• Title/Summary/Keyword: C/R

Search Result 18,256, Processing Time 0.044 seconds

Effects of the Temperature Glide and Superheat of R407C on the Performance of Evaporator (R407C의 온도구배와 과열도가 증발기 성능에 미치는 영향)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.852-859
    • /
    • 2003
  • R407C is considered as an alternative refrigerant of R22 for air conditioners. An experiment was carried out to investigate the characteristics of the evaporation heat transfer and pressure drop for refrigerant R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning unit. The experimental data were useful in analyze the effects of the temperature glide and superheat for R407C. Test were conducted at the conditions of inlet refrigerant evaporation temperature of 7$^{\circ}C$, inlet air relative humidity of 50%, and refrigerant mass fluxes varying from 150 to 250 kg/m$^2$s. Representative results show that the heat exchanger performance for R407C evaporation is significantly affected by the change of the flow pattern from two-phase to super-heated vapor flow.

Behavior of a Hollow R.C Pier Internally Confined by a Steel Tube (강관으로 내부 구속된 중공 R.C 교각의 거동 특성)

  • Kim, Sung-Nam;Han, Taek-Hee;Kang, Young-Jong
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.176-184
    • /
    • 2005
  • When the weight if a concrete member makes problems. or when the cost of the concrete is relatively high, it may be economical to use a hollow concrete member. But a hollow R.C Pier may have poor ductility because of the brittle failure at the inner face of the hollow R.C Pier. This brittle failure results from the absence of the confinement at the inner face of the hollow R.C Pier. To avoid this brittle failure an internally confined hollow R.C Pier was developed. Test results show that the energy ductility ratio of a internally confined hollow R.C Pier have a superior energy ductility ratio to a general hollow R.C Pier.

  • PDF

Prediction of Nucleate Pool Boiling Heat Transfer Coefficients of Ternary Refrigerant R407C

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Chung, Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.93-103
    • /
    • 1998
  • The nucleate boiling heat transfer experiments are performed using a ternary refrigerant R407C which is a candidate of alternatives of HCFC 22. The boiling phenomena of R-32, R-125 and R-134a which are the constituent refrigerants of R407C are also investigated. The nucleate boiling heat transfer coefficients of R407C are less than those of HCFC 22 which have the similar physical and transport properties. In our experimental pressure range, which is similar to the operational pressure of air conditioning system, the deterioration of boiling heat transfer coefficients of mixture refrigerant R407C does not appear for moderate wall superheat region. Since nucleate boiling heat transfer coefficients cannot be obtained from ideal mixing law of mixture, Thome's method was used to predict. To account for the heat flux effect and system pressure in Thome's method, the correcting factor, a(P.L1T), was introduced and obtained from experiments for ternary refrigerant R407C.

  • PDF

A study on prediction of oil concentration in the R-407C and R-410A refrigeration system (대체냉매 R-407C와 R-410A를 사용하는 냉동시스템의 오일농도 예측에 관한 연구)

  • 이종문;김창년;박영무
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.384-390
    • /
    • 1999
  • A vibrating U-Tube decimeter has been evaluated as a sensor for measuring the concentration of oil in the liquid line of a refrigeration system. Calibration and performance tests were conducted under simulated liquid-line conditions for R-407C/POE oil and R-410A/POE oil mixtures in oil concentration from 0 to 15 weight percent. Test temperatures ranged from 20 to 5$0^{\circ}C$. As a result of test, oil concentration correlations are presented in terms of specific gravity at each constant temperature. These equations enable to predict the oil concentration without any extraction of the mixture, and can be applied for R-407C/POE oil and R-410A/POE oil mixtures.

