• 제목/요약/키워드: CAD/CAM dental

검색결과 423건 처리시간 0.021초

The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

  • Sagsoz, Omer;Demirci, Tevfik;Demirci, Gamze;Sagsoz, Nurdan Polat;Yildiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.417-422
    • /
    • 2016
  • PURPOSE. The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS. Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples ($8{\times}8{\times}1mm$) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (${\alpha}=.05$). RESULTS. The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION. Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.

Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

  • Ekici, Mugem Asli;Egilmez, Ferhan;Cekic-Nagas, Isil;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.128-137
    • /
    • 2019
  • PURPOSE. The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS. 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and MannWhitney U tests (P<.05). RESULTS. Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION. Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.

의치상 첨상재의 종류와 임상적 고려사항 (Clinical considerations for complete denture relining)

  • 조영은
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.39-45
    • /
    • 2024
  • 의치상 하방의 잔존 치조제는 시간이 지남에 따라 생리적인 흡수가 일어난다. 이로 인하여 기존의 의치는 잔존 치조제와의 적합성이 떨어지게 되며, 임상적으로 교합평면의 변화, 수직고경의 감소, 의치의 유지력과 안정성의 소실로 인한 구강기능의 상실 및 심미적인 손상이 나타난다. 따라서 의치상과 잔존 치조제 사이의 첨상은 의치의 유지관리면에서 필수적이며 잔존 치조제와 의치상의 정확한 적합은 의치 치료의 성공을 결정하는 중요한 요인이 된다. 통상적인 첨상의 방법으로는 진료실에서 시행하는 직접법과 기공실에서 시행하는 간접법이 있다. 직접법은 진료실에서 시행하기 때문에 간편하고 쉽게 시행할 수 있는 장점이 있으나, 의치상 레진과 첨상재의 결합강도에 따라 영향을 받을 수 있는 단점이 존재한다. 반면, 간접법은 기공실에서 시행하며 첨상재와 의치상 레진간의 결합력을 제공한다는 장점이 있으나, 기공실 작업 기간 동안에 환자가 의치를 사용할 수 없다는 단점이 있다. 본 연구에서는 CAD-CAM의치를 포함하여 첨상에 사용하는 재료들과 각각의 특징들을 살펴보고, 첨상시 임상적으로 고려해야 하는 사항에 대해 알아보고자 한다.

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis

  • Peter Gehrke;Maria Julia Pietruska;Johannes Ladewig;Carsten Fischer;Robert Sader;Paul Weigl
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권4호
    • /
    • pp.231-243
    • /
    • 2024
  • PURPOSE. The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND METHODS. For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔEab) color scale values were recorded. RESULTS. The color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of allceramic crowns. There was a significant difference (P = .038) for the median ΔE value between blasted and non-blasted reconstructions at the cervical aspect of the crown. Full-ceramic crowns on zirconia Ti-base abutments exhibited significantly lower ΔE values below the threshold of visibility (ΔE 1.8). In all subcategories tested, the use of a highly opaque temporary cement demonstrated the lowest median ΔE for both the crown and the artificial gingiva. CONCLUSION. Various cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.

치과용 스캐너 전용 석고를 이용하여 제작된 3차원 디지털 모형의 정확도 평가 (An evaluation of validity of three dimensional digital model fabricated by dental scannable stone)

  • 김기백;김수진;김재홍;김지환
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.29-35
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(${\alpha}$=0.05). Results: No statistically significant differences between the two groups were found at intermolar distance, dental arch length(right)(p>0.05). However, intercanine distance, dental arch length(left) and two diagonal of dental arch lengths(right, left) were statistically significant(p<0.05). Conclusion: Stone models fabricated by dental scannable stone showed larger than digital models.

두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교 (Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations)

  • 신호식;김석규
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.528-534
    • /
    • 2008
  • 연구목적: 변연적합도는 보철수복물의 성공을 좌우하는 중요한 요소 중의 하나이다. McLean과 von Fraunhofer등에 의하면 120 ${\mu}m$ 이하를 임상적으로 허용할 수 있다고 했는데, 이를 넘는 정확하지 않은 변연은 지각과민을 일으키거나 이차 우식을 일으키고, 치태 축적을 용이하게 하여 보철물의 수명을 단축시키게 된다. 이에 최근에 우리나라에 소개되어 임상적으로 사용되고 있는 CAD-CAM 전부도재 수복물 중 $LAVA^{(R)}$ 시스템 (3M ESPE, St. Paul, MN)과 $EVEREST^{(R)}$ 시스템 (KaVo Dental GmbH, Biberach, Germany)으로 제작한 지르코니아 전부 도재관들이 도재전장 금속주조 수복물과 비교해 보아 코핑 상태일 때와 도재축성 후 각각 변연적합도의 차이가 있는지를 살펴보고자 하였다. 재료와 방법: 상악 제1소구치 덴티폼 치아를 high speed diamond bur 로 교합면 2.0 mm, 순설면 1.0 mm, 그리고 변연은 chamfer margin을 6도 측면 경사 절삭 기계로 균일하게 제작해서 이를 인상 채득하여 금속 지대치를 제작하였다. 이를 덴티폼 모형상에 장착한 후 전악인상을 채득하여 $LAVA^{(R)}$ 수복물 코핑, $EVEREST^{(R)}$ 수복물 코핑, 그리고 도재전장 금속주조 수복물 코핑을 각각 8개씩 제작하였다. 이들 코핑을 염색제를 섞은 Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan)를 이용하여 금속 지대치에 접합시킨 뒤, $Microhiscope^{(R)}$ system (HIROX KH-1000 ING Plus, Seoul, Korea)을 이용하여 300배율로 관찰하면서 변연 간격을 ${\mu}m$단위로 측정하였다. 도재축성 후에도 마찬가지 방법으로 모든 수복물의 변연간격을 측정하여 통계 처리를 하였다. 결과: 코핑 상태에서의 평균 변연간격 값은 $EVEREST^{(R)}$ 에서 $52.00{\pm}11.94\;{\mu}m$, $LAVA^{(R)}$$ 56.97{\pm}10.00\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $97.38{\pm}18.54\;{\mu}m$를 보였고, 도재축성 후에 평균 변연 간격값은 $EVEREST^{(R)}$$61.69{\pm}19.33\;{\mu}m$, $LAVA^{(R)}$$70.81{\pm}12.99\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $115.25{\pm}23.86\;{\mu}m$를 보였다. 결론: 1. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물은 도재 전장 금속 주조 수복물과 비교하여 각각 코핑상태일 때와 도재 축성 후 모두 유의성 있는 (P < .05) 차이를 보이는 우수한 변연 적합도를 나타내었다. 2. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물 간의 평균 변연 간격 비교에서 코핑 상태일 때와 도재 축성 후에 모두 유의성 있는 차이는 없었다 (P > .05). 3. $LAVA^{(R)}$$EVEREST^{(R)}$ 그리고 PFM 은 각각 코어 상태일 때와 비교하여 도재 축성 후 변연 간격에서 약간 증가되었으나 유의성 있는 차이를 보이지는 않았다 (P > .05).

상악 완전 무치악에서 $Locator^{(R)}$ attachment가 장착된 milled titanium bar를 이용한 임플란트 지지 피개의치: 증례 보고 (Implant Supported Overdenture using Milled Titanium Bar with $Locator^{(R)}$ Attachment on Fully Edentulous Maxillae : A Case Report)

  • 오상천;한지석;김민정
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.223-231
    • /
    • 2011
  • 본 증례 보고의 목적은 상악 무치악 환자에서 임플란트 지지 피개의치를 위한 $Locator^{(R)}$ attachment가 장착된 새로운 milled titanium bar를 소개하고 새로운 대안으로써의 가능성을 제시하고자 함이다. 56세 남자 환자가 상악 고정성 보철물(10-유닛 브릿지)의 동요도를 주소로 본원에 내원하였다. 악관절 및 치과 치료에 영향을 줄만한 특이한 전신병력은 없었다. 방사선 검사 및 임상 검사 결과, 상악의 경우 모든 잔존치아에서 심한 골흡수와 동요도를 보이고 있어 전악 발치를 시행한 후, 임플란트 지지 피개의치를 제작하기로 하였다. 의치의 안정성과 유지력, 저작효율, 청소의 용이성, 심미성과 발음 그리고 경제적인 측면을 고려하여 $Locator^{(R)}$ 어태치먼트를 CAD/CAM으로 제작된 milled titanium bar에 탭핑(tapping)으로 연결시키는 새로운 디자인을 고안하였으며, 1년 이상 경과 후, 기능과 심미적인 면에서 만족할 만한 성과를 얻었기에 이를 보고하는 바이다.

