• 제목/요약/키워드: C-implant

검색결과 474건 처리시간 0.027초

백서에서 치아회분말과 치과용 연석고의 혼합매식술에 관한 실험적 연구;혼합 비율에 따른 비교 (THE EXPERIMENTAL STUDY OF IMPLANTATION COMBINED WITH TOOTHASH AND PLASTER OF PARIS IN THE RATS;COMPARISON ACCORDING TO THE MIXING RATIO)

  • 김영균;여환호;조재오
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권1호
    • /
    • pp.26-32
    • /
    • 1996
  • This study was performed to determine the ideal mixing ratio of toothash and plaster of Paris. The histopathologic and histomorphometric study of bone response of five implant materials, toothash(Group A), tooth and plaster mixture, mixing ratio due to weight 2 : 1(Group B), 3 : 1(Group C), 4 : 1(Group D), and plaster Paris(Group E), were performed in rat calvarial defect. No sign of extensive inflammatory reaction was defected. Newly-formed bony ingrowth occurred in all experimental groups except for group E at 12 weeks after operation. Bone was deposited directly on the surface of implant materials. The highest rate of direct bony union between implant material and newly-formed bone occurred with the group B, followed group C, D, and A.

  • PDF

Effect of Titanium Coating on Cell Adhesion and Extracellular Matrix Formation in Human Osteoblast-like MG-63 Cells

  • Lee, Jae-Bum;Seo, Sang-Hui;Kim, Yu-Ri;Shin, Sang-Wan;Kim, Meyoung-Kon;Ryu, Jae-Jun
    • Molecular & Cellular Toxicology
    • /
    • 제4권3호
    • /
    • pp.192-198
    • /
    • 2008
  • A variety of titanium (Ti) and its alloys are used in the clinical procedures of bone regeneration for periodontal and dental implant therapies. This study was performed to determine the effect of different surface dental implant materials on biologic responses of a MG-63 human osteoblast-like cell line. MG-63 cells were cultured on Ti coated with hydroxyapatite (HA), calcium metaphosphate (CMP), anodized (A), which compared with non-coated Ti (control). The appearances of surface of dental implant materials and the morphology of these cells were assessed by scanning electron microscopy (SEM). The gene expression profiles of MG-63 cells cultured on Ti were examined by human cDNA microarray (1,152 elements). The expression of several genes was up- and down-regulated by different surfaces of dental implant materials. Interesting, the genes correlated with cellular adhesion and extra cellular matrix (ECM) formation were enhanced, in accordance surface morphology of the dental implant materials used.

흰쥐 착상시기에 자궁내 난소 홀몬 수용체와 Prostaglandin 및 cAMP 농도변화에 관한 연구 (Studies on the Concentrations of Receptors for Ovarian Steroids, Prostaglandins and cAMP in Uterine Tissue during the Period of Implantation in Rats)

  • 윤미정;유경자
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제14권1호
    • /
    • pp.43-49
    • /
    • 1987
  • In the present study, hormonal changes in uterine tissue and circulation were evaluated during the implantation period in rats in order to understand the mechanism by which implantation takes place. The results obtained were as follows. 1. Concentrations of serum estradiol and progesterone were significantly increased on days 4 and 5. 2. Concentration of estrogen receptor reached maximum on day 5 when implantation normally occurred in rats. On the other hand, progesterone receptor was gradually decreased, reaching the lowest on day 5. 3. Uterine PGs and cAMP concentrations were significantly increased on day 5. 4. Uterine PGs and cAMP concentrations in implant sites were significantly greater than those in non-implant sites. It is, therefore, concluded that prostaglandins and cAMP in uterine tissue as well as circulating ovarian steroid hormones were increased during the period of implantation, suggesting that these hormones might be actively involved in the process of implantation in rats.

  • PDF

평면구조 P-MOS DRAM 셀의 커패시터 VT 이온주입의 최적화 (Optimization of Capacitor Threshold VT Implantation for Planar P-MOS DRAM Cell)

  • 장성근;김윤장
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.126-129
    • /
    • 2006
  • We investigated an optimized condition of the capacitor threshold voltage implantation(capacitor $V_T$ Implant) in planar P-MOS DRAM Cell. Several samples with different condition of the capacitor $V_T$ Implant were prepared. It appeared that for the capacitor $V_T$ Implant of $BF_2\;2.0{\times}l0^{13}\;cm^{-2}$ 15 KeV, refresh time is three times larger than that of the sample, in which capacitor $V_T$ Implant is in $BF_2\;1.0{\times}l0^{13}\;cm^{-2}$ 15 KeV. Raphael simulation revealed that the lowed maximum electric field and lowed minimum depletion capacitance ($C_{MIN}$) under the capacitor resulted in well refresh characteristics.