  • PDF

A Hybrid Malfunction Diagnostic System using Rules and Cases (규칙 및 사례기반의 하이브리드 고장진단 시스템)

  • 이재식;김영길
    • Journal of Intelligence and Information Systems
    • /
    • v.4 no.1
    • /
    • pp.115-131
    • /
    • 1998
  • Customer service process is one of the most important processes in today's competitive business environment. Among the various activities of customer service process, equipment malfunction diagnosis activity should be performed fast and accurately. When a customer calls the service center and reports the observed symptoms, he/she describes them in layman's terms. Therefore, the customer-reported symptoms have not been considered helpful information for service representatives. However, in order to perform diagnosis activity fast and accurately, we need to make use of the customer-reported symptoms actively. In this research, we developed three systems called R-EMD (Rule-based Equipment Malfunction Diagnostic system), C-EMD (Case-based Equipment Malfunction Diagnostic system) and R&C-EMD (Rule & Case-based Equipment Malfunction Diagnostic system), each of which diagnoses equipment malfunctions using the customer-reported symptoms. R&C-EMD is a hybrid system that utilizes both rule-based and case-based technologies. The diagnosis rules used in R&C-EMD and R-EMD were not acquired from service manuals or interviews with service representatives. Rater, we extracted them directly from the past diagnosis cases based on symptoms' frequencies. By this way, we were able to overcome the knowledge acquisition bottleneck. Using the real 100 malfunction diagnosis cases, we evaluated the performances of R&C-EMC, R-EMD and C-EMD in terms of speed and accuracy. In diagnosis time, R&C-EMD took longer than R-EMD and shorter than C-EMD. However, R&C-EMC was the best in accuracy.

  • PDF

Effects of SiC Cluster on Mechanical Properties of the 2024A1/$SiC_p$ Composites (2024A1/$SiC_p$복합재료의 기계적특성에 미치는 SiC클러스터의 영향)

  • 김홍물;천병선
    • Journal of Powder Materials
    • /
    • v.8 no.2
    • /
    • pp.124-130
    • /
    • 2001
  • A centrifugally atomized 2024A1/SiC/sub p/ composites were extruded to study effect of clusters on mechanical properties, and a model was proposed that the strength of MMCs would be estimated from the load transfer model approach that taken into consideration of the clusters. This model has been successfully utilized to predict the strength and fracture toughness of MMCs. The experimental and calculated results show coincidence and that the fracture toughness decreases with increasing the volume fraction of particles. On the basis of experimental observations, we suggest that the strength and fracture toughness of particle reinforced MMCs may be calculated from; σ/sub y/=σ/sub m/V/sub m/+σ/sub r/(V/sub r/-V/sub c)-σ/sub r/V/sub c/, K/sub IQ/=σ/sub Y/((3πt)((r/sub r//V/sub r/)(r/sub c//V/sub c/))/sup 1/2/)/sup 1/2/, respectively.

  • PDF

ON v-MAROT MORI RINGS AND C-RINGS

  • Geroldinger, Alfred;Ramacher, Sebastian;Reinhart, Andreas
    • Journal of the Korean Mathematical Society
    • /
    • v.52 no.1
    • /
    • pp.1-21
    • /
    • 2015
  • C-domains are defined via class semigroups, and every C-domain is a Mori domain with nonzero conductor whose complete integral closure is a Krull domain with finite class group. In order to extend the concept of C-domains to rings with zero divisors, we study v-Marot rings as generalizations of ordinary Marot rings and investigate their theory of regular divisorial ideals. Based on this we establish a generalization of a result well-known for integral domains. Let R be a v-Marot Mori ring, $\hat{R}$ its complete integral closure, and suppose that the conductor f = (R : $\hat{R}$) is regular. If the residue class ring R/f and the class group C($\hat{R}$) are both finite, then R is a C-ring. Moreover, we study both v-Marot rings and C-rings under various ring extensions.

