• Title/Summary/Keyword: CAD/CAM 수복

Search Result 161, Processing Time 0.025 seconds

Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology (치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례)

  • Kim, Yuyeon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.330-338
    • /
    • 2022
  • For edentulous patients with unstable mandibular movements and abnormal facial features due to condylar fractures and morphological abnormalities, it is important to find a stable mandibular position. In this case, the patient's facial improvement, mandibular movement stability, and denture stability were improved by using flat table treatment dentures. In addition, computer-aided design/manufacturing (CAD-CAM) technology was used in denture fabrication to maintain the vertical dimension and lip support of flat table treatment dentures, we report good results in improving the patient's discomfort.

Maxillary anterior all ceramic restoration using digital impression and CAD/CAM (디지털 인상채득 및 CAD/CAM을 이용한 상악 전치부 보철물 제작과 기존 방식 보철물과의 임상적 비교)

  • Pyo, Se-Wook;Park, Young-Bum;Kim, Jee-Hwan;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.263-269
    • /
    • 2011
  • The digital impression technique has been developed for more precise restorations and convenient procedures in prosthodontic treatment compared to the conventional impression technique. Along with the utilization of CAD/CAM, the introduction of digital impression technique actualizes the digitalization of dental treatments. This case is to compare two different prostheses introducing each procedure in detail; one from CAD/CAM after taking digital impression and the other from the conventional technique. A 22-year-old female visited the clinic with the chief complaint of correction of discoloration and shape on maxillary right central incisor. Due to the trauma 8 years ago, the tooth was endodontically treated with post and resin core. The treatment was planned and the procedures were conducted under the patient's consent to treat the tooth with all ceramic crowns in two different ways for comparison. In conclusion, both prostheses presented clinically acceptable results with comparing the internal fitness of two all ceramic crowns. The prosthesis from digital impression, however, showed more errors in respect of internal fitness.

Clinical remarks about esthetics in the case of full zirconia restoration utilizing Zirkonzahn Prettau® block (지르코잔 프레타우 블럭을 이용한 Full Zirconia 수복 시 심미에 관한 임상적 소견)

  • Park, Jong-Chan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.30-46
    • /
    • 2013
  • Porcelain fused to metal crown has been used mostly over the last 50 years for restorations in dentistry. However, the patients' awareness of aesthetic aspect, biocompatibility and the problems such as an allergy to metals led to the growing interest in the 'metal free restoration'. In particular, the price of the precious metals that have been mainly used to date has risen drastically, which made them impossible to play their role as oral restorative materials anymore, and in addition, the PFM restoration has intrinsic problems of chipping and fracture. Therefore, the CAD/CAM has been drawing more attention than ever due to the popular needs for the material that is more aesthetic and stronger for restoration of the molar implant. Considerations in carrying out the full zirconia restoration are as follows: 1) strength, 2) combination work, 3) light penetrability, 4) treatment of cracks, 5) the color reproducibility of the block, 6) the abrasivity of antagonistic tooth, 7) low temperature degradation. In this presentation, the color reproducibility of the block will be discussed. One of the biggest reasons for avoiding the full zirconia restoration is that it is difficult to reproduce the natural color compared to the conventional PFM restoration. Thus, many clinicians show reluctance due to the exposure of the ugly block when the coloring on the surface is removed after occlusal adjustment. From the experience of using blocks by Zirkonzahn for more than 4 years, it is considered that these problems can be addressed to some degrees. Accordingly, how to make restorations that are well in harmony with surrounding prosthesis or natural teeth will be discussed.

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

RADIOPACITY OF CAD/CAM CERAMICS (CAD/CAM용 도재의 방사선 불투과성에 관한 연구)

  • Lee, Jong-Hyeok;Choi, Han-Seuk;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.357-365
    • /
    • 1998
  • 목적: 치과용 수복재료의 방사선 불투과성은 매우 다양하다. 따라서 다양한 수복재료의 방사선 불투과성을 인지하여 치질과 비교하면 이차우식의 진단에 도움이 될 수 있다. 도재의 방사선 불투과성에 따라 적절한 luting cement의 선택이 가농해진다. 수복재료의 방사선 불투과성은 알루미늄 step wedge 의 후경과 방사선 불투과성과의 상관관계 의해 측정된다. 본 연구의 목적은 CAD/CAM용 도재와 이틀의 접착에 쓰이는 접착재료의 방사선 불투과성을 조사해 적절한 재료의 선택과 이차우식 진단의 효율결정에 도움이 되게 하는데 있다. 방법: 본 실험에서는 CAD/CAM용 도재인 Vita MarkII, Dicor MGC와 이의 접착에 사용되는 Z-100, 그리고 luting cement인 Duo cement, Scotchbond resin cement를 사용해 방사선 불투과성을 측정하였다. 시편 제작을 위해 도재를 저속절단기로 두께 2mm, 3mm로 절단하였으며 Z-100과 cement시편은 두께 2mm와 3mm, 직경 7.0mm의 금속 주형을 제작한 후 재료를 양쪽 면에 유리판을 대고 조임쇠로 압접하였으며 광조사기를 사용하여 각 재료마다 두 가지 두께로 10개씩 100개의 시편을 제작하였다. 치질의 시편을 얻기 위해 교정 목적으로 최근에 발거된 정상적인 상악 소구치를 저속 절단기를 사용하여 협설측 교두정을 기준 삼아 2mm, 3mm 두께로 절단하였으며 방사선 불투과성의 기준을 위해 12개의 step으로 구성된 12mm두께의 aluminum step wedge를 사용하였다. Kodak E-Speed occlusal film에 aluminum step wedge와 시편들을 위치시킨 후 70kVp, 7mA, 2.16mm aluminum filtration으로 고정된 dental X-ray unit을 사용하여 target과 film 사이의 거리는 25cm, 노출시간은 0.2초로 하여 방사선 촬영을 한 다음, 현상된 방사선 사진상에 나타난 방사선 불투과성을 X-rite 301 densitometer를 이용하여 측정한 값들의 평균을 냈다. 얻어진 결과는 one-way ANOVA Duncan test(P<0.01)로 검증하였다. 결론: 1. Dicor MGC의 방사선 불투과성은 법랑질보다 약간 높게 나타났다.(P<0.01) 2. Vita Mark Il는 상아질보다 낮은 방사선 불투과성을 보였다.(P<0.01) 3. Z-100과 Luting cement들의 방사선 불투과성은 법랑질보다 높았다. Duo cement가 방사선 불투과성이 가장 높았고 그 다음이 Z-100, 그리고 Scotchbond resin cement 순이었다. 4. Z-100과 2종류의 방사선 불투과성 luting cement들은 Vita Mark II 와 같이 사용하면 2차우식 진단에 도움이 된다.

  • PDF

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

Full mouth rehabilitation using zirconia crown in severe worn dentition: a case report (마모가 심한 환자에서 지르코니아 크라운을 이용하여 전악 수복한 증례)

  • Park, Jung-Hyun;Sohn, Sang-Hyuk;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.202-208
    • /
    • 2016
  • The progressive attrition of teeth is a normal process by aging. However, excessive tooth wear with decreased vertical dimension of occlusion and collapse of occlusal plane may cause pathologic pulpal condition, occlusal disharmony and functional disorders. In this case, a patient with severely worn dentition was treated. Diagnostic wax-up was performed at the increased vertical dimension. After evaluation of provisional restorations for 12 weeks, final restorations were fabricated with zirconia crown and routine clinical assessments were made. Esthetically and functionally satisfactory results were obtained.

Digital impression taking for full-arch implant restoration to a patient with microstomia (디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복)

  • Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF