Controller Design for Electron Beam Manufacturing System (전자빔 가공기의 제어기 구성)

  • Lim, S.J.;Kang J.H.;Lee C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1862-1865
    • /
    • 2005
  • We have a plan to design a controller for electron beam manufacturing system. At first, we designed a controller for SEM. The controller consists of five parts (power source, beam controller, scanning controller, optic controller and main controller). Beam controller supplies pulse wave for generating high voltage and can monitor the status of high voltage instrument through emission current. Optic controller controls focus, spot size and image shift. Main controller transmits variables from operating program to each part and monitors the status of peripheral device.

  • PDF

A Study on the Inner Defect Inspection for Semiconductor Package by ESPI (ESPI를 이용한 반도체 패키지 내부결함 검사에 관한 연구)

  • Jung, Seung-Tack;Kim, Koung-Suk;Yang, Seung-Pil;Jung, Hyun-Chul;Lee, You-Hwang
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1442-1447
    • /
    • 2003
  • Computer is a very powerful machine which is widely using for data processing, DB construction, peripheral device control, image processing etc. Consequently, many researches and developments have progressed for high performance processing unit, and other devices. Especially, the core units such as semiconductor parts are rapidly growing so that high-integration, high-performance, microminiat turization is possible. The packaging in the semiconductor industry is very important technique to de determine the performance of the system that the semiconductor is used. In this paper, the inspection of the inner defects such as delamination, void, crack, etc. in the semiconductor packages is studied. ESPI which is a non-contact, non-destructive, and full-field inspection method is used for the inner defect inspection and its results are compared with that of C-Scan method.

  • PDF

Characterization of Fiber Direction Influence in CFRP Composites Using Advanced NDE Techniques

  • Im, Kwang-Hee;Jang, Ju-Hwan;Back, Chong-Gui;Jeong, Ok-Su;Hsu, David K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.1003-1007
    • /
    • 2012
  • A nondestructive technique would be very useful. Advanced NDE T-ray (terahertz ray) techniques of technology and instrumentation has provided a probing field on the electromagnetic spectrum. However, the T-ray is limited in order to penetrate a conducting material to some degree. Here, the T-ray would not go through easily the CFRP composite laminates since carbon fibers are electrically conducting while the epoxy matrix is not. So, investigation of terahertz time domain spectroscopy (THz TDS) was made and reflection and transmission configurations were studied for a 48-ply thermoplastic PPS(poly-phenylene sulfide)-based CFRP solid laminate. It is found that the electrical conductivity of CFRP composites depends on the direction of unidirectional fibers.

Development of Image Processing S/W for UT-NDE of Steam Generator of Nuclear Power Plant (핵발전소 증기발생기의 초음파 비파괴 평가를 위한 영상처리 소프트웨어 개발)

  • Lee, Young-Seock
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.217-222
    • /
    • 2006
  • This paper describes a development of ultrasonic examination analysis software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. This software provides the information of shape, depth, size and position of flaws. To do such, we obtain raw data from specimens and/or real pipeline of power plants and, modify the obtained ultrasonic 1-dimensional data according to prepared software design schedule. The developed analysis software is applied to specimens containing various flaws with known dimensions. The results of applications showed that the developed software provided accurate and enhanced images of flaws on various specimens.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

A System Design Method of Mine Warfare Using Information for SONAR and MDV (소나와 무인기뢰처리기 정보를 활용한 기뢰전 체계 설계 방안)

  • Kim, Jun-Young;Shin, Chang-Hong;Kim, Kyung-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.12
    • /
    • pp.1243-1249
    • /
    • 2014
  • The naval mine is the explosives that are installed in the water in order to attack surface ships or submarines. So mine warfare is a very important component of naval operations. In this paper, first, understanding of the general concept about mine warfare. Second, introduce the mine hunting progress and mine sweeping progress. And then, suggest the system design method of mine counter measure warfare using several functions. The functions are mine area detection algorithm for side scan sonar image using Adaboost algorithm, and calculation to mine hunting progress rate and mine sweeping progress rate. And techniques that lead the mine disposal vehicle(MDV) to mine.

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

Fast Motion Estimation Algorithms Through Adaptive Application of the Hadamard Transform (하다마드 변환의 적응적 적용을 이용한 고속 움직임 예측 알고리즘)

  • Lee, Hyuk;Kim, Jong-Ho;Jin, Soon-Jong;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.8C
    • /
    • pp.712-719
    • /
    • 2007
  • In this paper, we propose a new, effective, fast motion estimation algorithms using $4{\times}4$ pixels Hadamard transform. The Hadamard transform has the advantage of simplicity because it uses only addition and subtraction. Motion estimation is composed of three stages. First, it should be decided whether to terminate the search early and use a previous motion vector with DC(Direct Current) coefficients. Then the adaptive matching scan order for motion estimation should be determined according to the image complexity using AC(Alternating Current) coefficients. Experimentally, we adapted this algorithms to MVFAST and PMVFAST algorithms, and the proposed algorithms turn out to be very efficient in terms of computational speed while remaining almost the same in terms of PSNR(Peak Signal-to-Noise Ratio) compared to MVFAST and PMVFAST algorithms.

Low Temperature Sintering Mg-Zn Ferrites (Mg-Zn Ferrites의 저온소결화)

  • Kwon Oh-Heung
    • Resources Recycling
    • /
    • v.12 no.6
    • /
    • pp.8-12
    • /
    • 2003
  • According to the recent trend to raise the horizontal scan frequency to increase the image refinement of the High Definition TV and High Resolution Display, material with low core loss is required for the ferrite core for deflection yoke, which is secured even in the high frequency range. liking notice of the influence on the fine structure of Mg-Zn ferrite by the chemical com position and process, low temperature sintering was proceeded. Cu was added to the low loss Mg-Zn system ferrite. After select-ing MgO, ZnO, $Fe_2$$O_3$, CuO, MgO was substituted for CuO while varying the composition ratio. Then the sample was sintered for 3 hours between $980~1350^{\circ}C$ Magnetic permeability, power consumption, shrinkage rate, core loss were measured. The start-ing temperature to test the shrinkage of the sample was nearby $900^{\circ}C$, it increased according to the substitution process of Cu, and the firing temperature was lowered about $-50~-75^{\circ}C$ alongside of the process.

Design of MRI Spectrometer Using 1 Giga-FLOPS DSP (1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • Purpose : In order to overcome limitations in the existing conventional spectrometer, a new spectrometer with advanced functionalities is designed and implemented. Materials and Methods : We designed a spectrometer using the TMS320C6701 DSP capable of 1 giga floating point operations per second (GFLOPS). The spectrometer can generate continuously varying complicate gradient waveforms by real-time calculation, and select image plane interactively. The designed spectrometer is composed of two parts: one is DSP-based digital control part, and the other is analog part generating gradient and RF waveforms, and performing demodulation of the received RF signal. Each recover board can measure 4 channel FID signals simultaneously for parallel imaging, and provides fast reconstruction using the high speed DSP. Results : The developed spectrometer was installed on a 1.5 Tesla whole body MRI system, and performance was tested by various methods. The accurate phase control required in digital modulation and demodulation was tested, and multi-channel acquisition was examined with phase-array coil imaging. Superior image quality is obtained by the developed spectrometer compared to existing commercial spectrometer especially in the fast spin echo images. Conclusion : Interactive control of the selection planes and real-time generation of gradient waveforms are important functions required for advanced imaging such as spiral scan cardiac imaging. Multi-channel acquisition is also highly demanding for parallel imaging. In this paper a spectrometer having such functionalities is designed and developed using the TMS320C6701 DSP having 1 GFLOPS computational power. Accurate phase control was achieved by the digital modulation and demodulation techniques. Superior image qualities are obtained by the developed spectrometer for various imaging techniques including FSE, GE, and angiography compared to those obtained by the existing commercial spectrometer.

  • PDF