• 제목/요약/키워드: C-V method

검색결과 2,845건 처리시간 0.034초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

수산화칼슘이 손상치수조직 및 치근조직의 치유에 미치는 영향에 관한 연구 (AN EXPERIMENTAL STUDY ON THE EFFECT OF Ca(OH)2 UPON THE HEALING PROCESS OF THE PULP AND PERIAPICAL TISSUE IN THE DOGS' TEETH)

  • 임성상;김영해;이정식;이명종;윤수한;권혁춘;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.123-131
    • /
    • 1982
  • The purpose of this study was to observe the responses of the remaining pulp tissue after pulpotomy upon the several kinds of $Ca(OH)_2$ products and the responses of periapical tissue upon some root canal filling materials after extirpation. For pulpotomy, the class V cavities were prepared on the premolars, molars and upper canines, and the pulp was amputated. Each drug was placed over the amputated tissue and cavity was sealed with zinc oxide eugenol cement. The drugs which were used for the study were Dycal (Caulk Co. U.S.A.), Cavitec (Kerr Co. U.S.A.), Calvital, Nobudyne and Neodyne (Neo Dental Chemical Products). For extirpation, the endodontic cavities were prepared on the lingual surfaces of anterior teeth, and the pulp tissues were extirpated as routine method. After enlarging, irrigation, and measuring of root length by taking X-ray, each root canal filling material was filled in the canal with gutta percha cone, and endodontic cavity was sealed with zinc oxide eugenol cement. Zinc oxide eugenol, $Ca(OH)_2$ (Eli Lilly Co. U.S.A.) and Vitapex (Neo Dental Chemical Products) were used as root canal filling materials. Animals were sacrificed after 1, 3 and 6 weeks following the operation. The teeth were decalcified in formic acid, sectioned and stained with hematoxylin eosin. Microscopic examination revealed as follows. 1. Dycal: The dentin bridge formation was observed at the 3rd week after pulpotomy. Inflammatory conditions which were infiltration of inflammatory cells and dilatation of blood vessels were kept in remaining pulp tissue at the 6th week. 2. Calvital: The dentin bridge was observed at the 1st week after pulpotomy. As the time clasped, the pulp tended to be the fibrous degeneration. 3. Cavitec, Nobudyne and Neodyne: In the case of Cavitec and Nobudyne, the incompleted and irregular dentin bridge was observed at the 6th week, and in Neodyne, was observed at the 3rd week. The severe inflammatory changes were seen in the remaining pulp tissue. As the time clasped, the fibrous degeneration tended to spread in the remaining pulp tissue. 4. $Ca(OH)_2$: Osteocementum was formed at the 3rd week, the matrix of cementum and dentin were resorted, and infiltration of lymphocytes was seen in periapical tissue when $Ca(OH)_2$ was used as canal-filling materials. S. ZOE and Vitapex The cementum like substance was seen in periapical portion at the 1st week, when ZOE and Vitapex were used as root canal filling materials. As the time elapsed, the matrix of cementum and dentin tended to be resorted. At the 6th week, the inflammatory condition of periapical tissue was continued in the case of ZOE, but was reduced in the case of Vitapex.

  • PDF

직장암의 수술 후 방사선치료의 성적 - 예후 인자와 전체 치료기간이 미치는 영향에 관한 고찰 - (Results of Postoperative Radiation Therapy of Rectal Cancers - with the Emphasis of the Overall Treatment Time -)

  • 김주영;이명학;이규찬
    • Radiation Oncology Journal
    • /
    • 제16권3호
    • /
    • pp.303-310
    • /
    • 1998
  • 목적 : 국소적으로 진행된 직장암의 방사선치료에 있어 전통적인 치료방법으로 알려져 있는 근치적 수술 및 보조 방사선 및 항암치료의 성적을 알아보고 이에 영향을 미치는 예후 인자를 알아보기 위함이다. 대상 및 방법 : 1989년 7월 부터 1993년 12월 까지 항문상방 15 cm 이내에 존재하는 직장암으로 진단받고 근치적 수술을 받은 71명의 환자를 대상으로 후향적 분석을 시행하였다. 방사선치료는 6 MeV 선형가속기를 사용하여 주5회씩 5040 cGy 까지 조사되였고 수술후 21일에서 94일 사이에 시작되었고 5-FU와 ACNU chemotherapy가 4주 간격으로 시행되었다. 결과 : 전체환자의 5년 생존율과 5년 무병생존율은 각각 58.8$\%$및 57$\%$였다. 대상환자들의 2년 국소제어율은 76.6$\%$였다. 생존기간 및 무병생존기간의 중앙값은 각각 30개월 및 27개월이었다. 단변량 및 다변량분석시 무병생존율에 의미있게 예후인자로 작용했던 요인은 국소림프절로의 전이여부, 4개 이상의 임파선 전이, 6주이상의 수술과 방사선치료 시작 사이의 간격 및 7일 이상 지속되는 방사선치료 도중의 휴식기간 등이었다. 결론 : 국소적으로 진행된 직장암의 경우 근치적 수술 및 방사선치료 및 5-FU/ACNU를 기본으로 한 항암제를 시행하였을 때 B3 이상의 병기에서는 아직도 생존율이 저조하며 bowel wall penetration이 있거나 국소 림프절전이가 있을 때는 국소제어율도 환자의 절반 정도에서 밖에 얻을 수 없을 뿐만이 아니라 림프절전이가 없는 경우라도 원격전이율이 치료실패의 많은 부분을 차지함을 알 수 있었다. 이는 좀더 효과적인 항암치료제의 선택과 투여 방법이 방사선치료와 병행될 필요가 있음을 시사하며 수술 후 보조적인 방사선치료를 시행함에 있어서 방사선치료가 시작되는 기간이 지연될 때, 또 방사선치료가 7일 이상 중단될 때 치료결과에 영향을 줄 수 있음을 보여준다. 직장선암의 경우 수술과 방사선치료시작까지의 기간이 필요이상으로 연장되거나 치료중 휴식기간이 생겨 전체치료기간이 길어지지 않게 하여야 할 것이다.

  • PDF

스피루리나 첨가 요구르트의 품질 특성 및 항산화능 (Quality Characteristics and Antioxidant Activity of Spirulina added Yogurt)

  • 신유미;손찬욱;심현정;김민희;김미연;권오윤;김미리
    • 한국식품조리과학회지
    • /
    • 제24권1호
    • /
    • pp.68-75
    • /
    • 2008
  • 스피루리나 고유의 색과 냄새로 인한 관능적 품질 저하를 개선하고, 영양성이 풍부하고 기능성이 뛰어난 스피루리나 첨가 요구르트를 개발하기 위하여 우유와 탈지분유에 스피루리나를 0%, 0.25%, 0.5%, 1%의 농도로 첨가하여 $40^{\circ}C$에서 12시간 발효시킨 후 키위퓨레와 올리고당을 첨가하여 요구르트를 제조한 후 스피루리나 첨가량에 따른 이화학적, 미생물학적, 관능적 특성 및 기능성을 측정하였다. 스피루리나 첨가 농도가 높아질수록 pH 감소와 적정산도의 증가폭이 커졌으며, 점도 역시 스피루리나 첨가 농도가 증가할 수록 높아졌다. 생균수는 대조구가 $5.8{\times}10^8$ CFU/mL, 스피루리나 0.25%. 0.5%, 1% 첨가구가 각각 $6.3{\times}10^8$ CFU/mL, $1.5{\times}10^9$ CFU/mL, $3.4{\times}10^9$ CFU/mL로 스피루리나 첨가 농도가 높을수록 생균수가 증가하는 경향을 보였다. DPPH radical소거능 및 Hydroxyl radical 소거능에 대한 항산화 활성 역시 스피루리나 첨가량이 증가할수록 높아지는 경향을 보였다. 또한 7점 척도법으로 관능검사 실시 결과 대조구가 4.7점, 스피루리나 0.25%, 0.5%, 1% 첨가구가 각각 5.2점, 4.0점, 3.7점으로 스피루리나 0.25% 첨가구의 기호도가 가장 높았다. 또는 시판제품과의 순위법 검사에서 스피루리나 0.25% 농도의 첨가구가 3위를 나타내 비교적 높은 기호도를 보였다. 요구르트의 영양성분을 분석한 결과 스피루리나 첨가구는 대조구에 비해 일반성분 중 열량, 탄수화물, 수분, 조회분, 조단백질은 유의적으로 높아졌다. 또한 무기질 중 Na, K, P, Fe, Mg, Cu, Zn, Al이 유의적으로 높아졌으며 Cd, Pb, Hg 등의 중금속은 검출되지 않았다. 이상과 같이 스피루리나를 0.25% 첨가하여 요구르트를 제조할 때 유산균의 생육 및 산 생성을 촉진시켰으며, 요구르트의 관능적인 면에서도 좋은 결과를 보였다. 따라서 여러 가지 유용한 생리 활성을 가지는 스피루리나는 새로운 기능성 요구르트의 개발에 있어서 좋은 천연물 소재로서의 가능성을 가지고 있다고 사료된다.

휴대용 포도자동결속기 개발연구 (Development of the paper bagging machine for grapes)

  • 박광호;이영철;문병우
    • 현장농수산연구지
    • /
    • 제11권1호
    • /
    • pp.79-94
    • /
    • 2009
  • 본 연구는 우리나라 식용포도 재배농가의 보호봉지 결속작업이 주로 고령의 부녀자에 의존하고 있어 향후 이들 노동력을 대체하기 위하여 기계적인 포도보호봉지 결속장치를 개발하여 생산비를 절감하고자 얻어진 결과 는 다음과 같다. 1. 포도 보호봉지 및 포장봉지 결속기 개발 가. 자동결속기 설계는 CATIA V12/AUTOCAD 2000으로 하였다. 나. 자동결속기는 포도보호봉지를 기계적으로 묶어주는 장치로 소형, 경량이어야 하며 작업 시간, 노동량을 줄어 젊은층에서부터 고령자까지 작업할 수 있도록 설계하였다. 다. 자동결속기의 총 무게는 350g이하 초경량으로 제작될 수 있도록 하였다. 라. 결속성공률은 99%이상이 되도록 하였다. 마. 자동결속기의 결속롤과 커터, 배터리, 모터 등의 구조를 스테플러와 같은 가트리지형태로 개발하였다. 바. 카트리지 핀은 C-ring 28mm형으로써 길이는 500mm정도로 포도보호봉지 및 제과·제빵포장봉지를 결속할 수 있도록 제작하였다. 사. 작업시 포도나무 포도넝쿨 등 장애물의 영향을 받지 않도록 디자인을 설계, 제작하였다. 2. 포도보호봉지 결속작업시스템 포장실증시험 가. 자동결속기 시작기를 이용한 포도 보호 봉지결속으로 시기별 과병장, 과식품질이 무처리에 비하여 현저히 높았다. 나. 포도보호봉지 결속작업은 숙련자의 경우 1일 3,000개내외 씌우는 반면 초보자는 1,200개(37%)정도로 크게 떨어졌다. 다. 포도 보호봉지 자동결속기를 이용한 작업효율성은 102%로써 숙련자의 노동력을 대체할 수 있을 것으로 판단되었다. ∘ 1단계 : 232.5%(앞치마에서 보호봉지를 꺼내어 포도에 씌움) ∘ 2단계 : 60.7%(씌운 보호봉지 주름을 잡음) ∘ 3단계 : 104.7%(주름이 잡힌 상태에서 결속) ∘ 4단계 : 102% 라. 포도 보호봉지 결속부위의 둘레(크기)를 조사한 바 관행보호봉지결속작업(수작업)에서는 손으로 철사핀을 감기 때문에 평균 4.6cm이었으며 자동결속기의 결속롤(핀)은 5.3cm가 되어 다소 줄이는 것이 정밀성이 높을 것으로 판단되었다. 마. 수확시 과실 품질(과중, 과방크기-과장, 과폭, 가용성고형물, 산함량)을 조사한 결과 처리한 차이가 인정되지 않았다. 바. 자동결속기를 이용한 포도보호봉지 결속작업처리에서 포도의 열과(터진포도)와 이병율 차이에는 관행방법과 차이가 없었다.

젖소분뇨 반 건식 혐기소화 잔재물의 고체연료화 가능성 평가 (Evaluation of Solidified Fuel Value of Dairy Cattle Manure Digested by Semi-Dry Anaerobic Digestion Method)

  • 정광화;김중곤;이동준;조원모;;곽정훈
    • 유기물자원화
    • /
    • 제24권4호
    • /
    • pp.95-103
    • /
    • 2016
  • 본 연구는 젖소분뇨를 원료로 하여 반 건식 혐기소화 방법을 적용하였을 경우의 혐기소화 가능성을 분석하고 혐기소화 과정에서 배출되는 젖소분뇨 혐기소화 잔재물의 고체연료로서의 가치를 평가하기 위하여 수행되었다. 젖소분뇨의 반 건식 혐기소화 가능성을 평가하기 위하여 950 mL 용량의 반응조를 제작하여 회분식 혐기소화를 실시하였다. 이와 동시에 젖소분뇨 혐기소화 원료를 가로 1,000 mm, 세로 450 mm 크기의 기밀형 아크릴 반응조에 투입하고 항온실에서 중온 혐기소화를 실시한 후에 배출되는 혐기소화 잔재물을 고체연료화 실험원료로 사용하였다. 혐기소화 기질로 사용된 젖소분뇨의 수분함량은 80.64%였으며 젖소분뇨에 첨가한 식종액의 수분함량은 96.83% 수준이었다. 젖소분뇨를 혐기소화하기 위하여 젖소분뇨와 식종액을 1:1 비율로 혼합하였을 때의 수분함량과 VS/TS(휘발성 고형물/총고형물) 함량은 89.74%와 83.35% 수준이었다. 이 젖소분뇨를 혐기소화 한 결과 식종액을 혼합하였을 때 바이오가스가 생성된 반면에 식종액을 혼합하지 않은 경우에는 바이오 가스가 거의 발생되지 않았다. 반 건식 혐기소화를 거친 젖소분뇨 혐기소화 잔재물은 신선분에 비해 열량가가 약 20% 정도 감소하였다. 반면에 회분은 15%에서 18.4%로 증가하였다. 젖소분뇨 혐기소화 잔재물울 고체연료 형태로 펠릿화하였을 경우 크롬과 납, 카드뮴, 황 등의 농도가 규제 수준보다 낮았다. 따라서 젖소분뇨를 혐기소화 하여 바이오가스를 회수하고 난후 혐기소화 잔재물을 고체연료화하여 연료로 활용하는 방법을 적용할 수 있을 것으로 판단된다.

세라믹 표면의 감성 평가 연구: 촉감과 시각적 촉감의 비교를 중심으로 (A Study on Sensibility Evaluation of Ceramic Surface: Comparison between Tactility and Visual Tactility)

  • 김지현;송민정
    • 감성과학
    • /
    • 제19권2호
    • /
    • pp.101-112
    • /
    • 2016
  • 제품은 사용된 소재에 따라 이미지가 달라지며 전달되는 감성 또한 다르게 느껴지기 때문에 적절한 소재의 선정은 매우 중요하다. 세라믹 제품의 표면에 사용되는 소재는 유약과 소지가 있으며 각각이 가진 속성뿐만 아니라 둘의 조합에 따라서도 표면의 촉감과 색상이 달라진다. 본 연구에서는 감성어휘를 통한 평가 방법을 활용하여 세라믹 표면에 대한 시 촉각적 감성을 알아보고 시각을 활용한 촉감 감성과 촉각을 활용한 촉감 감성을 비교하고자 한다. 국내외 유명 세라믹 제품 기업의 홈페이지에 나타난 제품의 마케팅 어휘 중 감성과 관련된 어휘를 중심으로 수집하여 총 13개의 대표어휘를 선정하였으며 소재의 색상 및 균일도, 광택의 유무에 따라 3개의 유약과 4개의 소지를 조합하여 총 12개의 자극물을 제작하였다. 촉각을 활용한 실험에서는 응답자(그룹T)가 제시된 자극물을 문지르기, 만지기, 들어보기의 행동을 거쳐 감성을 평가하였다. 시각을 활용한 실험에서는 촉감 평가에서 유의미한 차이가 나타나지 않은 자극물 3개를 제외한 9개로 평가를 진행하였으며 응답자(그룹V)는 촉각을 활용하지 않고 눈으로 보는 행동만으로 감성을 평가하였다. 촉각을 활용한 감성평가(그룹T)에서 가장 높은 감성 수치를 보인 표면은 백자와 투명유의 조합에 대한 '순수한' 감성이었으며 가장 낮은 감성 수치를 보인 표면은 흑토와 투명유의 조합에 대한 '순수한' 감성으로 나타났다. 한편 시각을 활용한 감성평가(그룹V)에서 가장 높은 감성 수치를 보인 표면도 그룹T와 마찬가지로 백자와 투명유의 조합에 대한 '순수한' 감성으로 나타났으며 가장 낮은 감성 수치를 보인 표면은 흑토와 청자유의 조합에 대한 '캐주얼한' 감성으로 나타났다. 두 그룹의 비교결과 촉각을 통한 감성과 시각을 통한 감성이 모두 유사하게 나타나지는 않으나, '예술적인', '고급스러운', '감각적인', '낭만적인', '신비로운' 감성에서는 시각을 활용하여 촉각을 통한 감성 경험이 가능한 것으로 나타났다.

비인두암의 국소 종양 치유와 생존율에 관한 예후 인자 분석 (An Analysis on Factors Affecting Local Control and Survival in Nasopharvngeal Carcinoma)

  • 정웅기;조재식;박승진;이재홍;안성자;남택근;최 찬;노영희;나병식
    • Radiation Oncology Journal
    • /
    • 제17권2호
    • /
    • pp.91-99
    • /
    • 1999
  • 목적 :비인두암 환자에서 항암화학요법과 방사선치료 후 국소종양제어율, 생졸율, 무병생존율에 미치는 예후 인자를 알아보고자 하였다. 대상 및 방법 : 1986년 7월부터 1996년 6월까지 약 10년간 전남대학교병원에서 비인두암으로 확진되어 근치적 목적으로 치료를 받은 47명의 환자를 대상으로 후향적 분석을 시행하였다. 대상 환자의 연령 분포는 16세에서 80세까지였고 중앙값은 52세였다. 성별 분포는 남자가 33명(70$\%$), 여자가 14명(30$\%$)이었다. WHO의 기준에 의한 조직학적 유형은 제1형(제라틴형성 편평세포암)이 3례(6$\%$), 제2형(비케라틴형성 편평세포암)이 30례(64$\%$), 제3형(미분화암)이 13례(28$\%$)였고 나머지 1례(2$\%$)는 조직학적 유형이 알려지지 않았다. 미국암합동위원회(1997)의 병기분류법에 따라 후향적으로 다시 분류한 병기는 71, T2a, T2b, 73, 74에서 각각 11례(23$\%$), 6례(13$\%$), 9례(19$\%$), 7례(15$\%$), 14례(30$\%$)였다. 그리고 림프절 침범 상태는 NO, Nl, N2, N3에서 각각 7례(15$\%$), 14례(30$\%$), 21례(45$\%$), 5례(l0$\%$,) 있었다. 병기군별 분포는 Stage 1, IIA, IIB, III, IVA, IVB에서 각각 2례(4$\%$), 2례(4$\%$), 10례(21$\%$), 14례(30$\%$), 14례(30$\%$), 5례(11$\%$) 있었다. 방사선치료 전에 항암제 치료를 받은 환자는 42례이며 5례는 항암제 치료가 시행되지 않았다. 방사선치료는 선형가속기의 6MV와 10MV X-ray 및 9MeV 전자선을 사용하였으며 원발 병소에 조사된 총방사선량은 6120-7920cGy(중앙값 : 7020cGy)였다. 항암화학요법 은 Cisplatin+5-Fluorouracii(25명), Cispiatin+pepleomycin(17명)으로 1회에서 3회까지 시행하였다. 국소종양제어율, 생졸율, 무병생존율을 Haplan-Meier법에 의하여 산출하였으며 두 군간의 생존율의 차이는 GeneraliBed t띤cokon test를 이용하여 검증하였다. 영향을 주는 인자의 다변량분석에는 Cox 모델을 이용하였다. 결과 : 국소종양 제어율은 2년에 89$\%$, 5년에 81$\%$이었다. 5년 생존율을 60$\%$,(범위: 6-132개월, 중앙값: 106개월)이었다. 예후에 영향을 미치는 위험 일자로 연렬, 성별, 뇌신경침범, 병리조직학적 유형, 병기군, 항암화학요법, 항암화학 요법과 방사선치료 사리의 간격, 방사선량, 방사선치료기간을 다변량분석에 포함시켰다. 국소종양제어율에는 뇌신경침범(P=0.004)만이 의의 있는 것으로 나타났다. 생존율과 무병생존율에는 병기군(P=0.006, P=0.006)과 총방사선량 (P=0.012, P=0.008)이 의의 있는 것으로 나타났다. 치료 후 합병증은 구강건조증, 치아손상, 이증상 등이 많았으며 2례의 갑상선기능저하증이 있었다. 결론 : 비인두암에서 예후에 영향을 미치는 인자로서 국소종양제어율은 뇌신경침범 여부가, 생존율 및 무병생존율에는 총방사선량과 병기군, 특히 N 병기가 의의 있는 것을 알 수 있었다. 사용된 항암화학요법과 방사선치료는 심각한 부작용이 없이 효과적으로 이용될 수 있음을 알 수 있었다.

  • PDF

미세조작된 생쥐수정란의 초급속 재동결융해 후 생존성 (Viabilities of Biopsied Mouse Embryos after Ultrarapid Refreezing and Thawing)