RELATING GALOIS POINTS TO WEAK GALOIS WEIERSTRASS POINTS THROUGH DOUBLE COVERINGS OF CURVES

  • Komeda, Jiryo;Takahashi, Takeshi
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.1
    • /
    • pp.69-86
    • /
    • 2017
  • The point $P{\in}{\mathbb{P}}^2$ is referred to as a Galois point for a nonsingular plane algebraic curve C if the projection ${\pi}_P:C{\rightarrow}{\mathbb{P}}^1$ from P is a Galois covering. In contrast, the point $P^{\prime}{\in}C^{\prime}$ is referred to as a weak Galois Weierstrass point of a nonsingular algebraic curve C' if P' is a Weierstrass point of C' and a total ramification point of some Galois covering $f:C^{\prime}{\rightarrow}{\mathbb{P}}^1$. In this paper, we discuss the following phenomena. For a nonsingular plane curve C with a Galois point P and a double covering ${\varphi}:C{\rightarrow}C^{\prime}$, if there exists a common ramification point of ${\pi}_P$ and ${\varphi}$, then there exists a weak Galois Weierstrass point $P^{\prime}{\in}C^{\prime}$ with its Weierstrass semigroup such that H(P') = or , which is a semigroup generated by two positive integers r and 2r + 1 or 2r - 1, such that P' is a branch point of ${\varphi}$. Conversely, for a weak Galois Weierstrass point $P^{\prime}{\in}C^{\prime}$ with H(P') = or , there exists a nonsingular plane curve C with a Galois point P and a double covering ${\varphi}:C{\rightarrow}C^{\prime}$ such that P' is a branch point of ${\varphi}$.

Low Resistivity Ohmic Ni/Si/Ni Contacts to N-Type 4H-SiC (낮은 접촉저항을 갖는 Ni/Si/Ni n형 4H-SiC의 오옴성 접합)

  • Kim C. K.;Yang S. J.;Cho N. I.;Yoo H. J.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.495-499
    • /
    • 2004
  • Characteristics of ohmic Ni/Si/Ni contacts to n-type 4H-SiC are investigated systematically. The ohmic contacts were formed by annealing Ni/Si/Ni sputtered sequentially The annealings were performed at 950℃ using RTP in vacuum ambient and N₂ ambient, respectively. The specific contact resistivity(p/sub c/), sheet resistance(R/sub s/), contact resistance (R/sub c/) transfer length(L/sub T/) were calculated from resistance(R/sub T/) versus contact spacing(d) measurements obtained from TLM(transmission line method) structure. While the resulting measurement values of sample annealed at vacuum ambient were p/sub c/ = 3.8×10/sup -5/Ω㎠, R/sub c/ = 4.9 Ω and R/sub T/ = 9.8 Ω, those of sample annealed at N₂ ambient were p/sub c/ = 2.29×10/sup -4/Ω㎠, R/sub c/ = 12.9 Ω and R/sub T/ = 25.8 Ω. The physical properties of contacts were examined using XRD 3nd AES. The results showed that nickel silicide was formed on SiC and Ni was migrated into SiC. This result indicates that Ni/Si/Ni ohmic contact would be useful in high performance electronic devices.

Deposition of 3C-SiC Films by Plasma-enhanced Chemical Vapor Deposition (I): Deposition Behaviors of SiC with Deposition Parameters (PECVD법에 의한 3C-SiC막 증착(I): 증착변수에 따른 SiC 증착거동)

  • 김광호;서지윤;윤석영
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.6
    • /
    • pp.531-536
    • /
    • 2001
  • SiCl$_4$/CH$_4$/H$_2$계를 사용한 플라즈마 화학증착법(PECVD)으로 실리콘(100) 기판 위에 3C-SiC막을 117$0^{\circ}C$~1335$^{\circ}C$의 온도범위에서 증착하였다. 증착온도, 유입가스비, R$_{x}$ [=CH$_4$/(CH$_4$+H$_2$)], 그리고 r.f. power를 변화시켜 증착막의 결정성에 대해 검토하였다. Thermal CVD에 비해 PECVD법은 박막의 증착속도를 향상시켰다. 증착된 3C-SiC은 (111) 면으로 최대의 우선배향성을 지님을 알 수 있었다. 실리콘 기판 위의 3C-SiC막의 결정성은 R$_{x}$값에 의존하였으며, R$_{x}$가 감소할수록 결정성이 더욱 향상되었다. Free Si가 3C-SiC막과 함께 증착되었으나, 증착온도와 r.f power가 증가함에 따라 free Si의 함량은 감소하였다. 증착온도 127$0^{\circ}C$, 유입가스비 R$_{x}$=0.04, r.f. power가 60W에서 비교적 결정성을 가진 3C-SiC막을 얻을 수 있었다.

  • PDF