하악골 부분절제술 시행한 환자에서 CAD/CAM Zirconia Framework와 Monolithic Zirconia를 이용한 전악 수복 증례 (Full mouth rehabilitation in a patient with partial mandibulectomy using CAD/CAM zirconia framework and monolithic zirconia)

  • 마보영;박홍주;임영관;박찬;신진호;임현필
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.279-285
    • /
    • 2017
  • 구강암에 대한 외과적 처치로 구강 내 광범위한 경조직, 연조직을 제거한 환자는 저작, 연하, 발음 등의 기능적 문제와 치열, 안모의 심미적 문제를 갖게 된다. 악골 재건 후에도 치조골 등 합병증으로 인해 가철성 보철물의 유지 및 지지를 받는데 제한적이다. 임플란트 지지 고정성 보철물은 이러한 환자들에게 적절한 보철수복 방법이 되어 왔다. 본 증례는 하악 재건 후 computer-aided design과 computer-aided manufacturing을 이용하여 지르코니아 프레임워크 상부에 단일 구조 지르코니아 크라운을 제작하여 현재 치열의 기능적, 심미적 회복을 하여 이에 보고하고자 한다.

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

  • Sismanoglu, Soner;Gurcan, Aliye Tugce;Yildirim-Bilmez, Zuhal;Turunc-Oguzman, Rana;Gumustas, Burak
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권1호
    • /
    • pp.22-32
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment protocols. MATERIALS AND METHODS. Four different CAD/CAM blocks were used in this study: (1) flexible hybrid ceramic (FHC), (2) resin nanoceramic (RNC), (c) polymer infiltrated ceramic network (PICN) and (4) feldspar ceramic (FC). All groups were further divided into four subgroups according to surface treatment: control, hydrofluoric acid etching (HF), air-borne particle abrasion with aluminum oxide (AlO), and tribochemical silica coating (TSC). After surface treatments, silane was applied to half of the specimens. Then, a silane-containing universal adhesive was applied, and specimens were repaired with a composite, Next, µSBS test was performed. Additional specimens were examined with a contact profilometer and scanning electron microscopy. The data were analyzed with ANOVA and Tukey tests. RESULTS. The findings revealed that silane application yielded higher µSBS values (P<.05). All surface treatments were showed a significant increase in µSBS values compared to the control (P<.05). For FHC and RNC, the most influential treatments were AlO and TSC (P<.05). CONCLUSION. Surface treatment is mandatory when the silane is not preferred, but the best bond strength values were obtained with the combination of surface treatment and silane application. HF provides improved bond strength when the ceramic content of material increases, whereas AlO and TSC gives improved bond strength when the composite content of material increases.

3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례 (Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report)

  • 강세하;정승미;신재옥;방정환;김대환;최병호
    • 구강회복응용과학지
    • /
    • 제31권2호
    • /
    • pp.158-168
    • /
    • 2015
  • 본 증례는 상 하악 완전 무치악 환자에서 진단, 식립 그리고 보철물 제작에 디지털 방식을 활용하는 방법에 대해 제시하였다. 상악은 구개 부위, 하악은 기존 의치에 방사선 불투과성 마커를 부착한 후 구강스캔 및 CBCT 촬영을 시행하였다. 구강스캔 이미지와 CBCT 이미지를 중첩시켜 진단 및 수술가이드와 임시보철물을 제작하였다. 골유착 후에는 스캔바디를 이용한 구강스캔을 통해 최종보철물을 제작하였다. 임플란트를 이용한 전악수복에서 디지털 방식을 다양하게 활용하였으며 정확성과 환자의 불편감 최소화라는 목적에 만족할만한 결과를 얻었기에 이 증례를 보고하고자 한다.