• Title/Summary/Keyword: C2 end plate

Search Result 45, Processing Time 0.021 seconds

Bearing Capacity Study for Small-Scale Testing of Rotary Pile with Helix Plate (축소모형 로타리 파일의 나선날개에 따른 지지성능에 관한 연구)

  • Shin, Eun-Chul;Kim, Kyeong-Sig;Moon, Hyeong-Rok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.37-46
    • /
    • 2016
  • Rotary pile consists a single or multiple helix plate and it is installed into the ground using the rotation of the helix plate. Rotary pile in soft ground is able to be supported by pile shaft and helix plate. When the pile is installed into hard layer relatively, the end bearing capacity is possible to be increased by the lower helix plate. In this paper, small-size rotary piles were manufactured with using steel pipe which is reduced to 1/5 size of the rotary pile on the construction field. Pile load test was carried out on the foundation soil which was formed by weathered soft soil. The bearing capacity of small-scale piles depends on the number of helix plate, the length of plate diameter, and an interval of plates, respectively. The bearing capacity of pile increases about 40% with 3 helix plate and it is also confirmed that the bearing capacity is improved about 10% as the increment of plate interval.

Active shape change of an SMA hybrid composite plate

  • Daghia, Federica;Inman, Daniel J.;Ubertini, Francesco;Viola, Erasmo
    • Smart Structures and Systems
    • /
    • v.6 no.2
    • /
    • pp.91-100
    • /
    • 2010
  • An experimental study was carried out to investigate the shape control of plates via embedded shape memory alloy (SMA) wires. An extensive body of literature proposes the use of SMA wires to actively modify the shape or stiffness of a structure; in most cases, however, the study focuses on modeling and little experimental data is available. In this work, a simple proof of concept specimen was built by attaching four prestrained SMA wires to one side of a carbon fiber laminate plate strip. The specimen was clamped at one end and tested in an environmental chamber, measuring the tip displacement and the SMA temperature. At heating, actuation of the SMA wires bends the plate; at cooling deformation is partially recovered. The specimen was actuated a few times between two fixed temperatures $T_c$ and $T_h$, whereas in the last actuation a temperature $T_f$ > $T_h$ was reached. Contrary to most model predictions, in the first actuation the transformation temperatures are significantly higher than in the following cycles, which are stable. Moreover, if the temperature $T_h$ is exceeded, two separate actuations occur during heating: the first follows the path of the stable cycles; the second, starting at $T_h$, is similar to the first cycle. An interpretation of the phenomenon is given using some differential scanning calorimeter (DSC) measurements. The observed behavior emphasizes the need to build a more comprehensive constitutive model able to include these effects.

Effect of Inlet Geometries on the Two-Phase Flow Distribution at Header-Channel Junction (헤더-채널 분기관에서의 헤더 입구 형상이 2상 유동 분배에 미치는 영향에 대한 실험적 연구)

  • Lee, Jun Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.324-330
    • /
    • 2013
  • The main objective of this work is to experimentally investigate the effect of inlet geometries on the distribution of two-phase annular flow at header-channel junctions simulating the corresponding parts of compact heat exchangers. The cross-section of the header and the channels were fixed to $16mm{\times}16mm$ and $12mm{\times}1.8mm$, respectively. Experiments were performed for the mass flux and the mass quality ranges of $30{\sim}140kg/m^2s$ and 0.3~0.7, respectively. Air and water were used as the test fluids. Three different inlet geometries of the header were tested:no restriction (case A), a single 8 mm hole at the center (case B), and nine 2 mm holes around the center (case C) at the inlet, respectively. The tendencies of the two-phase flow distribution were different, in each case. For cases B and C (flow resistance exists), more uniform flow distribution results were seen, compared with case A(no flow resistance), due to the flow pattern change to mist flow from annular flow at the inlet, and the flow recirculation near the end plate of the header.

Toxic Algal Bloom Caused by Dinoflagellate Alexandrium tamarense in Chindong Bay, Korea

  • Yoo Jong Su;Fukuyo Yasuwo;Cheun Byeungsoo;Lee Sam Geun;Kim Hak Gyoon
    • Fisheries and Aquatic Sciences
    • /
    • v.3 no.1
    • /
    • pp.26-32
    • /
    • 2000
  • Monospecific red tide by a toxic dinoflagellate belonging to the genus Alexandrium occurred at Chindong Bay in the southern coast of Korea and continued from April 6th to 15th in 1997. The ratio of its cell number to total phytoplankton cell number was much higher than $95\%$. This organism was identified as Alexandrium tamarense, although slight morphological differences were found comparing to the original and successive descriptions of the species. We found neither anterior nor posterior attachment pores in these cells of the bloom population. The occurrence of red tide caused by A. tamarense was first reported in Korea. Its plate formula is Po, Pc, 4', 6"c, 8s, 5"' and 2"". Thecal plates are thin with pore-like ornamentation. In those plates, the anterior part of the first apical plate (1') is narrower and its posterior end has sometimes a block-like accessory, but this variation was considered within the range of the morphological variability of this taxon. The cell density during the red tide exhibited a wide range of variation by the depth of water column, ranging from $2\times10^6$ cells$l^{-1}$ to $5\times10^6$ cells·$l^{-1}$. Water temperature varied from 11.8 to $12.3^{\circ}C$. Toxicity of A. tamarense during red tide was measured as $8.8\times10^5$. $MU\;\cdot\;cell^{-1}$ by mouse bioassay.