Design optimization of the outlet holes for bone crystal growing with bioactive materials in dental implants: Part I. cross-sectional area

  • Lee, Yong Keun;Lee, Kangsoo
    • 한국결정성장학회지
    • /
    • 제23권2호
    • /
    • pp.67-75
    • /
    • 2013
  • In order to improve osseo-integration of a dental implant with bone crystal we studied an implant with holes inside its body to deliver bioactive materials based on a proposed patent. After bioactive material is absorbed, bone crystal can grow into holes to increase implant bonding in addition to surface integration. The larger cross section area of outlet holes showed the less values of the maximum stress, and the stress concentrations near the uppermost outlet holes were also reduced with an increasing number of outlet holes. The conclusion, that the uppermost outlet design improvement was most effective to reduce the stress concentration and improve the growth rate of bone crystal, could be drawn. After the design optimizations, Type 6-C had provided the best results in this study. The overall shape optimization studies on the shape, location, number, and so on, of the outlet holes, should be carried out further.

Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS)

  • 우진오;박봉욱;변준호;김승언;김규천;박봉수;김종렬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권1호
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

타이타늄 표면 처리 특성에 따른 젖음성에 관한 연구 (Wettability of titanium implants depending upon surface properties)

  • 한영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.12-20
    • /
    • 2009
  • 연구목적: 임플란트가 식립되어질 때 매식체는 조직액과 접촉하게 된다. 임플란트의 조직액 흡착은 표면처리에 따라 다양하게 나타난다. 이 때 임플란트 시편의 표면 거칠기와 젖음성과의 상관관계를 분석하고자 하였다. 연구재료 및 방법: 표면 거칠기와 젖음성의 상관관계를 측정하기 위해 네 종류의 임플란트 시편을 각각 5종류 만들었다. 각각의 그룹은 그룹 A: Machined Surface, 그룹 B: Anodized surface, 그룹 C: RBM (HA blasting) surface, 그룹 D: CMP (calcium methaphosphate) coating surface이다. 연구결과: 1. 표면의 거칠기는 RBM, CMP, Anodized, Machined 그룹 순서로 거칠었다. RBM과 CMP는 통계적으로 유의차가 없었다 (P<.05). 2. 젖음성은 Anodized, RBM, CMP, Machined 그룹 순서로 높았다. CMP와 Machined는 통계적으로 유의차가 없었다 (P<.05). 3. 표면 거칠기와 젖음성과의 상관관계는 없었다.

치과 임플란트 고정체의 여러 가지 제조공정과정에 따른 표면특성 (Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process)

  • 정용훈;문영필;이충환;유진우;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.17-24
    • /
    • 2010
  • In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias

  • Park, Kyung-Soon;Al Awamleh, Abdel Ghani Ibrahim;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.73-78
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.

Simultaneous placement of an interpositional free gingival graft with nonsubmerged implant placement

  • Sohn, Joo-Yeon;Park, Jung-Chul;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • 제44권2호
    • /
    • pp.94-99
    • /
    • 2014
  • Purpose: Various surgical techniques target achieving adequate keratinized tissue around dental implants; however, these techniques are usually performed before implant placement or upon the exposure of submerged implants. The aim of this case report is to describe a simultaneous placement of an interpositional free gingival graft (iFGG) with that of nonsubmerged implants in a patient lacking keratinized tissue and to assess the longterm outcome of this grafted gingiva. Methods: A wedge-shaped free gingnival graft (FGG), including an epithelium-connective tissue (E-C) portion and a connective-tissue-only (CT) portion, was harvested from the palate. The CT portion was inserted under the buccal flap, and the E-C portion was secured tightly around the implants and to the lingual flap. Results: At the 8-year follow-up, the gingival graft remained firmly attached and was well maintained, with no conspicuous shrinkage or reported discomfort during oral hygiene procedures. The use of an iFGG at a nonsubmerged implant placement minimizes the required number of surgical steps and patient discomfort while providing adequate buccal keratinized tissue. Conclusions: Therefore, the technique could be considered an alternative method in increasing the keratinized tissue for cases that have a minimal amount of keratinized tissue.