• Title/Summary/Keyword: CAD/CAM dental

Search Result 417, Processing Time 0.022 seconds

Digital approach for fabrication of zirconia restoration with optimal gingival adaptation after tooth extraction: A case report (발치 후 지르코니아 보철물 제작에서 최적의 연조직 적합 형성을 위한 디지털 치료 증례)

  • Mai, Hang Nga;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.217-220
    • /
    • 2020
  • Conventionally, when a zirconia fixed dental restoration is planned, the interim restoration is made manually and the final restoration is fabricated by the silicone impression taking at the prosthodontic stage. This conventional workflow does not provide direct relation between interim and final restorations. Moreover, the predictability of the final restoration could be low. Nowadays, the CAD/CAM based restoration fabrication and related digital techniques are developed and being applied in dentistry in multiple ways. This case report introduces a digital workflow for fabricating an optimal gingival adaptation and predictability of monolithic zirconia restoration by using CAD/CAM interim restoration, intra oral scan, and image superimposition technique in a case that required tooth extraction.

Rehabilitation using mandibular implant overdenture with CAD/CAM milled bar: A case report (CAD/CAM 시스템으로 제작한 Milled Bar를 이용한 하악 임플란트 피개의치 수복증례)

  • Ban, Min-Hee;Yang, Hongso;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Shin, Jin-Ho;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.292-299
    • /
    • 2017
  • Long-term alveolar bone resorption in edentulous patient causes difficulty in denture use. Applying an implant overdenture with 2 to 4 implants to edentulous patient is easily approachable. Moreover, it improves denture stability, support, and retention. Milled bar, the attachment used in implant overdenture, can be used to induce better stability and retention to the supporting structure than conventional bar. It has become convenient to use due to the development of CAD/CAM system which had allowed the simplification of dental techniques. In this case, application of conventional maxillary full denture and mandibular overdenture made of CAD/CAM milled bar with 4 implants showed satisfactory results in the patient who had used upper and lower full dentures for a long time.

The fabrication of abutment crowns for existing removable partial denture using CAD/CAM: A clinical report (CAD/CAM을 이용하여 기존 국소의치에 맞는 지대치 보철물 제작 증례)

  • Chae, Min-Jeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.490-494
    • /
    • 2019
  • Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and the patient does not want to replace the existing removable partial denture, then a new prosthesis for abutment teeth need to be made. The procedure of fabricating a new prosthesis of abutment teeth for existing removable partial denture is complicate and technically challenging. To fabricate the abutment crown, the original cast of patient obtained before any complication to the abutment teeth is required. The original cast should also contain teeth other than the abutment teeth as a reference point. Once the cast is prepared, CAD/CAM could be used to produce retrofitting prosthesis effortlessly and efficiently. This clinical report presents fabricating a crown to fit existing removable partial denture using CAD/CAM for a patient with post and core failure and dislodged prosthesis. The prosthesis had high stability with minimum adjustment yielding satisfying result.

A case of digital maxillary complete denture and mandibular implant overdenture fabricated by CAD-CAM technique (완전 무치악 환자에서 CAD-CAM 기법을 이용한 상악 총의치 및 하악 임플란트 피개의치 수복: 증례 보고)

  • Kim, Kun Min;Oh, Kyung Chul;Kim, Sang Hyun;Han, Chol Gwan;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.442-450
    • /
    • 2021
  • The CAD-CAM technique is a rapidly developing field in the dental field and is applied to various fields of prosthetic treatment. Among them, the manufacturing of dentures using the milling technique classified as subtractive manufacturing is one of the commercialized digital full denture manufacturing methods. At the same time, it is possible to more efficiently manufacture a metal framework for implant overdenture by selective laser sintering or melting technique classified as an additive manufacturing method. The purpose of this article is to describe the fabrication of CAD-CAM maxillary complete denture and mandibular implant overdenture as well as its features.

원내에서 5축 밀링기로 가공한 PMMA temporary crown의 다양한 임상적 활용

  • Suh, Sangjin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.2
    • /
    • pp.68-83
    • /
    • 2017
  • With the increasing popularity of dental CAD / CAM, the kinds of materials that can be used and the range that can be utilized are also increasing. One of the biggest advantages of a dental CADCAM is that you can make a final prosthesis with one visit, but in case of zirconia or a complex aesthetic prosthesis, it is often difficult to make it in one day. In this case, temporary PMMA material can be used to provide a temporary crown with aesthetic and functional properties to the patient and can be used as a test crown or template for the final prosthesis. And if you are with a 5-axis milling machine in a clinic, you can make a temporary crown precisely to a large extent in a short time. In this article, various applications and clinical cases of PMMA temporary crown in the clinic will be presented.

Color stability of fully- and pre-crystalized chair-side CAD-CAM lithium disilicate restorations after required and additional sintering processes

  • Jurado, Carlos Alberto;El-Gendy, Tamer;Hyer, Jared;Tsujimoto, Akimasa
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.56-62
    • /
    • 2022
  • PURPOSE. The aim of this study was to investigate shade changes in fully- and pre-crystalized CAD-CAM lithium disilicate crowns after the required and additional firing processes. MATERIALS AND METHODS. One hundred and five crowns of shade A1 with high translucency were milled out of CAD-CAM lithium disilicate blocks and categorized as follows (n = 15): (1) restorations fabricated from Straumann n!ce with no additional sintering process; (2) restorations fabricated from Straumann n!ce with one additional sintering process; (3) restorations fabricated from Straumann n!ce with two additional sintering processes; (4) restorations fabricated from Amber Mill with one sintering process; (5) restorations fabricated from Amber Mill with two sintering processes; (6) restorations fabricated from IPS e.max CAD with one sintering process; (7) restorations fabricated from IPS e.max CAD with two sintering processes. All restorations were evaluated with a color imaging spectrophotometer. RESULTS. All restorations presented some color alteration from the original shade both after a single and after two firing processes. CONCLUSION. The required and additional sintering processes for restorations fabricated with chairside CAD-CAM lithium disilicate blocks cause an alteration of the original shade selected. Shade A1 high translucency restorations tend to change to a more yellowish B1 shade after a sintering process.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system (CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가)

  • Kim, So-Ri;Kim, Chong-Myeong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

Transformation of digital dentistry and the need of introducing education in dental hygiene (디지털 덴티스트리의 전환과 치위생교육 도입의 필요성)

  • Hye-Bin Go;Young-Joo Seo;Bok-Yeon Won;Sang-Hwan Oh
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.6
    • /
    • pp.467-475
    • /
    • 2022
  • Objectives: This study aimed to understand the definitions, types, and principles of computer-aided design/computer-aided manufacturing (CAD/CAM) and scanners due to the introduction of digital workflows. Methods: This study was based on information from the government's law and articles published in academic journals. Results: CAD/CAM is a technology that measures the shape three-dimensionally, saves it as data, designs it into the desired shape, and processes the product. Scanners, which are classified as intraoral and extraoral scanners, measure teeth and the intraoral environment three-dimensionally and convert them into three-dimensional (3D). A 3D printer is a machine that creates a 3D object by layering materials based on a 3D drawing. It can be classified into four types according to the method: extrusion, powder bonding, lamination, and photopolymerization methods. The most used 3D printer methods in dentistry are stereolithograhpy and digital light processing, and they are widely used in prosthetic, surgical, and orthodontic fields. Conclusions: As the dental system is digitized, it is expected that the government will classify the dental hygienist scope of work and the universities will reflect the curriculum; it is necessary to develop excellent dental hygienists, diversify the educational pathways, and establish policies to meet the needs of the increasing number of patients.

Esthetic Rehabilitation of Anterior Dentition by All Ceramic Crowns Using IPS e.max CAD : A Case of Tetracycline Discoloration (전치부 전부도재관을 이용한 테트라싸이클린 착색의 심미보철 회복 증례 (IPS e.max CAD 블록의 이용))

  • Kim, Jae-Hong;Cho, Young-kyu;Kim, Hae-Young
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.299-303
    • /
    • 2011
  • The purpose of this case report was to present an example of an esthetic and functional rehabilitation of anterior teeth with tetracycline discoloration and minor morphological abnormality of a 39-year old female. A chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with CEREC AC was applied for the prosthetic procedure and all ceramic crowns made with lithum disilicate (IPS e.max CAD) restored the esthetic and functional features of sixteen anterior teeth successfully.