• Title/Summary/Keyword: C-ring test

Search Result 146, Processing Time 0.028 seconds

Prediction of Ring Deflection GRP Pipe Buried Underground (지중매설 GRP 관의 관변형 예측)

  • Kim, Sun-Hee;Lee, Young-Geun;Joo, Hyung-Jung;Jung, Nam-Jin;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.38-44
    • /
    • 2013
  • Glass fiber reinforced plastic (GRP) pipes buried underground are attractive for use in harsh environments, such as for the collection and transmission of liquids which are abrasive and/or corrosive. In this paper, we present the result of investigation pertaining to the structural behavior of GRP flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, experimental and analytical studies are conducted. In addition, vertical ring deflection is measured by the field test and finite element analysis (FEA) is also conducted to simulate behavior of GRP pipe buried underground. Based on the results from the finite element analyses considering soil-pipe interaction the vertical ring deflection behavior of buried GRP pipe is predicted. In addition, analytical and experimental results are compared and discussed.

Study on the Thermal Degradation Behavior of FKM O-rings

  • Lee, Jin Hyok;Bae, Jong Woo;Choi, Myoung Chan;Yoon, Yoo-Mi;Park, Sung Han;Jo, Nam-Ju
    • Elastomers and Composites
    • /
    • v.53 no.4
    • /
    • pp.213-219
    • /
    • 2018
  • The degradation mechanism and physical properties of an FKM O-ring were observed with thermal aging in this experiment. From X-ray photoelectron spectroscopy (XPS) analysis, we could observe carbon (285 eV), fluoro (688 eV), and oxygen (531 eV) peaks. Before thermal aging, the concentration of fluoro atoms was 51.23%, which decreased to 8.29% after thermal aging. The concentration of oxygen atoms increased from 3.16% to 20.39%. Under thermal aging, the FKM O-ring exhibited debonding of the fluoro-bond by oxidation. Analysis of the C1s, O1s, and F1s peaks revealed that the degradation reaction usually occurred at the C-F, C-F2, and C-F3 bonds, and generated a carboxyl group (-COOH) by oxidation. Due to the debonding reaction and decreasing mobility, the glass transition temperature of the FKM O-ring increased from $-15.91^{\circ}C$ to $-13.79^{\circ}C$. From the intermittent CSR test, the initial sealing force was 2,149.6 N, which decreased to 1,156.2 N after thermal aging. Thus, under thermal aging, the sealing force decreased to 46.2%, compared with its initial state. This phenomenon was caused by the debonding reaction and decreasing mobility of the FKM O-ring. The S-S curve exhibited a 50% increase in modulus, with break at a low strain and stress state. This was also attributed to the decreasing mobility due to thermal aging degradation.

Effect of Sealant Materials on Oxygen Permeation in Perovskite Oxide Membrane (밀봉 재료에 따른 페롭스카이트 막의 산소투과 특성)

  • Kim, Jong Pyo;Park, Jung Hoon;Yoon, Yeoil
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.382-387
    • /
    • 2008
  • $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ oxide was synthesized by polymerized complex method. Dense membrane of perovskite oxide was prepared using as-prepared powder by pressing and sintering at $1080^{\circ}C$. Leakage test was conducted on the membrane sealed by gold ring, Pyrex ring or Pyrex powder as a sealing material. The oxygen permeation flux of $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membrane increased with increasing temperature and was $0.74mL/min{\cdot}cm^2$ at $900^{\circ}C$. In the case of the membrane applied by sealing material, oxygen permeation flux of the membrane using gold ring at $950^{\circ}C$ was higher than that using Pyrex materials because the undesired spreading of Pyrex glass materials in the membrane led to the reduction of effective permeation area. Microphotograph analysis results for the membrane after permeation test confirmedthe diffusion of Pyrex glass seal into the membrane.

