• 제목/요약/키워드: C-D Phantom

검색결과 99건 처리시간 0.024초

자궁경부암 방사선치료 시 직장가스 용적 변화에 따른 선량 비교 평가 - Phantom Study (Comparative evaluation of dose according to changes in rectal gas volume during radiation therapy for cervical cancer : Phantom Study)

  • 최소영;김태원;김민수;송흥권;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.89-97
    • /
    • 2021
  • 목 적: 본 연구에서는 자궁경부암 방사선치료 시 전산화치료계획에 없던 직장 내 가스 용적 변화에 따른 선량변화를 비교 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Anderson Research Laboratories Inc, RANDOTM phantom, USA)의 전산화 단층촬영 영상에 전산화치료계획시스템(EclipseTM Treatment Planning System, Varian, Palo Alto, version 15.6, USA)으로 9개의 필드를 이용한 정적 세기조절방사선치료계획(Static Intensity Modulated Radiation Therapy, S-IMRT)과 Full arc로 두 방향의 체적변조회전방사선치료계획(Volumetric Modulated Arc Therapy, VMAT)을 수립하였다. 임의의 가스 변수는 0.5 cm 단위로 2.0 cm까지 변화를 주어 계획표적체적(Planning Target Volume, PTV)에 포함될 수 있도록 하였다. 표적에 대한 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity Index, HI), PTV Dmax를 구하였고, 손상위험장기(Organ At Risk, OAR)에 대한 최소선량(Minimum Dose, Dmin)과 평균선량((Mean Dose, Dmean), 최대선량(Maximum Dose, Dmax)을 계산하여 비교하였다. T-검정을 실시하여 p-value를 구했으며 유의수준은 0.05로 설정하였다. 결 과: S-IMRT와 VMAT의 HI 결정계수(R2)는 0.9423, 0.8223으로 상관관계가 비교적 명확하였고, PTV Dmax 결과 임의의 가스 용적이 커질수록 최대 2.8%까지 증가하는 것으로 나타났다. OAR의 경우 두 전산화치료계획 모두 방광에서 유의한 차이가 없었고, 직장의 경우 +1.0 cm 이상의 가스 용적에서 두 전산화치료계획 모두 Dmean 700 cGy 이상의 유의한 선량 차이가 나타났다. 방광의 Dmean을 제외한 모든 값에서 p-value 0.05 이하로 통계적인 유의한 차이를 확인하였다. 결 론: 기준 전산화치료계획에 없던 가스 발생 시 가스 용적 크기가 커질수록 PTV의 선량 변화와 직장에 전달되는 선량이 증가하였다. 방사선치료 진행 시 직장 가스의 용적이 클 경우 발생 할 수 있는 선량 전달 오류를 최소화하기 위한 노력이 반드시 필요한 것으로 판단되었다. 향후 가스 용적의 다양한 크기와 위치를 변수로 설정하여 추가적인 연구가 진행되어진다면 유익한 평가가 이루어 질 수 있을 것으로 사료된다.

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Hypopharynx Cancer의 VMAT 치료 시 Neck 3D Bolus 적용에 대한 유용성 평가 (The Application of 3D Bolus with Neck in the Treatment of Hypopharynx Cancer in VMAT)

