• Title/Summary/Keyword: C-line

Search Result 4,683, Processing Time 0.03 seconds

Experimental Studies on the Performance of the Active Phased-Array. Antenna Coupled by Transmission Line (전송선로로 결합된 능동 위상차배열 안테나의 동작특성에 관한 실험적 연구)

  • 최영규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.175-181
    • /
    • 2004
  • In order to increase the coupling efficiency of the Power and Phase of the active Phase way antenna, we have fabricated the active phased-array antenna which is coupled by the transmission line, and investigated the relationship between the length of the coupling transmission line and coupling power and phase. The following three types of driving method -(1) giving the frequency difference between the two active antenna, (2) applying the input signal to the one side of the two antennas, and changing the eigen frequency of the other side antenna, (3) appling the different phase inputs to the active antennas was investigated. The experimental results showed that the interval of the antenna elements has not affected the power and the phase of the antenna.

A study on the transmission system realization using residential power line carrier (전등선 반송방식 통신시스템 실현에 관한 연구)

  • Kim, In-Soo;Oh, Won-Rock;Kim, Kwan-Ho;Oh, Sang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.707-711
    • /
    • 1989
  • This system exchange half-duplex serial data at 1200 baud by FSK modulating a carrier frequency at 200KHz over the 110V A.C. power line. Transmitter output voltage to A.C. line is 4V p-p and line sensitivity is selected 2.54mV because CISPR Noise limitation is $66dB{\mu}V$ at 150 ${\sim}$ 500KHz. The designed and realized system has abtained system margin of 58 dB and probability of error, Pe = $1.78{\times}10^{-7}$ was obtained

  • PDF

Insulation Aging Properties of Off-Line and On-Line High Voltage Motor Stator (정지중 및 운전중 고압전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1694-1696
    • /
    • 2001
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in six 6.6kV motors. These tests were conducted using a conventional partial discharge detector (PDD), turbine generator analyzer(TGA) and partial discharge analyzer(PDA). Off-line PD measurements were performed on six 6.6kV motors. PD magnitudes ranged from 740 pC to 5,100 pC at the normal line-to-ground voltage. Six 6.6kV motors have been equipped with eighteen 80pF epoxy-mica couplers(one per phase) on the motor terminal boxs. The PD pulse from sensors were measured with the TGA and PDA instruments on a normally operating motors. The PDD, TGA and PDA test results showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

Estimation and Measurement of the Traction return current on the electrified Gyeongbu line.

  • Kim, Y.K.;Yang, D.C.;Han, M.S.;Ryu, C.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.99.5-99
    • /
    • 2001
  • This study presents a simulation of the traction return current based on $2{\times}25kV$ power supply system in order to determine the impedance bond intensity of impulse type track circuit on the electrified Gyeongbu line. The results of the simulation enables us to measure the precise intensity of catenary current that returns to the substation through KTX (Korean Train Express) operated by $2{\times}25kV$ power supply system with common earth network. The combination of $2{\times}25kV$ and common earth network established on the electrified Gyeongbu line for the first time in Korea. We show that the relationships among the traction return current, earth current, and catenary current, and catenary current can be applied to this line in order to determine the optimal impedance bond intensity ...

  • PDF

Signal line potential variation analysis and modeling due to switching noise in CMOS integrated circuits (CMOS 집적회로에서 스위칭 노이즈에 의한 신호선의 전압변동 해석 및 모델링)

  • 박영준;김용주;어영선;정주영;권오경
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.7
    • /
    • pp.11-19
    • /
    • 1998
  • A signal line potential variation due to the delta-I noise was physically investigated in CMOS integrated circuits. An equivalent circuit for the noise analysis was presented. The signal line was modeled as segmented RC-lumped circuits with the ground noise. Then the equivalent circuit was mathematically analyzed. Therebvy a new signal line potential variation model due to the switching mosie was developed. Th emodel was verified with 0.35.mu.m CMOS deivce model parameters. The model has an excellent agreement with HSPICE simulation. Thus the proposed model can be dirctly employed in the industry to design the high-performance integrted circuit design as well as integrated circuit package design.

  • PDF

Integrated Control System of SCARA Robot Based on Off-Line Programming (오프라인 프로그래밍을 이용한 스카라 로봇의 통합제어 시스템 설계)

  • 정경규
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.188-193
    • /
    • 2000
  • We developed a Off-Line Graphic Simulator which can simulate a robot model in 3D graphics space in Windows 95 version. 4 axes SCARA robot was adopted as an objective model. Forward kinematics, inverse kinematics and robot dynamics modeling were included in the developed program. The interface between users and the off-line program system in the Windows 95' graphic user interface i\environment was also studied. The developing language is Microsoft Visual C++. Graphic libraries, OpenGL, y Silicon Graphics, Inc. were utilized for 3D graphics.

  • PDF

Integrated Control System Design of SCARA Robot Based on Off-Line Programming (오프라인 프로그래밍을 이용한 스카라 로봇의 통합제어 시스템 설계)

  • 정동연;한성현
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.11 no.3
    • /
    • pp.21-27
    • /
    • 2002
  • We developed a Off-Line Graphic Simulator which can simulate a robot model in 3D graphics space in Windows 95 version. 4 ares SCARA robot was adopted as an objective model. Forward kinematics, inverse kinematics and robot dynamics modeling were included in the developed program. The interface between users and the off-line program system in the Windows 95's graphic user interface environment was also studied. The developing language is Microsoft Visual C++. Graphic libraries, OpenGL, by Silicon Graphics, Inc. were utilized for 3D graphics.

  • PDF

Electromagnetic Behavior of High -$T_c$ Superconductors underthequenchstate -

  • 정동철;최효상;황종선;윤기웅;한병성
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.183-187
    • /
    • 2002
  • In this paper we analyzed the electromagnetic behavior of high $-T_{c}$ superconductor under the quench state using finite element method. Poisson equation was used in finite element analysis as a governing equation and was solved using algebra equation using Gallerkin method. We first investigate d the electromagnetic behavior of U-type superconductor. Finally we applied our analysis techniques to 5.5 kVA meander-line superconducting fault current limiters (SFCL) which are currently developed by many power-system researcher in the world. Meshes of 14,600 elements were used in analysis of this SFCL. Analysis results show that the distribution of current density was concentrated to inner curvature in meander-line type-superconductors and maximum current density 14.61 $A/\m^2$ and also maximum Joule heat was 6,420 W/㎥. We concluded that this meander line-type SFCL was not pertinet fur uniform electromagnetic field distribution.n.

  • PDF

A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line (송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션)

  • Han, S.W.;Cho, H.G.;Woo, B.C.;Jung, G.C.;Lee, D.I.;Choi, I.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF

Developement of On-Line System for Vibration Signal Analysis (진동신호 분석을 위한 On-Line 시스템 개발)

  • Kim, O.S.;Rim, S.J.;Kim, Y.S.;Lee, Y.G.;Kim, J.C.;Chung, C.S.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF