• Title/Summary/Keyword: C rate

Search Result 19,620, Processing Time 0.047 seconds

Transistorized counting-rate meter (트랜지스터 계수율계)

  • 정만영;박계영
    • 전기의세계
    • /
    • v.15 no.4
    • /
    • pp.18-21
    • /
    • 1966
  • A transistorized counting-rate meter was designed by substituting one of diodes in the ordinary diode pumping circuit by the Darling's constant current source. Its circuit is so simple and stable that it is proper to use as a part of portable radiation detectors. Maximum readable counting rate is well above 100 kc/s and the linearity is very good. Output deviations due to the variations of embient temperatures are less than 5% in the temperatures from 20.deg. C to 40.deg. C.

  • PDF

Thermal Analysis of Tobacco Leaf I. Thermogravimetric and Differential Thermal Analysis (잎담배의 열분석 I. 열중량분석과 시차열분석)

  • Park, Yeong-Su;Yang, Gwang-Gyu
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.3 no.2
    • /
    • pp.89-93
    • /
    • 1981
  • Some or the parameters affecting the thermal analysis of different types of ground tobacco have been discussed. The sample, Korean flue- cured and burley and Greek orient tobacco leaves were run in air at heating rate of $10^{\circ}$ and 20^{\circ}C$ per minute. The thermograms obtained were divided into four temperature zones. The effect of different heating rates on thermal degradation has been discussed At the lower heating rate the maxima of DTA curves in zone 3 and 4 were 25-$40^{\circ}C$ lower than that of the higher heating rate.

  • PDF

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

Chemical Vapor Deposition of $\beta$-SiC by Pyrolysis of MTS and Effect of Excess C Sources (MTS의 열분해를 이용한 $\beta$-SiC의 화학증착 및 Excess C 공급원의 영향)

  • 최병진;박병옥;김대룡
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.1
    • /
    • pp.46-54
    • /
    • 1993
  • $\beta$-SiC was chemically vapor deposited by pyrolysis of MTS+H2 gas mixture. The experiments were conducted in the temperature range of 1100~150$0^{\circ}C$ with a r.f. induction furnace under atmospheric pressure. The IR, XRD, EDS and AES analysis revealed that the free Si was always codeposited with SiC below 140$0^{\circ}C$, regardless of the total flow rate and MTS concentration, whereas $\beta$-SiC single phase was deposited at 150$0^{\circ}C$. C3H8 or CH2Cl2 as an excess C sources, was supplied with MTS in order to obtain stoichiometric SiC at low temperature. With the addition of C3H8 or CH2Cl2, the deposition rate was increased and $\beta$-SiC single phase could be deposited even at temperature as low as 110$0^{\circ}C$. In the absence of C3H8 or CH2Cl2, the microhardness of the layer was quite low (

  • PDF

Effect of Loading Rate on the Deformation Behavior of SA508 Gr.1a Low Alloy Steel and TP316 Stainless Steel Pipe Materials at RT and 316℃ (상온과 316℃에서 SA508 Gr.1a 저합금강 배관과 TP316 스테인리스강 배관의 변형거동에 미치는 하중속도의 영향)

  • Kim, Jin Weon;Choi, Myung Rak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.383-390
    • /
    • 2015
  • This study conducted tensile tests on SA508 Gr.1a low alloy steel and SA312 TP316 stainless steel piping materials under various strain rates at room temperature (RT) and $316^{\circ}C$ to investigate the effects of loading rate on the deformation behavior of nuclear piping materials. At RT, the deformation behavior for both pipe materials showed a typical loading rate dependence, i.e., the strength increased and the ductility decreased as the loading rate increased. At $316^{\circ}C$, however, the strength and elongation of SA508 Gr.1a low alloy steel decreased as the loading rate increased, and its reduction of area non-linearly varied with the loading rate. For SA312 TP316 stainless steel, the strength, elongation, and reduction of area at $316^{\circ}C$ were almost the same regardless of the loading rate. At both temperatures, the strain hardening capacity was nearly independent of the loading rate for SA508 Gr.1a low alloy steel, while it decreased with increasing loading rate for SA312 TP316 stainless steel.

Effects of Water Temperature and Salinity on Dietary Feeding of Manila clam (Ruditapes philippinarum) (바지락, Ruditapes philippinarum의 먹이 섭취에 미치는 수온과 염분의 영향)

  • 김철원;고강희
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2004
  • The feeding, clearance rate, and ingestion rate of Manila clam (Ruditapes philippinarum) were investigated with small group (10.8$\pm$.58 mm in shell length) and large group (37.5$\pm$3.8 mm in shell length) under combination in water temperature (24, 27, 33, $36^{\circ}C$) With salinity (12, 15, 24, 27$\textperthousand$). The maximum feeding, clearance rate, and ingestion rate in small and large groups were $27^{\circ}C$ and 27$\textperthousand$, respectively. While, The minimum feeding, clearance rate, and ingestion rate in both groups were $36^{\circ}C$ and 12$\textperthousand$, respectively. There results were suggested that the feeding, clearance rate, and ingestion rate of Manila clam were significantly influenced by external factors such as water temperature and salinity. The reason for the mass mortality of Manila clam during the heavy rainfall in summer season can be explained by high temperature and low salinity.