Determination of metabolites of prostanozol in human urine by LC/ESI/MS and GC/TOF-MS (LC/ESI/MS와 GC/TOF-MS를 이용한 인체뇨시료에서의 Prostanozol 대사체 검출)

  • Yum, Tae-Woo;Paeng, Ki-Jung;Kim, Yun-Je
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.173-182
    • /
    • 2011
  • This research examined prostanozol and its metabolites in urine of women who took the medicine (prostanozol). Prostanozol and its metabolites were successfully separated and detected by using LC/ESI/MS and GC/TOF-MS. Mass spectrum of LC/ESI/MS estimated molecular weight of Prostanozol and its metabolites and that of GC/TOF-MS verified them. For M1, carbon number 17 of Prostanozol substituted to a keto group and it is called 17-keto-Prostanozol. M2 turned out to be hydroxy-17-keto-Prostanozol. It came from substitution of one hydroxyl group of pyrazole nucleus and A-ring of M1. Substitution of one hydroxyl group of B-ring or C-ring became M3, hydroxy-17-keto-Prostanozol. M4 was found to be a hydroxy-17-keto-Prostsnozol transposed from one hydroxyl group to a D-ring. M5 has a hydroxyl group of carbon number 17. One hydroxyl group is substituted from B-ring or C-ring and it is assumed to be hydroxy-17-hydroxy-Prostanozol. M6 was turned out to be dihydroxy-17-keto-Prostanozol transposed from one hydroxyl group to pyrazole nucleus or A-ring and to B-ring or C-ring. Like M6, M7 has a keto group at carbon number 17 and was identified as dihydroxy-17-keto-Prostanozol. M7 has one hydroxyl group at pyrazole nucleus or A-ring and also at D-ring. At last M8 was found to be dihydroxy-17-hydroxy-Prostanozol. Pyrazole nucleus or A-ring has got one hydroxyl group and other rings were substituted to another hydroxyl group. From above, M5, M7 and M8 were verified as new metabolites that were not discovered yet. Prostanozol and all of the 8 metabolites formed glucuronic conjugates as a result of conjugation reaction test in human body. Some of 8 metabolites were excreted without forming conjugates. Particularly M6 and M7 were excreted as sulfate conjugates.

A Study on Objective Diagnosis of constitutions by Laser Stimulation and O-Ring Measurement Systems of Muscular Meridians (레이저 자극과 O-Ring 경근 측정시스템에 의한 체질진단의 객관화에 관한 연구)

  • Kim, Y.Y.;Kim, J.M.;Lee, E.W.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.173-178
    • /
    • 1995
  • This paper relates the occidental constitutional theory to the oriental one, concluding their origins to be similar, and demonstrates a new method of constitutional diagnosis by O-Ring Measurement System Of Muscular Meridians and Laser Constitutional Diagnosis. It establishes Laser Constitutional Diagnosis(L.C.D) using laser beams according to the principles of acupuncture and Sa-Sang constitutional physiology under the effect of spatial morphological energy of geometric isomers. Finally, hypothetical theory of L.C.D. was experimented by the O-Ring Measurement Systems of Muscular Meridians(O-R MSMM). O-R MSMM has been specially devised to improve the manual O-Ring Test prevailing to distinguish energetic response by muscle tonicity. Statistically, it has been proved that the constitutional diagnosis with O-R MSMM was highly effective and objective in the clinical experiences.

  • PDF

A Study Development of the Powder Metallurgy Method Using 400 Series Ferrite Stainless Steel ABS Sensor Ring (분말야금법을 이용한 400계열 페라이트 스테인레스강 ABS 센서 링 개발에 관한 연구)

  • 양현수
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.4
    • /
    • pp.197-208
    • /
    • 2000
  • ABS sensor ring has been manufactured by powder metallurgy (P/M) method using 400 series ferrite stainless steel. The results are following. It is supposedly sufficient to use for control computer due to good experimental results of magnetic characteristics. Compared with sensor ring made by iron, 400 series ferrite stainless steel has shown a good corrosion resistance without an addition surface treatment. Thus the decreasing production process has been obtained. As a result mechanical characteristics of hardness and tensile test, 400 series ferrite stainless steel shown a good endurance when it is combined to constant velocity joint(C/V), and has a good hardness properties endurable to sand and pebble impact. The products before sintering are much more corrodible in the condition of spray test of salt water and ammonia than humidity and nitrogen condition.

  • PDF

Evaluation of HIC/SSCC Resistance for API-X70 Pipe Manufactured by JCO Bending Process and SA Welding (JCO 밴딩과 SA용접으로 제조된 API-X70급 강관의 HIC/SSCC 저항성 평가)

  • Ryoo, Hoi-Soo;Kim, Hee Jin;Lee, Dong-Eon
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.1-6
    • /
    • 2014
  • This study aims at manufacturing SA welded API-X70 line-pipe with sour gas resistance. A pipe was manufactured by JCO bending process and SA welding using the API-X70 plate guaranteed HIC resistance. SA welded pipe was expanded in order to reduce the residual stress. The evaluation of a pipe for resistance to HIC and SSCC were performed by the RS D 0004 and RS D 0005 standards. For verification that a pipe has acceptable resistance to HIC, fullscale test was carried out. Results showed no cracking for the HIC and SSCC.

A Study on Ferrite Stainless Steel Corrosion Resistance or Mechanical Characteristics of 434LD2 ABS Sensor Ring (센서 링이 내식성과 기계적 특성에 관한 연구)

  • 양현수;금영준;정풍기
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.1
    • /
    • pp.129-141
    • /
    • 2003
  • In this thesis, using the 400 series ferrite stainless steel such as 434LD$_2$ which are furter excellent then the existing ferric products in mechanical characteristics, and experiment has been conducted on corrosion resistance of sensor ring. The results are following. 1. The products before sintering are much more corrodible in the condition of spray test of salt water and ammonia than humidity and nitrogen condition. 2. 434LD$_2$ ferrite stainless steel has shown a good corrosion resistance without an addition surface treatment. thus the decreasing production process has been obtained. 3. As hardness value of $H_{RB}$ 80 and tensile test, 434LD$_2$ ferrite stainless steel with show a good endurance when it is combined to constant velocity joint (c/v joint), and has a good hardness properties endurable to sand and pebble impact.

Setting Estimation of Cement Paste Using New-type Embedded Sensor (매입형 센서를 활용한 시멘트 풀의 응결 시간 측정)

  • Shin, Kyung-Joon;Lee, Do-Keun;Seo, Dong-Wan;Yoo, Chul-Min;Lim, Min-Hyuk;Lim, Sung-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.483-488
    • /
    • 2016
  • The present study proposes an economical embedded ring-sensor that can measure a strain behavior of cement paste and mortar in early age. Using the proposed ring-sensor, the experimental method is proposed that can measure the setting time of the cement paste and mortar conveniently. The experimental study has been conducted using the mixtures of which W/C are 0.30, 0.35, 0.40, and 0.45. From the test result, the setting times measured by convectional test methods such as vicat method and penetration resistance method are compared with the setting time proposed by this study. The result reveals that the proposed ring-sensor can effectively measure the early age behavior so that can evaluate the time when the contraction starts. In addition, the contraction starting time can be regarded as a rational setting time, which is similar to the initial setting of convectional test methods.

Friction Characteristics of Warm a Forging Lubricant Containing Nano Graphite Powder (나노분말이 함유된 온간단조용 윤활제 마찰특성)

  • Kim, D.W.;Kim, Y.R.;Lee, G.A.;Choi, H.J.;Yun, D.J.;Shin, Y.C.;Lee, J.K.;Lim, S.J.
    • Transactions of Materials Processing
    • /
    • v.21 no.1
    • /
    • pp.13-18
    • /
    • 2012
  • During warm forging, materials are formed in the temperature range of $300^{\circ}C\sim900^{\circ}C$. In this temperature range, the friction between the forging die and the material is very high and has a negative effect on the forming process causing severe die wear and possible defects in the component because of stick-slip. Thus, lubrication characteristics are a very important factor for productivity during warm forging. In this paper, ring compression experiments were conducted to estimate the friction factor between the die and the materials as the main factor in characterizing the lubricant. Also, ring tests using normal graphite power as a lubricant coating system were compared with tests using nano graphite powder. The results confirm that the nano graphite is superior to the normal graphite in view of its lubricating effect. In addition, the friction factor (m) was estimated with respect to the amount of the nano graphite content in the lubricant. With 10 % nano graphite the friction factor had the lowest value as compared to other amounts. It can be concluded that the amount of the nano graphite in the coating system can be optimized to obtain the best lubrication condition between the die and the material using ring test experiments.