• 제목/요약/키워드: C-flux

검색결과 1,783건 처리시간 0.025초

Development and Validation of Hourly Based Sim-CYCLE Fine in a Temperate C3//C4 Coexisting Grassland

  • Lee, G.Z.;Lee, P.Z.;Kim, W.S;Oikawa, T.
    • The Korean Journal of Ecology
    • /
    • 제28권6호
    • /
    • pp.353-363
    • /
    • 2005
  • We developed a local-scale ecophysiological model, Sim-CYCLE Fine by modifying Sim-CYCLE which was developed for a global scale simulation. Sim-CYCLE fine is able to simulate not only carbon fluxes but also plant growth with various time-steps from an hour to a month. The model outputs of $CO_2$ flux and biomass/LAI were highly reliable; we validated the model results with measurements from the eddy covariance technique and the harvest method ($R^2$ values of around 0.9 for both). The results suggested that the phonology and the seasonal dynamics of the $C_3/C4$ plant communities affected significantly the carbon fluxes and the plant growth during the plant growing season.

INVESTIGATING THE PULSAR WIND NEBULA 3C 58 USING EMISSION MODELS

  • Kim, Seungjong;Park, Jaegeun;An, Hongjun
    • 천문학회지
    • /
    • 제52권5호
    • /
    • pp.173-180
    • /
    • 2019
  • We present IR flux density measurements, models of the broadband SED, and results of SED modeling for the Pulsar Wind Nebula (PWN) 3C 58. We find that the Herschel flux density seems to be slightly lower than suggested by interpolation of previous measurements in nearby wavebands, implying that there may be multiple electron populations in 3C 58. We model the SED using a simple stationary one-zone and a more realistic time-evolving multi-zone scenario. The latter includes variations of flow properties in the PWN (injected energy, magnetic field, and bulk speed), radiative energy losses, adiabatic expansion, and diffusion, similar to previous PWN models. From the modeling, we find that a PWN age of 2900-5400 yrs is preferred and that there may be excess emission at ${\sim}10^{11}Hz$. The latter may imply multiple populations of electrons in the PWN.

고라니(Hydropotes inermis)의 분변이 습지 토양의 CO2 flux에 미치는 영향 (Study on effect on CO2 flux of wetland soil by feces of Korean water deer(Hydropotes inermis))

  • 박효민;전승훈;이상돈
    • 한국습지학회지
    • /
    • 제17권3호
    • /
    • pp.283-292
    • /
    • 2015
  • 토양으로부터 방출되는 $CO_2$의 양은 전 지구적 지구 탄소 순환에서 가장 큰 방출 중 하나로 알려져 있다. 특히 토양 내 미생물의 유기물질 분해 과정에 의해 방출되는 이산화탄소의 양은 토양의 탄소 저장량을 장기적으로 결정하는 요인이 되므로 그 양을 정량화 하는 것이 필요하다. 본 연구는 토양에서 고라니의 분변이 $CO_2$ 배출에 미치는 영향을 파악하기 위해 수행하였다. 그리고 고라니의 분변이 토양의 $CO_2$ 배출에 주는 영향과 토지의 이용에 따라 변화하는 $CO_2$ flux를 정량화 하였다. 그 결과 고라니 분변 내 많은 유기물질은 토양 미생물의 활성화에 영향을 주고 그로 인해 토양의 호흡 및 토양 내 물리 화학적인 변화가 발생되어 토양의 유기물 함량이 서로 다르게 나타남을 확인할 수 있었다. 특히 4개 지역의 토양(경작지, 휴경지, 버드나무 군락, 갈대습지)의 C/N ratio와 $CO_2$ flux는 분변의 유무와 통계적으로 매우 유의미한 상관 관계를 나타냈으며(P<0.01), 분변의 영향을 받은 토양의 $CO_2$ flux는 분변의 영향을 받지 않은 토양보다 2-20배 더 높은 것으로 나타났다. 이 연구는 고라니의 분변이 토양에 주는 영향과 야생동물 분변을 이용한 토양 물질 순환 연구를 통해 육상 생태계 및 토양권의 물질 순환과 그 영향의 정도를 정량화 하였다는 점에서 큰 의의가 있는 연구이다.

수평원관내 $CO_2$의 증발열전달 (Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube)

  • 경남수;장승일;최선묵;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Germanium-based pinning dopants for MgB2 bulk superconductors

  • Chung, K.C.;Ranot, M.;Shinde, K.P.;Oh, Y.S.;Kang, S.H.;Jang, S.H.;Hwang, D.Y.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권2호
    • /
    • pp.36-39
    • /
    • 2019
  • Effects of the spherically shaped Ge and the rod-like carbon-coated Ge on the superconducting properties of $MgB_2$ were investigated. Pure Ge and carbon-coated Ge nano-powders were synthesized under the different amount of $CH_4$ (0 to 5 kPa) by using DC thermal plasma method. When the $CH_4$ was added ~100 nm sized Ge with a spherical shape changed to rod-like morphology with a diameter of ~30-70 nm and a length of ~400-500 nm. Also it was confirmed that thin carbon layers of a few nanometers were formed along the rod length and the agglomerated carbons were found on the edges of rods. Pure spherical Ge and Ge/C rods were mixed and milled with Mg & B precursor to form the doped $MgB_2$ bulk samples by the solid-state reaction method. Almost no change of $T_c$ was noticed for the pure Ge-added $MgB_2$, whereas $T_c$ was found to decrease with the Ge/C-added $MgB_2$ samples. It was found that the pure spherical Ge showed to have a negative effect on the flux pinning of $MgB_2$. However, Ge/C rods can enhance the flux pinning property of $J_c$ due to the coated carbon on Ge rods.

kW급 풍력 발전기 설계 (Design of a kW-class PM Generators for Wind Turbine)

  • 이수호;김거화;원정현;김동언;박현철;정진화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.179.2-179.2
    • /
    • 2010
  • This research has been performed to provide fundamental design aspects of Permanent Magnet Synchronous Generators(PMSGs) for a kilowatt class wind turbine. When it comes to kilowatt class wind turbines, the typical type of generators are Axial Flux Permanent Magnet(AFPM) generators. However, Radial Flux Permanent Magnet(RFPM) generators have been optimally designed to study the output characteristics of a kilowatt class wind turbine in Graduate School of Wind Energy, POSTECH. An existing squirrel-cage rotor has been modified for another newly designed permanent magnet rotor to utilize the commercially existing stator rotor. Electromagnetic analysis utilizing Finite Element Methods tools(ANSYS, MAXWELL 2D) has been applied to analyze the system.

  • PDF

자화인덕턴스 변화를 고려한 약계자 영역에서의 유도전동기 벡터제어 (Vector Control of an Induction Motor for the Field Weakening Region Considering the Variation of Magnetizing Inductance)

  • 이택기
    • 조명전기설비학회논문지
    • /
    • 제13권2호
    • /
    • pp.39-45
    • /
    • 1999
  • 약계자 영역에서 토크는 자속에 직접적으로 영향을 받는다. 이 영역에서는 자속준위는 회전자 속도에 대하여 반비례로 감소시킨다. 자속이 감소함에 따라 자화인덕턴스는 증가하게 된다. 자회인덕턴스는 전류를 제어하기 위한 접압을 제한한다. 본 노문에서는 약계자 영역에서 q-축전압을 측정함으로써 자화인덕턴스의 변화를 계산하며, 이에 따라 기준 자화전류를 재조정한다. 컴퓨터 시뮬레이션 실험결과를 통하여 제안한 방법을 입증한다. 본 연구에서 제안한 알고리즘은 방적기계등의 적용분야의 가변속 구동시스템에 활용이 기대된다.

  • PDF

A Novel Direct Torque Control of Induction Motor

  • Park J. H.;Lee K. J.;Choi J. W.;Kim H. G.;Chun T. W.;Nho E. C.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.423-427
    • /
    • 2001
  • This paper describes a control scheme for direct torque and flux control of Induction machines using space vector modulation. The proposed predictive flux control scheme has directly calculated the reference voltage space vector based on Stator flux errors in order to control the torque and flux. This proposed control scheme has not the requirement of a separate current error, thereby improving transient performance and also has the advantage of less torque ripple in steady state with a fixed switching period. The effect of proposed method has been proven by simulations. It is concluded that the proposed control topology produces better results for steady state operation than the classical direct torque control.

  • PDF

침지형 막모듈에서 중공사 분산에 따른 여과특성 (Filtration Characteristics according to Hollow Fiber Dispersion in Submerged Membrane Module)

  • 이재인;신춘환
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.173-176
    • /
    • 2000
  • This study was carried out to investigate the filtration characteristics of membrane modules according to hollow fiber dispersion for direct solid-liquid separation of activated sludge. 2 bundle, 4 bundle, and 10 bundle, and 10 bundle module used in this experiment according to hollow fiber dispersion was manufactured at laboratory and permeate flux and transmembrane pressure(TMP) of each module were observed under a suction pressure of 0.5kgf/c$m^2$. As the hollow fibers were dispersed, permeate flux was increased and TMP was decreased. Permeate flux and TMP of each module was 15.0 $\ell$/$m^2$.h and 31.8 cmHg for 2 bundle, 16.0 $\ell$/$m^2$ .h and 17.4 cmHg for 4 bundle, and 20.4 $\ell$/m2 .h and 31.8 cmHg for 10 bundle. In conclusion, the membrane fouling is expected to be decrease by maintaining lower TMP with hollow fiber dispersion.

  • PDF

코발트기 자융성합금 코팅의 마모특성에 미치는 후열처리의 영향 (Effect of Post Heat Treatment on Wear Characteristics of Thermally Sprayed Co-based Self-flux Alloy Coating)

  • 이재홍;김영식
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.106-111
    • /
    • 2014
  • This article describes effect of post heat treatment on wear characteristics of thermally sprayed Co-based self-flux alloy coating. Co-based self-flux alloy coatings were deposited on steel substrates using a flame spray process. Post heat treatments were carried out at 800, 900, 1000 and $1100^{\circ}C$ for 30min in a vacuum chamber. For analysis of effect of post heat treatment on mechanical properties, wear test and hardness test were performed for post heat-treated coating specimen. Microstructures of heat treated coating layer and wear track were examined using SEM and EDS. Wear loss and hardness became lower with increasing post heat treatment temperature.