• Title/Summary/Keyword: C2 architecture

Search Result 1,119, Processing Time 0.024 seconds

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

Optimization of T/C Lifting Plan using Dependency Structure Matrix (DSM) (DSM을 활용한 타워크레인 양중계획 최적화에 관한 연구)

  • Kim, Seungho;Kim, Sangyong;Jean, Jihoon;An, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.151-159
    • /
    • 2016
  • Tower crane (T/C) is one of the major equipment that is highly demanded in construction projects. Especially, most high-rise building projects require T/C to perform lifting and hoisting activities of materials. Therefore, lifting plan of T/C needs to reduce construction duration and cost. However, most lifting plan of the T/C in construction sites has still performed depending on experience and intuition of the site manager without systematic process of rational work. Dependency structure matrix (DSM) is useful tool in planning the activity sequences and managing information exchanges unlike other existing tools. To improve lifting plan of T/C efficiently, this study presents a framework for the scheduling T/C using DSM through the case study in real world construction site. The results of case study showed that the scheduling T/C using DSM is useful to optimize the T/C lifting plan in terms of easiness, specially in the typical floor cycle lifting planning.

The Study of Ibuprofen Degradation Properties by Combination of Wave Energy (Ultrasound, Ultraviolet) and Persulfate Ion (파 에너지 (자외선, 초음파)/과황산나트륨을 이용한 이부프로펜 분해특성 연구)

  • Na, Seungmin;Ahn, Yungyong;Cui, Mingcan;Son, Younggu;Khim, Jeehyeong
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.963-972
    • /
    • 2014
  • In this study, ibuprofen(IBP) degradation by the photochemical ($UV/S_2O{_8}^{2-}$) and sonochemical ($US/S_2O{_8}^{2-}$) processes was examined under various parameters, such as UV ($10{\sim}40{\pm}5W/L$) and US ($50{\sim}90{\pm}5W/L$) power density, optimum dosage of persulfate ion ($S_2O{_8}^{2-}$), temperature ($20{\sim}60^{\circ}C$) and anions effect ($Cl^-$, $HCO_3{^-}$, $CO{_3}^{2-}$). The pseudo-first-order degradation rate constants were in the order of $10^{-1}$ to $10^{-5}min^{-1}$ depending on each processes. The synergistic effect of IBP degradation in $UV/S_2O{_8}^{2-}$ and $US/S_2O{_8}^{2-}$ processes could investigated, due to the generation of $SO_4{^-}$ radical. This result can confirm from the produced $H_2O_2$ and $SO{_4}^{2-}$ concentration in each processes. IBP degradation rate affected by the $S_2O{_8}^{2-}$ dosage, temperature, power and anion existence parameters. In particular, IBP degradation rate increased with the increase of the temperature ($60^{\circ}C$) and applied power density (UV:$40{\pm}5W/L$, US:$90{\pm}5W/L$). On the other hand, anions effect on the IBP degradation was negative, due to the anion play as a the scavenger of radical.

A Study on National Defense Enterprise Architecture Framework (국방 전군적 아키텍처 프레임워크에 관한 연구)

  • 이태공;김진우
    • Journal of the military operations research society of Korea
    • /
    • v.29 no.2
    • /
    • pp.45-60
    • /
    • 2003
  • As we live in real If era, If become a mandatory component for nations and organizations to survive in severe competition. If is also thought of as strategic asset for effective business operations, yet there is no proved statement on the interoperability and system integration which causes serious problem in terms of requirement engineering among current systems. The National Defense Enterprise Architecture Framework is a strategic information asset base, which define the military operation activities for the mission, the information necessary for military operations, the technologies necessary for implementing new technology in response to changing operational needs. It is an integrated model or representation. Information Systems will be evolved by the National Defense Enterprise Architecture framework. The purpose of this framework is to present overall picture of national defense information system domain so that information systems are interoperated, integrated and information sharing is increased among affiliated organization of Defense Military.

An Interpretation of Contextualism as Architectural Theory(1) (맥락주의를 건축이론화 하기 위한 시도(1))

  • Lee, Dong-Eon
    • Journal of architectural history
    • /
    • v.8 no.2 s.19
    • /
    • pp.109-118
    • /
    • 1999
  • The purpose of this paper is to apply Stephen C. Pepper's contextualism to architecture: to interpret the former in the light of architectural theory, and ultimately to liberate architecture from the Western 'Idea' and return it to its context. The major concepts of Pepper used in the paper are quality, texture, spread, change, fusion, strand and context. Pepper's contextualism makes us realize that architecture cannot be separated from its context where human beings, history, neighborhood, and nature are all interpenetrating, and create a quality. Contextualism thus teaches us to make an effort to understand the region where we belong, and to create an architectural device that interrelates form and function of an architecture with its space-time environment, or its strand, texture and context.

  • PDF

Poetic Dwelling and, Word-Semiotic Substitution of Being-in-the World - Critical Interpretation of Modern Architecture through C.N.Schulz's 'Genius Loci' - (시적 거주와 세계내 존재의 언어기호적 치환 - 슐츠의 '장소성' 이론을 통한 현대건축의 비평적 이해 -)

  • Byun, Tae-Ho
    • Journal of architectural history
    • /
    • v.6 no.2 s.12
    • /
    • pp.53-64
    • /
    • 1997
  • The language of architecture is a kind of tool which helps people to experience the environment not as the thing itself but as a meaningful one. It, gathered by place, constitutes 'genius loci', as the existential structures. It, in other words, gives a thing 'cognitive quality', and serve people to 'dwell' because 'a place is a gathering thing with concrete presence.' Our environment, only when it possesses the language, presents itself as a namable thing or an understood world. Such a meaningful identification is dwelling. The modern world is a complex melting-pot. It is 'complexities' and 'contradiction'. The language of architecture is never created, rather it is selected by needs of the time and the place. In this sense, architectural design means discovery and interpretation of the poetic order of architypal form and style, and the poetic order is a way for people to dwell in the humanistic sense. These reminds me of Martin Heidegger's statement : "Architecture belongs to poetry, and its purpose is to help man to dwell."

  • PDF

An Exploration of Theory and Methodology in Landscape Architectural Criticism (조경비평의 이론과 방법론 모색)

  • 배정환;조정송
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.21 no.3
    • /
    • pp.35-49
    • /
    • 1993
  • The purpose of this study is to establish some concepts, objects, and methodologies which are essential components in the theoretical inquiry of Landscape Architectural Criticism(LAC), and to explore the structure of LAC. Theough comparing the artistic characteristics of landscape architecture with the latent criticism in it, and introducing some important concepts of criticism and aesthetics, the concept of LAC is defined operationally. And through grasping changes of the definitions and concepts about landscpae architecture, and classifying the fields of it which are related to critical structure, the objects of LAC are established. According to Virgil C. Aldrich and many other aestheticians, general aspects of criticism are divided into $\circled1$analysis, $\circled2$ evaluation, $\circled3$interpretation, and $\circled4$description. Through these aspects and Wayne Attoe's opinion(which seemed to be generalized in architectural), the pertinent methodologies of LAC are explored.

  • PDF

Function of Microclimate Amelioration by Urban Greenspace (도시녹지에 의한 미기후개선의 기능)

  • 조현길;안태원
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.4
    • /
    • pp.23-28
    • /
    • 1999
  • This study measured transpiration rate of urban trees and albedos of urban surfaces, and examined the function of microclimate amelioration by urban greenspace. Transpiration rates of trees were highest in July and August of growing months. Transpiration per unit leaf area for the two months was 300-350 g/$m^2$/h for Platanus occidentalis, 210-270 g/$m^2$/h for Ginkgo biloba and Zelkova serrata, and 130-140 g/$m^2$/h for Acer palmatum. Surface albedos were 0.09 for asphalt paving and 0.68 for white wall, which reveals that light-colored surfaces are better than dark-colored ones to lower the heat build-up. Due to lack of evapotranspiration, concrete surfaces were, at t midafternoon maximum, 8$^{\circ}C$ hotter than grass ones, though the albedo of concrete paving was higher thant that of grass and trees. Summer air temperatures at places with 12% and 22% cover of woody plants were, respectively, 0.6$^{\circ}C$ and 1.4$^{\circ}C$ cooler than a place with no vegetation. To mitigate the impacts of urban heat islands, required are minimization of hard surfaces, light-coloring for building surfaces, and greenspace enlargement including more plantings.

  • PDF

Estimating the Air Temperature Cooling Effect of the Cheonggyechun Stream Restoration Project of Seoul, Korea

  • Park Chong-Hwa;Kwon Young-Sang
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.120-129
    • /
    • 2004
  • Urban stream restoration projects can improve water quality, wildlife habitats, urban landscape, outdoor recreation spaces, and urban microclimate. The objectives of this research were to investigate temperature cooling effect of urban streams by using satellite imagery, to evaluate environmental variables related to stream cooling effect, and to estimate the cooling effect of the Cheonggye stream restoration project of Seoul, Korea. Findings of this research can be summarized as follows. First, a method of estimating temperature distribution around urban streams by using satellite imagery was developed. Scatter plots of distance from stream edges and average temperature obtained through multiple buffering were used for the estimation. Second, urban temperature cooling effect of streams was estimated by comparing background temperature and temperature of each buffer zone. Third, environmental factors affecting stream cooling effect were also identified. Fourth, the temperature cooling effect of the restoration project was estimated based on three scenarios. An estimated cooling effect based on the average cooling effect of existing tributaries showed the most significant effect; $2.0^{\circ}C$ lower than the present level at the edge of the renovated stream. It was estimated that the temperature of the same area would be $1.4^{\circ}C$ cooler than the present level if the cooling effect of the Yangjaechun was used as the bench mark But the effect would be $1.2^{\circ}C$ lower than the present level if environmental variables related to the temperature cooling effect of urban streams were used as the bench mark.

  • PDF

A Case Study of Software Architecture Design by Applying the Quality Attribute-Driven Design Method (품질속성 기반 설계방법을 적용한 소프트웨어 아키텍처 설계 사례연구)

  • Suh, Yong-Suk;Hong, Seok-Boong;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.121-130
    • /
    • 2007
  • in a software development, the design or architecture prior to implementing the software is essential for the success. This paper presents a case that we successfully designed a software architecture of radiation monitoring system (RMS) for HANARO research reactor currently operating in KAERI by applying the quality attribute-driven design method which is modified from the attribute-driven design (ADD) introduced by Bass[1]. The quality attribute-driven design method consists of following procedures: eliciting functionality and quality requirements of system as architecture drivers, selecting tactics to satisfy the drivers, determining architectures based on the tactics, and implementing and validating the architectures. The availability, maintainability, and interchangeability were elicited as duality requirements, hot-standby dual servers and weak-coupled modulization were selected as tactics, and client-server structure and object-oriented data processing structure were determined at architectures for the RMS. The architecture was implemented using Adroit which is a commercial off-the-shelf software tool and was validated based on performing the function-oriented testing. We found that the design method in this paper is an efficient method for a project which has constraints such as low budget and short period of development time. The architecture will be reused for the development of other RMS in KAERI. Further works are necessary to quantitatively evaluate the architecture.