  • 안예찬;김진만;김찬양;김종식;박용철
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.41-52
    • /
    • 2020
  • 목 적: Hypopharynx Cancer의 VMAT 치료 시 Neck 부분에 Commercial Bolus(이하 CB)와 3D Printing 기술로 제작한 3D Bolus를 각각 적용한 두 치료 계획을 비교함으로써 3D Bolus 적용의 선량학적 유용성, setup 재현성 및 효율성을 알아보고 임상적 적용 가능성을 평가하고자 한다. 대상 및 방법: CB를 적용한 RANDO phantom의 CT image를 바탕으로 3D Bolus를 동일한 형태로 제작하였다. 3D Bolus는 OMG SLA 660 Printer, MaterialiseMagics software를 이용하여 SLA기법을 통해 밀도 1.2 g/㎤의 폴리우레탄 아크릴레이트 수지로 출력하였다. CB와 3D Bolus를 적용한 두 CT image를 바탕으로 Hypopharynx Cancer의 VMAT 치료를 가정하여 치료 계획을 수립하였다. 수립한 두 치료 계획을 각각 18회에 걸쳐 CBCT image를 획득하였고, 매 회 setup time을 측정하여 치료 효율성을 평가하였다. 획득한 CBCT image를 바탕으로 전산화 치료계획 시스템 Pinnacle을 통해 Adaptive Plan을 진행함으로써 Target, 정상 장기 선량 평가와 Bolus Volume의 변화를 평가하였다. 결 과: 각 치료 계획에 대한 setup time은 CB 적용 치료 계획에 비해 3D Bolus 적용 치료 계획에서 평균 28 sec 감소하였다. 치료 전 기간 내 Bolus Volume 변화는 CB Initial Plan 83.9㎤에서 86.1±2.70㎤, 3D Bolus Initial Plan 92.2㎤에서 99.8±0.46㎤로 나타났다. CTV Min Value의 변화는 CB Initial Plan 191.6cGy에서 167.4±19.38cGy, 3D Bolus Initial Plan 167.3cGy에서 149.5±18.27cGy로 나타났다. CTV Mean Value의 변화는 CB Initial Plan 227.1cGy에서 228.3±0.38cGy, 3D Bolus Initial Plan 225.9cGy에서 227.7±0.30cGy로 나타났다. PTV Min Value의 변화는 CB Initial Plan 128.5cGy에서 74.9±19.47cGy, 3D Bolus Initial Plan 139.9cGy에서 83.2±12.92cGy로 나타났다. PTV Mean Value의 변화는 CB Initial Plan 225.4cGy에서 226.2±0.83cGy, 3D Bolus Initial Plan 224.1cGy에서 225.8±0.33cGy로 나타났다. 정상 장기 Spinal Cord에 대한 Max Value는 매 회 평균 135.6cGy로 동일하게 나타났다. 결 론: 본 논문의 실험 결과를 통해 불균등한 체표면에 대한 3D Bolus의 적용이 Commercial Bolus 적용에 비해 선량학적으로 유용하고 setup 재현성 및 효율성 또한 우수함을 알 수 있었다. 추후 3D Printing 재료의 다양성에 대한 연구와 함께 추가적인 사례 연구가 진행된다면 방사선 치료 분야에서 3D Bolus의 적용이 더욱 활발하게 진행될 것으로 사료된다.

인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가 (The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy)

  • 김종욱;우헌;정현학;김경아;김찬용;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.329-336
    • /
    • 2014
  • 목 적 : 인공 유방 확대술을 받은 환자가 유방암 방사선치료를 받을 경우 유방의 크기별로 치료 조사야와의 거리에 따른 치료반대 측 유방조직에 피폭되는 선량 및 차폐의 효율성을 평가해 보고자 한다. 대상 및 방법 : 인체팬텀(Rando-phantom)을 이용하여 유방 모형의 크기별 (200 cc ~ 500 cc) CT영상을 획득한 후 크기 별로 일 선량 180 cGy의 왼쪽 유방암 방사선 치료계획을 세웠다. 유방 모형이 커질수록 치료 반대 측 유방모형의 표면과 X선의 진행지점 사이에 발생하는 거리가 가까워지게 설정하였고, 체표에 입사하는 선속중심축을 기준으로 3 cm, 6 cm 떨어진 점에서 반대측 유방 표면에 수직으로 내린 거리를 각 A point, B point로 설정하였다. 그리고 유두지점에서 외측으로 2 cm 되는 점을 C point, 체표중앙에서 외측으로 6 cm 되는 점을 D point로 설정하였다. 유방 모형의 크기별로 각 측정지점에 MOSFET을 부착하여 6 MV, 10 MV, 15 MV의 X선 에너지로 조사하여 측정하였다. 이와 동일한 조건으로 납 2 mm의 두께로 차폐한 후의 선량 값과 납 2 mm 아래에 bolus 3 mm를 부착하여 차폐한 후의 선량 값을 얻었다. 결 과 : 유방 모형이 200 cc에서 500 cc로 커짐에 따라 유방 모형의 표면과 X선의 진행지점과의 거리가 A point에서는 2.14 cm에서 최대 1.23 cm으로 근접하였고 B point에서는 2.55 cm에서 1.31 cm으로 근접하였다. 유방 모형의 크기에 따라 180 cGy 기준으로 200 cc 대비 500 cc의 산란선 측정값이 A point에서 3.22 ~ 4.17%, B point에서 4.06 ~ 6.22%, C point는 0.4~0.5% 증가하였고, D point에서는 크기별로 측정값의 차이가 0.4% 미만이었다. X선 에너지가 커짐에 따라 6 MV 대비 15 MV X선에서 180cGy 기준으로 산란선이 A point에서는 4.06~5%, B point에서는 2.85~4.94%, C point에서는 0.74~1.65% 증가하였고, D point에서는 측정값 차이가 0.4% 미만이었다. 차폐체로 납 2 mm를 사용하였을 경우 A와 B point에서 평균 9.74%, C point에서 2.8%, D point에서 1% 미만의 산란선 감소효과가 있었고, 납과 bolus를 함께 차폐하였을 경우 A와 B point에서 평균 9.76%, C point에서 2.2%, D point에서 1% 미만의 산란선 감소효과가 있었다. 결 론 : 일반적으로 인공 유방 확대술을 받은 환자의 경우 유방의 크기에 따라 치료 반대편 유방 표면과 치료조사야의 거리가 가까울수록 유방 표면이 받는 산란선이 증가하였다. 동일한 크기의 유방 모형에서는 사용 X선 에너지가 커질수록 산란선에 의한 피폭이 증가하는 경향을 보였고, 이는 사용 X선의 에너지 선택에 있어 유방암의 방사선 치료계획에서 허용되는 한도에서는 낮은 X선 에너지의 사용이 반대측 유방의 선량 감소에 유리할 것으로 여겨진다.