  • PDF

Selective Response of the Sea Bass and the Gray Rock Cod to the Colored Twines (농어 및 볼낙의 색망사에 대한 선택반응)

  • 염말구
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 1981
  • The selective response of the sea bass, Lateolabrax japonieus and the gray rock cod, Sebastes inermis to the colored twines was studied in a white tiled aquarium C400LX60WX70H em), by use of Y -maze made of gray plastic plate. Anyone of the different colored twines, white, black, blue, yellow and red, was strung crosswise on a rectangular frame which was mounted to one of the two outlet ends of Y -maze, and another colored twine was used to the other end of the Y -maze. In each trial, a fish was guided toward the inlet of the Y -maze to let the fish select either one of the two different colored twines. The results obtained are aS follows: 1. Sea bass preferably selected the colored twines in a order of white, blue, yellow, black and red with significant difference. 2. Gray rock cod showed little difference in selecting colored twines even though the fish selected white one a little more frequently.

  • PDF

Antibacterial evaluation of recombinant lysozyme-HJP24 proteins against various bacterial pathogens, and of its possibility test as a feed additive in piglets (재조합 lysozyme-HJP34 단백질의 다양한 병원성 세균에 대한 항균 효능 및 자돈 사료첨가제의 가능성 평가)

  • Yu, Jeong-Hee;Yu, Yeong-Ju;Kim, Seon-Min;Hur, Jin
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.4
    • /
    • pp.247-256
    • /
    • 2021
  • The recombinant lysozyme-HJL34 proteins were expressed and purified using commercial Escherichia (E.) coli expression system. Stx2e+ F18+ E. coli, Actinobacillus pleuropneumoniae (APP), Streptococcus (S.) suis, and Clostridium (C.) perfringens strains were isolated from pigs. The minimum inhibitory concentrations (MICs) of the recombinant lysozyme-HJP34 proteins were examined by means of the microtiter plate method, according to the NCCLS recommendations. The possibility of its as the alternatives to antibiotics was tested in piglets. The MICs were determined as 75 ㎍/mL, 300 ㎍/mL, 75 ㎍/mL, 35.5 ㎍/m against Stx2e+ F18+ E. coli, APP, S. suis, C. perfringens, respectively. A total of 25 piglets were divied 5 groups. The piglets in group A~C were fed with commercial feed and those in groups D, E were fed with commercial feedstuff. All piglets in groups B~E were challenged with virulent Stx2e+ F18+ E. coli, APP, S. suis strains. Groups C and D were treated with antimicrobial from 24 h after challenge. All piglets in group B died within 3 days after challenge. Among 5 piglets in groups C and D piglets, 80% survived after challenge. Among group E piglets, 60% were alive until the end of this study. Therefore, this study indicates that recombinant lysozyme-HJP34 proteins is a suitable possibility as a feed additive for reduction of diseases by bacterial pathogens in piglet feed.

Biomechanical Effect of In-line Skating Wrist Guards on the Prevention of Wrist Fracture

  • Lim, Tae-Hong;Linda M. McGrady;Peter Hoepfner;Craig C. Young;William G. Raasch;Han, Jung-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1072-1076
    • /
    • 2001
  • A biomechanical study was conducted in this study to investigate if in-line skating wrist guards can effectively reduce the impact forces so as to protect the wrist from fracture. The forearm specimens with and without wrist guards were dropped using a specially designed sled to simulate the impact on the wrist while falling. A force plate was used to measure the total impact force on the dropping weight whereas a load cell was attached to the proximal end of the specimen and used to quantify the impact transmitted through the wrist joint. From the non-destructive tests, mean peak force measured from a force plate showed no difference between the guarded and unguarded groups whereas mean impulse of the guarded group was significantly greater than that of the unguarded group (p<0.01). Comparing the peak force and impulse measured from the load cell, the peak force of the guarded group was significantly less than that of the unguarded group (p<0.001), while the impulse values were similar. When the specimens were dropped from a higher position (2.5ft ve. 1ft), all unguarded specimens had severe wrist fractures whereas fracture was found in three out of 5 guarded specimens. Comparison of mean peak forces and impulses showed as significant difference between the guarded and unguarded groups only in the mean impulse measured from the force plate. These results suggest that the wrist guard may protect the wrist by attenuating the peak force transmitted to radius and ulnar although it may not be effective when the wrist is subjected to an impact sufficiently large to cause fractures.