A study on the reaction rate and the antioxidant effects of caramelization reaction mixtures (Caramelization 온도별 반응속도와 반응 생성물의 유지에 대한 항산화효과에 관한 연구)

  • 최인덕;안명수
    • Korean journal of food and cookery science
    • /
    • v.11 no.4
    • /
    • pp.396-400
    • /
    • 1995
  • The antioxidant effects in soybean oil was investigated by browning reaction mixtures formed by sugar and reaction temperatures above 110$^{\circ}C$. 0.1 M solution of xylose, glucose and sucrose were heated at 110, 120, 130, 140 and 150$^{\circ}C$ for 24 hrs respectively. A reaction rate constant(k), activation energy (Ea) and Q$\sub$10/ value were determined by color intensity that was measured absorbance at 490 nm in each temperature. Soybean oil containing the ethanol extracts taken from the browning reaction mixtures that were heated at 110, 130 and 150$^{\circ}C$ was stored in an incubator kept at 45.0${\pm}$1.0$^{\circ}C$ for 24 days. The results are as follows: 1. When 0.1 M solution of xylose, glucose and sucrose were heated at 110$^{\circ}C$ and 120$^{\circ}C$, the intensity of glucose browning mixtures was the highest, but heated at 150$^{\circ}C$, the color intensity increased in order of xylose > glucose > sucrose after 24 hrs. 2. The reaction rate constant (k) was increased rapidly above 140$^{\circ}C$ and appeared maximum at 150$^{\circ}C$, esp. xylose was the highest. The activation onergy (Ea) of xylose was the highest as 93.28 Joule/mole and the Q$\sub$10/ value of xylose was appeared 1.28. Q$\sub$10/ value was also the highest in xylose. 3. The browning reaction mixtures that were heated at 110$^{\circ}C$ appeared little antioxidant effects. But, in heated at 130$^{\circ}C$ and 150$^{\circ}C$, the antioxidant effects appeared in sucrose browning reaction mixtures. Therefore, in browning reaction mixtures that heated above 110$^{\circ}C$, only sucrose browning reaction mixtures appeared antioxidant effects and xylose, glucose appeared little antioxidant effects. On the contrary xylose and glucose increased peroxide values of soybean oil.

  • PDF

Electrochemical Performance of Graphite/Silicon/Carbon Composites as Anode Materials for Lithium-ion Batteries (리튬이온배터리 Graphite/Silicon/Carbon 복합 음극소재의 전기화학적 성능)

  • Jo, Yoon Ji;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.320-326
    • /
    • 2018
  • In this study, Graphite/Silicon/Carbon (G/Si/C) composites were synthesized to improve the electrochemical properties of Graphite as an anode material of lithium ion battery. The prepared G/Si/C composites were analyzed by XRD, TGA and SEM. Also the electrochemical performances of G/Si/C composites as the anode were performed by constant current charge/discharge, rate performance, cyclic voltammetry and impedance tests in the electrolyte of $LiPF_6$ dissolved inorganic solvents (EC:DMC:EMC=1:1:1 vol%). Lithium ion battery using G/Si/C electrode showed better characteristics than graphite electrode. It was confirmed that as the silicon content increased, the capacity increased but the capacity retention ratio decreased. Also, it was shown that both the capacity and the rate performances were improved when using the Silicon (${\leq}25{\mu}m$). It is found that in the case of 10 wt% of Silicon (${\leq}25{\mu}m$), G/Si/C composites have the initial discharge capacity of 495 mAh/g, the capacity retention ratio of 89% and the retention rate capability of 80% in 2 C/0.1 C.

Effect of Deposition Parameters on the Property of SiC Layer in TRISO-Coated Particles (TRISO 피복 입자에서 증착 조건이 탄화규소층의 특성에 미치는 영향)

  • Park, J.H.;Kim, W.J.;Park, J.N.;Park, K.H.;Park, J.Y.;Lee, Y.W.
    • Korean Journal of Materials Research
    • /
    • v.17 no.3
    • /
    • pp.160-166
    • /
    • 2007
  • TRISO coatings on $ZrO_{2}$ surrogate kernels were conducted by a fluidized-bed chemical vapor deposition (FBCVD) method. Effects of the deposition temperature and the gas flow rate on the properties of SiC layer were investigated in the TRISO-coated particles. Deposition rate of the SiC layer decreased as the deposition temperature increased in the temperature range of $1460^{\circ}-1550^{\circ}C$. At the deposition temperature of $1550^{\circ}C$ the SiC layer contained an excess carbon, whereas the SiC layers had stoichiometric compositions at $1460^{\circ}C\;and\;1500^{\circ}C$. Hardness and elastic modulus measured by a nanoindentation method were the highest in the SiC layer deposited at $1500^{\circ}C$. The SiC layer deposited at the gas flow rate of 4000 sccm exhibited a high porosity and contained large pores more than $1{\mu}m$, being due to a violent spouting of particles. On the other hand, the SiC layer deposited at 2500 sccm revealed the lowest porosity.

Specific Heat and Thermal Conductivity Measurement of XLPE Insulator and Semiconducting Materials (XLPE 절연층과 반도전층 재료의 비열 및 열전도 측정)

  • Lee Kyoung-Yong;Yang Jong-Seok;Choi Yong-Sung;Park Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.6-10
    • /
    • 2006
  • To improve mean-life and reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconducting materials in 154(kV) underground power transmission cable. Specimens were respectively made of sheet form with EVA, EEA and EBA added $30[wt\%],$ carbon black, and the other was made of sheet form by cutting XLPE insulator in 154(kV) power cable. Specific heat (Cp) and thermal conductivity were measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from $20[^{\circ}C]\;to\;90[^{\circ}C],$ and the heating rate was $1[^{\circ}C/mon].$ And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C]\;and\;90[^{\circ}C].$ In case of semiconducting materials, the measurement temperature ranges of specific heat were from $20[^{\circ}C]\;to\;60[^{\circ}C],$ and the heating rate was $1[^{\circ}C/mon].$ And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C].$ In addition we measured matrix of semiconducting materials to show formation and growth of carbon black in base resins through the SEM. From these experimental results, both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.