• 제목/요약/키워드: C/R

검색결과 18,256건 처리시간 0.044초

5S와 45S rDNA 유전자를 이용한 제주도산 애기더덕 (Codonopsis minima)과 더덕 (C. lanceolata)의 FISH 패턴 분석 (Analysis of FISH patterns using 5S and 45S rDNAs in Codonopsis minima and C. lanceolata from Jeju Island)

  • 김수영;김찬수
    • 한국약용작물학회지
    • /
    • 제18권3호
    • /
    • pp.186-190
    • /
    • 2010
  • The chromosome number was identified and fluorescence in situ hybridization(FISH) mapping of 5S and 45S rDNAs were conducted for C. minima and C. lanceolata in the genus Codonopsis from Jeju island. In this study, we have confirmed that the somatic metaphase chromosome number determined as 2n=2x=16 was the same as the findings from the previous studies. While the conventional staining method makes it rather difficult to distinguish satellite chromosomes due to high degree of variability, FISH analysis produced the exact number and location of 5S and 45S rDNAs. Both species in the genus Codonopsis have a pair of 5S rDNA and their gene loci were observed on chromosome 3. Although two pairs of 45S rDNAs (one on chromosome 1 and the other on chromosome 8) were identified in both species, the 45S rDNA signals on chromosome 8 in C. minima were significantly weaker than those on chromosome 1. In addition, the 45S rDNA signals on chromosome 1 in C. lanceolata showed that the chromosome is non-homologus. In this study, we have determined cytogenetic characteristics of C. minima and C. lanceolata according to their gene replication patterns.

$C_0(R)$$L^1(R)$의 완전수렴(完全收斂)과 커널밀도함수(密度函數) 추정량(推定量)의 응용(應用)에 대(對)한 연구(硏究) (A Note on Complete Convergence in $C_{0}(R)\;and\;L^{1}(R)$ with Application to Kernel Density Function Estimators)

  • 이성호
    • Journal of the Korean Data and Information Science Society
    • /
    • 제3권1호
    • /
    • pp.25-31
    • /
    • 1992
  • Some results relating to $C_{0}(R)\;and\;L^{1}(R)$ spaces with application to kernel density estimators will be introduced. First, random elements in $C_{0}(R)\;and\;L^{1}(R)$ are discussed. Then, complete convergence limit theorems are given to show that these results can be used in establishing uniformly consistency and $L^{1}$ consistency.

  • PDF

Water Quality Characteristics and Fish Community of the Gucheon Reservoir and Yeoncho Reservoir in Geoge Island

  • Han, Jeong-Ho;Paek, Woon-Kee;An, Kwang-Guk
    • 한국환경생태학회지
    • /
    • 제29권1호
    • /
    • pp.29-45
    • /
    • 2015
  • Water chemistry and fish community, based on fish compositions and ecological characteristics(trophic/tolerance guilds and condition factor), were compared in Gucheon Reservoir($G_cR$) and Yeoncho Reservoir($Y_cR$). Chemical parameters of water quality such as BOD, COD, nutrient(N, P) and suspended solids indicated that water quality was better in the $Y_cR$ than $G_cR$, and the temporal variability in seasonal and interannual patterns were greater in the $Y_cR$. The greater variability was mainly attributed to intense dilutions of reservoir water by Asian monsoon rain during July-August. Fish guild analysis indicated that species diversity was higher in the $G_cR$ than the $Y_cR$, and that the proportion of tolerant and omnivore species were greater in the $Y_cR$. Regression analysis of body weight-total length showed that the regression coefficient(b value) was lower in the $G_cR$(2.15 ~ 2.40) than the $Y_cR$(2.59 ~ 3.14). Condition factor(K) of fish against the total length showed negative slope of Zacco temminckii, Carassius auratus, Pseudorasbora parva and Rhinogobius brunneus population in the $G_cR$, and a positive slope of Carassius auratus and Rhinogobius brunneus population in $Y_cR$. Overall, our data suggest that the growth of the fish populations, based on the length-weight relations and condition factor, reflected the trophic regime of nutrients and organic matter.

비탄성변위비와 붕괴강도비를 이용한 MPA기반의 IDA 해석법 (MPA-based IDA Using the Inelastic Displacement ratio, CR and the Collapse Intensity, RC)

  • 한상환;석승욱;이태섭
    • 한국지진공학회논문집
    • /
    • 제14권5호
    • /
    • pp.33-39
    • /
    • 2010
  • 본 연구는 Modal Pushover Analysis(MPA)를 기반으로 비탄성 변위비(inelastic displacement ratio, $C_R$)와 붕괴 강도비(collapse strength ratio, $R_C$)를 이용한 간략한 Incremental Dynamic Analysis (IDA) 해석법을 제안해 냈다. 이 해석법은 선형 또는 비선형 동적해석 수행 없이 다자유도 시스템의 응답을 계산하기 때문에 간단하게 IDA곡선을 얻을 수 있다. 제안한 방법의 정확성은 6층, 9층, 20층의 철골 모멘트 골조를 대상으로 44개의 지진데이터를 사용하였으며 본 연구에서 제안하는 MPA를 이용한 $C_R-R_C$ IDA 해석결과와 비선형 동적해석 (Nonlinear Response History Analysis)을 통한 IDA 응답값, 그리고 각 주요모드의 비선형 동적해석을 통한 MPA-IDA 응답 값을 비교하여 타당성을 확인하였다. MPA를 이용한 $C_R-R_C$ IDA 해석법은 반복된 비선형 동적해석 과정이 없기 때문에 계산시 소요시간이 가장 작았으며 비교적 정확한 결과를 나타냈다.

마이크로핀관내에서 R-22와 R-4O7C의 응축압력강하 특성에 관한 실험적 연구 (Experimental study for the pressure drop of R-22 and R-4O7C during the condensation in the micro-fin tubes)

  • 노건상
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.715-722
    • /
    • 2007
  • Experiments were conducted for the investigation of pressure drop inside horizontal micro-fin tubes during the condensation of R-22 and ternary refrigerant. R-407C(HFC-32/125/134a 23/25/62 wt%) as a substitute of R-22. The condenser is a double-tube and counterflow type heat exchanger which is consisted with micro-fin tubes having 60 fins with a length of 4000mm, outer diameter of 9.53mm and fin height of 0.2mm. The mass velocity varied from 102.1 to $301.0kg/(m^2{\cdot}s)$ and inlet quality was fixed as 1.0. From the experimental results. the pressure drop for R-407C was considerably higher than that for R-22. The value of PF(penalty factor) for both of refrigerants was not bigger than the ratio of micro-fin tube area to smooth tube area. Based on the experimental data. correlation was Proposed for the prediction of frictional pressure drop during the condensation of R-22 and R-407C inside horizontal micro-fin tubes.

대체냉매 R-407C의 모세관 선정에 관한 연구 (Investigation on the selection of capillary tube for the alternative refrigerant R-407C)

  • 김용환;김창년;박영무
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.56-65
    • /
    • 1998
  • In this paper, experimental investigation of capillary tube performance for R-407C is performed. The experimental setup is made of real vapor-compression refrigerating system. In this study, mass flow rate is measured for capillary tubes of various diameter and length as inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rates of the numerical model are less than by 14% compared with the measured mass flow rates. It is found that mass flow rate and length for R-407c are less than those of R-22 under the same condition. Also based on this experimental study and the numerical model, a set of capillary tube selection charts for R-407C is constructed.

  • PDF

Condensation Heat Transfer of R22, R407C, and R410A in Slit Fin-and-Tube Heat Exchanger

  • Jeon, Chang-Duk;Lee, Jin-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.188-198
    • /
    • 2003
  • R410A and R407C are considered to be alternative refrigerants of R22 for the air-conditioners. An experimental study is carried out to investigate the effect of the change of mass flow rate on the characteristics of heat transfer and pressure drop in three row slit finned-tube heat exchanger for R407C, R410A and R22. R407C, a non-azeotropic refrigerant mixture, exhibited a quite different condensation phenomenon from those of R22 and R410A and its condensation heat transfer coefficient was much lower than that of R22 and R410A. On the other hand, the condensation heat transfer coefficient of R410A, near-azeotropic refrigerant mixture, was a little higher than that of R22. R410A also showed the lowest condensation pressure drop across the test section. For all refrigerants, the condensation heat transfer coefficient and pressure drop increase as the mass flux increases. The condensation heat transfer coefficient correlation proposed by Kedzierski shows the best agreement with the experimental data within $\pm$20%.