  • 신상태;임준호;강만종;한용만;이경광
    • 한국가축번식학회지
    • /
    • 제20권2호
    • /
    • pp.207-214
    • /
    • 1996
  • 본 연구는 미세조작된 수정란의 초급속 재동결 후 발생능을 조사하기 위해서 수행하였다. 먼저 4세포기 생쥐 수정란으로부터 할구세포 한 개를 떼어내고 이들 수정란을 동결액에 넣어 상온에서 2.5분간 평형시킨 다음, 0.25ml straws에 넣어 곧바로 액체질소에 침지시켰다. 4세포기 수정란의 동결액으로는 4.0M(ethylene glycol 및 0.25M sucrose가 함유된 dPBS를 사용하였따. 상실배기 수정란의 동결을 위해서는 항동해제로 4.0M ethylene glycol 대신에 5.0M glycerol을 사용하였다. 융해후 biopsied 4세포기 수정란을 M16 배양액에서 상실배기까지 발달시킨 다음 상실배기용 동결액을 이용하여 초급속 재동결을 실시하였다. 재동결융해 후 발달한 biopsied 배반포기 수정란을 대리모에 이식하여 이들 수정란의 생존성을 검토하였다. 제1차 동결후 biopsied 수정란의 체외발달률은 78%로서 정상적인 수정란의 발달율(91%) 보다 낮은 성적으로 보여주었으나 (P<0.01), 이들 수정란의 이식 후 임신률은 각각 25 및 30%로서 두 실험군간에 차이가 인정되지 않았다. 그리고 biopside 상실배기 수정란의 초급속 재동결후 체외 발달률 및 임신률은 각각 89와 27%로서 biopsied 되지 않은 수정란의 성적 (각각 95 및 28%)과 유사하였다. 이러한 결과를 종합하여 볼 때, 본 연구에서 사용된 초급된 재동결 과정이 미세조작된 생쥐수정란의 생존성에 영향을 미치지 않는 것으로 나타났다.

  • PDF

이중경화법을 이용한 열개시제 및 광개시제가 배합된 황칠도료의 경화속도 촉진 및 물성향상 연구 (Improving Curing Rate and Physical Properties of Korean Dendropanax Lacquer with Thermal and Photo Initiator by Dual Curing)

  • 황현득;문제익;박초희;김현중;황백
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권4호
    • /
    • pp.333-340
    • /
    • 2010
  • 한반도 남부 일대에서 자생하는 황칠나무(Dendropanax morbifera Lev.) 수액으로부터 추출한 천연 도료인 황칠도료(Korean Dendropanax lacquer)는 예로부터 귀중한 예술품이나 투구, 화살, 활 등의 전쟁도구를 찬란한 황금색으로 도장하는데 사용되어 왔다. 경화 후 황금색의 투명한 도막을 형성하여 우수한 색상특성을 지니고 있을 뿐만 아니라 내후성, 내수성, 내식성 등이 우수하여, 보호도장으로써도 훌륭한 가치를 지니고 있다. 그러나 이러한 많은 장점에도 불구하고, 현대적인 여러 적용분야에 사용되지 못하고 있는 이유는 황칠도료의 생산량이 적고, 이로 인하여 가격이 매우 고가이고, 장시간의 경화시간이 소요되는 문제도 큰 원인으로 작용하고 있다. 한편 황칠 내에 광중합이 가능한 conjugated diene을 포함한 모노머가 있으며, 이러한 모노머는 일광 조사 조건등에 의하여 짧은 시간에 단단하고 황금색을 띠는 도막을 형성할 수 있음이 보고된 바가 있다. 따라서 본 연구에 서는 전통적인 황칠도료의 경화방법을 개선하고 경화속도를 촉진하기 위하여, 열개시제를 도입하여 열경화를 촉진하는 방법과 열개시제 및 광개시제를 동시에 도입하고 이중경화(dual curing)에 의해서 경화속도를 촉진하고자 하였다. 이러한 경화 속도 및 경화 거동은 적외선분광분석기(FT-IR)을 이용하여 -C=C- 이중결합 특성피크의 변화를 관찰하거나, 진자경도계(pendulum hardness tester)를 이용하여 표면 경도의 변화를 관찰함으로써 평가하였다. 또한 강체진자물성측정기(RPT)에 spot UV curing 장비를 도입하여 이중경화에 의한 경화 속도 진을 평가하였다. 본 연구의 결과 열개시제에 의하여 열경화가 촉진될 수 있을 뿐만 아니라, 이중경화에 의하여 경화속도를 향상시킬 수 있음을 확인하였다. 또한 이러한 황칠도료 경화 속도 촉진 방법을 활용하여 전통적인 역에만 사용되어온 황칠도료를 현대적인 여러 적용분야에도 확대하여 사용할 수 있는 가능성을 제시하였다.