  • PDF

Quality Changes of Aseptic Packaged Cooked Rice during Storage (무균포장밥의 저장중 품질 변화에 관한 연구)

  • Kum, Jun-Seok;Lee, Chang-Ho;Lee, Sang-Hyo;Lee, Hyun-Yu
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.449-457
    • /
    • 1995
  • Aseptic packaged cooked rice without oxygen absorber and EVOH material was not suitable for good quality during long storage at room temperature. Quality change of aseptic packaged cooked rice with OPP/EVOH/EPL(P-1), PET/EVOH/EPL(P-2) and OPP/EVOH/LLDPE(P-3) for lid material and FX and TSQ for oxygen absorber was observed during storage(60 days) at $20^{\circ}C,\;30^{\circ}C\;and\;40^{\circ}C$. To evaluate quality change of aseptic packaged cooked rice, water content, color, pH, acidity, hardness, and total plate count were measured periodically. The results showed that moisture content was decreased as storage time increased while storage temperature showed no significant effect. P-2 and FX combination had the lowest evaporation of water. L value was decreased as storage time increased while a value increased in all treatment. P-2 and FX combination had the best result for color value. Titratable acidity and pH of P-3 increased up to 20, 5.5, respectively at the end of storage while the other treatment showed no significant effect. Hardness of aseptic packaging of cooked rice was decreased as temperature of storage increased while lid materials and oxygen absorber types showed no significant effect. Result of total plate count showed that there was no detection for $20^{\circ}C\;and\;30^{\circ}C$ storage temp. while more than $1{\times}10^6\;CFU/g\;for\;40^{\circ}C$ storage temp. at the end of storage. In conclusion, aseptic packaged cooked rice could be stored and distributed for 6 month at room temp. and effect of lid materials on quality change of aseptic packaged cooked rice was more significant than oxygen absorber.

  • PDF

Cyclic performance and design recommendations of a novel weak-axis reduced beam section connection

  • Lu, Linfeng;Xu, Yinglu;Liu, Jie;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.27 no.3
    • /
    • pp.337-353
    • /
    • 2018
  • In previous weak-axis moment connection tests, brittle fracture always initiated near the edge of the beam flange groove weld due to force flow towards the stiffer column flanges, which is the opposite pattern as strong-axis moment connections. As part of the China NSFC (51278061) study, this paper tested two full-scale novel weak-axis reduced beam section moment connections, including one exterior frame connection specimen SJ-1 under beam end monotonic loading and one interior frame joint specimen SJ-2 under column top cyclic loading. Test results showed that these two specimens were able to satisfy the demands of FEMA-267 (1995) or ANSI/AISC 341-10 (2010) without experiencing brittle fracture. A parametric analysis using the finite element software ABAQUS was carried out to better understand the cyclic performance of the novel weak-axis reduced beam section moment connections, and the influence of the distance between skin plate and reduced beam section, a, the length of the reduced beam section, b, and the cutting depth of the reduced beam section, c, on the cyclic performance was analyzed. It was found that increasing three parametric values reasonably is beneficial to forming beam plastic hinges, and increasing the parameter a is conducive to reducing stress concentration of beam flange groove welds while increasing the parameters b and c can only reduce the peak stress of beam flange groove welds. The rules recommended by FEMA350 (2000) are suitable for designing the proposed weak-axis RBS moment connection, and a proven calculation formulation is given to determine the thickness of skin plate, the key components in the proposed weak-axis connections. Based on the experimental and numerical results, a design procedure for the proposed weak-axis RBS moment connections was developed.

Development of ELISA for detection of canine brucellosis (Canine brucellosis 검출을 위한 ELISA 진단법 확립)

  • Hur, Jin;Baek, Byeong-Kirl
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.2
    • /
    • pp.159-166
    • /
    • 2011
  • This study was carried out to develope enzyme-linked immunosorbent assay (ELISA) for detection of canine brucellosis in dogs experimentally inoculated with Brucella abortus 1119-3 and B. canis RM666. Groups A, B and C of dogs (each group consisting of three dogs) were orally inoculated with approximately $5{\times}10^9$ colony-forming units of B. abortus and B. canis, and with sterile pyrogen-free PBS, respectively. The animals were monitored at regular intervals upto the 12th week post inoculation (PI) by standard tube agglutination test (STAT), plate agglutination test (PAT), Rose Bengal test (RBT), 2-mercaptoethanol rapid slide agglutination test (2ME-RSAT) and ELISA. The induced antibody titers in group A dogs were detected from the first week PI to the eighth week PI in STAT, PAT and RBT using the inactivated whole cells of B. abortus 1119-3 as antigens, while no sera in groups B and C dogs reacted with the antigens. In 2ME-RSAT using whole cells of B. canis M-strain as antigens, the induced antibody titers in group B dogs were observed at the second week PI and persisted for the 12th week PI, while sera of groups A and C dogs did not react with the whole cells. In ELISA using cytoplasmic fractions antigen of B. abortus 1119-3, the mean optical density of antibodies in groups A and B was detected from the first and second weeks PI, respectively, and persisted for 12th week PI, while sera of group C did not cross-react with the fractions antigen. However, in ELISA using the hot saline extracts of B. canis M- as an antigen, the induced antibody titers in only group B dogs were detected from second week PI and persisted for until the end of this study. These results indicate that the ELISA using B. abortus 1119-3 cytoplasmic fractions as antigens can be a good candidate for detection of brucellosis by B. abortus as well as B. canis in dogs.