방사선조사에 의한 R-C 직.병렬회로에서의 손상효과에 관한 연구 (A Study on Irradiation Effect by $Co^{60}$ of the R-C Series-Parallel Circuits)

  • 서국철;조성욱
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제1권2호
    • /
    • pp.57-61
    • /
    • 1987
  • 원자력 산업에서 사용되고 있는 모든 재료의 특성은 방사선조사에 의한 손상효과로 변하게 된다. 본 연구에서는 저항과 콘덴서의 직.병렬회로에서의 방사선조사에 의한 전기적 특성이 여하히 변화되는가를 연구하였다. 연구결과 얻어진 주요 결론은 다음과 같다. 1. R-C 직렬회로에서 조사선량이 $10^6[r]$까지는 임피던스변화율이 증가되다가 그 이상의 조사선량에서는 포화상태에 이르게 되는데 포화상태에서의 증가율은 1.25[%]정도이었다. 2. R-C 직렬회로에서 조사선량이 $10^6[r]$ 까지는 증가변화율이 감소되다가 그 이상의 조사선량에서는 포화상태에 이르게 되는데 감소율은 0.5[%]정도이었다. 3. R-C 병렬회로에서는 방사선량이 $10^6[r]$까지는 임피던스변화율이 증가되다가 그 이상의 방사선량에서는 포화상태에 이르게 되는데 증가율은 0.5[%]정도이었다. 4. R-C 병렬회로에서는 방사선량이 $10^6[r]$까지는 감소되다가 그 이상의 방사선량에서는 포화상태에 이르게 되는데 감소율은 1.3[%]정도이었다.

  • PDF

대체냉매 R407C 및 R410A를 이용한 슬릿휜-관 열교환기의 응축특성에 관한 연구 (An Experimental Study on Condensation Characteristics of Slit Fin-tube Heat Exchanger Using Alternative Refrigerants, R407C and R410A)

  • 전창덕;장경근;강신형;이진호
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.706-716
    • /
    • 2002
  • R410A and R407C are considered to be alternative refrigerants to R22 for the air-conditioners. Experimental investigation is made to study the condensation heat transfer characteristics of slit fin-tube heat exchanger using alternative refrigerants R410A and R407C. R407C, a non-azeotropic refrigerant mixture, exhibited a quite different condensation phenomenon from those of R22 and R410A and its condensation heat transfer coefficient was much lower than that of R22 and R410A. Between the R22 and R410A, the condensation heat transfer coefficient of R410A, near-azeotropic refrigerant mixture, was a little higher than that of R22. R410A also showed the lowest condensation pressure drop across the test section. For all refrigerants, the condensation heat transfer coefficient and pressure drop increase as the mass flux increases.

GENERALIZED (C, r)-HANKEL OPERATOR AND (R, r)-HANKEL OPERATOR ON GENERAL HILBERT SPACES

  • Jyoti Bhola;Bhawna Gupta
    • 대한수학회논문집
    • /
    • 제38권3호
    • /
    • pp.821-835
    • /
    • 2023
  • Hankel operators and their variants have abundant applications in numerous fields. For a non-zero complex number r, the r-Hankel operators on a Hilbert space 𝓗 define a class of one such variant. This article introduces and explores some properties of two other variants of Hankel operators namely kth-order (C, r)-Hankel operators and kth-order (R, r)-Hankel operators (k ≥ 2) which are closely related to r-Hankel operators in such a way that a kth-order (C, r)-Hankel matrix is formed from rk-Hankel matrix on deleting every consecutive (k - 1) columns after the first column and a kth-order (R, rk)-Hankel matrix is formed from r-Hankel matrix if after the first column, every consecutive (k - 1) columns are deleted. For |r| ≠ 1, the characterizations for the boundedness of these operators are also completely investigated. Finally, an appropriate approach is also presented to extend these matrices to two-way infinite matrices.