to three CAD/CAM blocks using different intraoral ceramic repair systems. MATERIALS AND METHODS. Three CAD/CAM blocks (Lava Ultimate, Cerasmart, and Vitablocks Mark II) were selected for the study. Thirty-two specimens were fabricated from each block. Specimens were randomly divided into eight groups for the following different intraoral repair systems: Group 1: control group (no treatment); Group 2: 34.5% phosphoric acid etching; Group 3: CoJet System; Group 4: Z-Prime Plus System; Group 5: GC Repair System; Group 6: Cimara System; Group 7: Porcelain Repair System; and Group 8: Clearfil Repair System. Then, nanohybrid resin composite (Tetric Evo Ceram) was packed onto treated blocks surfaces. The specimens were thermocycled before application of repair systems and after application of composite resin. After second thermal cycling, blocks were cut into bars (1 × 1 × 12 ㎣) for microtensile bond strength tests. Data were analyzed using two-way ANOVA and Tukey's HSD test (α=.05). RESULTS. Cimara System, Porcelain Repair, and Clearfil Repair systems significantly increased the bond strength of nanohybrid resin composite to all CAD/CAM blocks when compared with the other tested repair systems (P<.05). In terms of CAD/CAM blocks, the lowest values were observed in Vitablocks Mark II groups (P<.05). CONCLUSION. All repair systems used in the study exhibited clinically acceptable bond strength and can be recommended for clinical use.

3D face scan을 이용한 CAD/CAM 제작 의치 증례 (CAD/CAM fabricated complete denture using 3D face scan: A case report)

  • 엄대영;이성복;이석원;박수정;안수진
    • 대한치과보철학회지
    • /
    • 제55권4호
    • /
    • pp.436-443
    • /
    • 2017
  • 과거의 computer-aided design/computer-aided manufacturing (CAD/CAM) 기술 형태는 사용자가 한 제조사의 구성요소만 사용해야 하는 폐쇄적인 시스템이었다면, 현재는 여러 제조사의 구성요소 중 사용자가 필요에 맞는 구성요소를 선택해서 사용할 수 있는 유연성을 가진 개방적인 시스템 형태로 변화하였다. 치과재료와 보철물 제작 기술의 발전에도 불구하고 의치 제작은 지난 100년 가까이 전통적인 제작방식을 따랐다. 하지만 최근 들어 기존 의치 제작의 단점을 보완하고자 CAD/CAM 제작 의치에 관한 연구가 활발히 이루어지고 있으며, 밀링이나 3D 프린팅을 이용해 상용화된 형태의 CAD/CAM 제작 의치가 이미 임상에서 쓰이고 있다. 본 증례는 3D face scan을 활용한 CAD/CAM 의치 제작의 가능성을 확인하고, CAD/CAM과 전통적인 방법으로 제작한 의치를 비교한 결과에 대해 보고하고자 한다.

Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

  • Kwon, Taek-Ka;Pak, Hyun-Soon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.92-97
    • /
    • 2013
  • PURPOSE. All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS. The mean fracture strengths were as follows: $54.9{\pm}15.6$ N for the Lava CAD/CAM zirconia crowns and $87.0{\pm}16.0$ N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

디스크형 캠의 자동설계용 CAD S/W 개발-Part I :설계 및 해석 알고리즘 개발 (Development of CAD Software for Automatic Design of Disk-Typed Cams-Part I : Iterative Contact Method)

  • 손주리;신중호
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.149-154
    • /
    • 1989
  • Generally Cam-Follower systems consist of two elements: Cam is for rotating motion and follower for reciprocating motion. Depending on the shape of cam and type of follower, the motion of cam-follower system is determined. Thus design process and analysis process must be well defined. The design process means to find the coordinates of cam shape which can be defined the given motion of follower and the analysis process means to determine the motion curve of follower corresponding to the given cam based on the dimensions of a cam-follower system. This paper consists of two parts: One is development of a numerical method for design and analysis of cam-follower systems, the other is for development of a CAD program and its application. As the first part of the paper, an iterative contact method is proposed. This method can calculate the contact points between cam and roller and determine their contact angles iteratively. The second part of the paper presents the structure of a CAD program and its availability to the industrial applications.

  • PDF

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

치과 CAD-CAM용 임시 수복재의 색 안정성 비교 연구 (Comparative Study on the Color Stability of Temporary Prosthetic Materials for Dental CAD-CAM)

  • 이혜은;김원수;김정숙;이주희;원석재
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.165-173
    • /
    • 2016
  • Purpose: This study was conducted to examine the color stability of temporary prosthetic materials for dental CAD-CAM. Method: 2 kinds of existing acrylic resin temporary filling materials and 2 kinds of polymer prosthetic materials for dental CAD-CAM were used for testing, and five specimens respectively were absorbed in soy sauce, red pepper paste, and coffee. A Chroma Meter was used as analysis equipment. The color change of the specimens was observed to calculate ${\Delta}E$ value throughout 2 days, 3 days, 4 days, and 5 days and this was analyzed and the following result was obtained. Results: Snap's ${\Delta}E$ value was bigger than Vipi block(p<0.05). Red pepper paste had the largest impact on the color change of resin(${\Delta}E$), followed by soy sauce and coffee(p<0.000). With the passage of time, ${\Delta}E$ value was inversely(-) related and decreased somewhat(p<0.000).

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권2호
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.