The Noise Power Spectrum in Heavy Ion CT Based on Measurement of Residual Range Distribution

  • Yasuda, Naruomi;Abe, Shinji;Nishimura, Katsuyuki;Tomita, Tetsuya;Sato, Hitoshi;Muraishi, Hiroshi;Kanzaki, Takayuki;Inada, Tetsuo;Fujisaki, Tatsuya
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.228-230
    • /
    • 2002
  • The relative electron density resolution was discussed by the noise power spectrum (NPS) in the heavy ion CT image. The heavy ion beam $\^$12/C accelerated up to 400MeV/u by RIMAC was used in this study. The two-dimensional (2-D) NPS in the CT image was obtained from the one-dimensional (1-D) NPS of the measured residual range distribution of water phantom for single projection, and the noise variance in the CT image was calculated from 2-D NPS. The technique used in the reconstruction was the filtered back-projection method with Shepp-Logan filter. The calculated value suggests the result of our previous works using the density resolution phantom, assuming that the relative electron density resolution is twice the standard deviation. Therefore, the estimation of the noise in CT images by 2-D NPS obtained the measured residual range distribution is the useful method.

  • PDF

VMAT를 이용한 유방암 방사선치료 시 반대편 유방의 Bolus 사용에 따른 흡수선량 평가 (Evaluation of Absorbed Dose according to the Use of Bolus in Opposite Breast during Radiation Therapy of Breast Cancer using VMAT)

  • 김종보;신상화
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.763-768
    • /
    • 2018
  • 방사선치료 기법의 발전으로 치료가 더욱 정밀해졌음에도 불구하고 치료 부위 외에도 방사선에 의해 피폭되는 것은 피할 수 없다. 이에 본 연구에서는 유방암의 방사선치료 시 치료 반대편 유방의 bolus 두께에 따른 흡수선량을 평가하고 선량 저감 효과에 대해 분석하고자 하였다. 실험 및 방법으로 Rando phantom을 대상으로 VMAT 치료방법을 이용하여 실험을 진행하였다. 치료 반대편 유방에 A, B, C, D, E의 5개 지점을 선정하여 bolus를 사용하지 않았을 때와 5, 10, 15, 20 mm의 bolus를 사용하였을 때의 선량을 유리선량계를 사용해 평가하였다. 그 결과, 치료지점과 가장 가까운 지점에서 높은 흡수선량이 측정되었으며 치료지점과 가장 먼 B 지점에서는 가장 낮게 측정되었다. 평균 흡수선량은 bolus를 사용하지 않았을 때 8.61 cGy 그리고 두께에 따라 8.10, 7.94, 8.06, 8.10 cGy로 나타났다. 연구 결과 선량 저감 효과를 확인할 수 있었으며, 본 연구를 바탕으로 적절한 bolus 두께를 설정하여 정상조직의 선량 저감화를 위해 노력해야 할 것이다.

유방암 환자의 Field-in-Field Technique 치료 시 호흡의 움직임에 따른 선량 평가 (Evaluation of the Dose According to the Movement of Breath During Field-in-Field Technique Treatment of Breast Cancer Patients)

  • 권경태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.561-566
    • /
    • 2018
  • Field-in-Field Technique is applied to the radiation therapy of breast cancer patients, and it is possible to compensate the difference in breast thickness and deliver uniform dose in the breast. However, there are several fields in the treatment field that result in a more complex dose delivery than a single field dose delivery. If the patient's respiration is irregular during the delivery of the dose by several fields and the change of respiration occurs, the dose distribution in the breast changes. Therefore, based on the computed tomography images of breast cancer patients, a human model was created by using a 3D printer (Builder Extreme 1000) to describe the volume in the same manner. A computerized tomography (CT) of the human body model was performed and a treatment plan of 260 cGy / fx was established using a 6-MV field-in-field technique using a computerized treatment planning system (Eclipse 13.6, Varian, USA). The distribution of the dose in the breast according to the change of the respiration was measured using a moving phantom at 0.1 cm, 0.3 cm, 0.5 cm amplitude, using a MOSOXIDE Silicon Field Effect Transistor (MOSFET, Best Medical, Canada) Were measured and compared. The distribution of dose in the breast according to the change of respiration showed similar value within ${\pm}2%$ in the movement up to 0.3 cm compared to the treatment plan. In this experiment, we found that the dose distribution in the breast due to the change of respiration when the change of respiration was increased was not much different from the treatment plan.

Hemodynamically Induced Aneurysm-mimicking Findings at Anterior Communicating (A-com) Artery Area due to Anatomical Variation on 3D-TOF MRA

  • 강원석;정태섭;심용운;유병규;박인국
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.133-133
    • /
    • 2001
  • Purpose: To determine the relationship between anatomical variation at A-com. artery area an hemodynamically induced aneurysm-mimicking findings on 3D-TOF MRA clinically a experimentally. Method: Sixty-two patients who had no aneurysm at A-com artery on DSA were evalua with MRA. MRA was performed with 1.5T MR machine(Vision, Siemens). Scan parameters o MRA included TR/TE/FA=30/6.4/25$\psi$$\circledR$˙¡, 512*192 of matrix with MIP technique. The occurrence of signal defect at shoulder area of bifurcated A-com artery on MRA was evalua for the relationship between the symmetricity of bilateral ACA and the patency of A-c artery. DSA images were acquired at both ICA and VA. To analyze hemodynamical facto of signal defect, experimental studies of MRA and DSA were peformed with elastic silic phantom using conducting pulsatile pump. We also compared the results with those o computational fluid dynamics(CFD).

  • PDF

컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발 (Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography)

  • 김성현;서태석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF

광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰 (Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry)

  • 김정미;전수동;백금문;조영필;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.123-129
    • /
    • 2010
  • 목 적: 방사선 치료의 선량평가를 위해 사용되는 Optically stimulated luminescent dosimeters (OSLD) 선량 특성을 분석하여, 선량 측정의 유용성을 알아보고자 한다. 대상 및 방법: $NanoDot^{TM}$$Inlight^{TM}$MicroStar Reader, Solid Water Phantom, 의료용 선형가속기 $TRYLOGY^{(R)}$를 사용하였다. 측정 조건은 OSLD를 Solid Water Phantom의 $D_{max}$ 깊이에 위치시킨 후 SSD는 100 cm, Field size는 $10{\times}10\;cm^2$로 하고 300 MU/min으로 6 MV 광자선, 100 cGy의 방사선을 조사하였다. OSLD를 10분 마다 판독하면서 변화값을 측정하였고, OSLD에 선량을 50 cGy와 100 cGy씩 누적시켜 판독하였다. 또한 에너지 의존성은 6 MV, 15 MV, 4~20 MeV를 사용하였다. 선량률은 100~1,000 MU/min로 변화시키면서 측정하였다. 광자선 6 MV의 PDD의 변화를 측정하기 위해 OSLD와 전리함(Ionization chamber) (FC 65P-747)을 사용하였다. 결 과: 시간의 경과에 따른 OSLD의 재현성은 ${\pm}2.5%$였다. OSLD의 선량에 대한 선형성(linearity)을 평가한 결과 300 cGy까지는 선형적으로 증가하였고, 300 cGy 이상에서는 초선형적(supralinearity)으로 증가하였다. 에너지 의존성은 ${\pm}2%$ 이내였고 선량율 의존성은 ${\pm}3%$ 이내였다. 6 MV 광자선에 대하여 OSLD로 측정한 $PDD_{10}$은 66.7%, $PDD_{20}$은 38.4%였고 전리함(Ionization chamber)으로 측정한 $PDD_{10}$은 66.6%, $PDD_{20}$은 38.3%였다. 결 론: OSLD의 특성을 분석한 결과 시간, 에너지, 선량률의 변화에 따른 차이는 ${\pm}3%$ 이내였으며 전리함(Ionization chamber)과 비교한 PDD는 0.3% 이내였다. 또한 300 cGy까지는 선량이 선형적으로 증가하였다. OSLD는 여러 번 반복 측정이 가능하였고 측정과 판독이 용이하여 선량계로서 유용성을 확인하였다.

  • PDF