• Title/Summary/Keyword: C/R

Search Result 18,400, Processing Time 0.055 seconds

Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-407C (혼합냉매 R-407C의 증발 열전달과 압력강하)

  • Roh, Geon-Sang;Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.542-549
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a horizontal copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300\;kg/m^2s$ and the saturation temperature of evaporator were $5^{\circ}C$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the increase of mass flux and vapor quality. The evaporation heat transfer coefficients of R-22 is about $5.68{\times}46.6%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is similar to that of R-407C. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of R-22 and R-407C. therefore, it is necessary to develope reliable and accurate predictions determining the evaporation heat transfer coefficient of R-22 and R-407C in a horizontal tube.

Comparison of Condenser Characteristics Using R407C and R22 on the Same Inlet Temperature Condition (동일한 유입온도조건에서 R407C와 R22 적용 응축기의 특성비교)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.595-603
    • /
    • 2003
  • R407C is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the condensation heat transfer and pressure drop for R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$ , relative humidity of 50% and air velocity varying from 0.8 to 1.6 m/s. Experiments show that air velocity increased by 25% is needed for R407C than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 28.8% for R407C as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires higher electric-power consumption with R407C than that with R22.

PHOTOMOVEMENTS IN MICROORGANISMS

  • Lenci F.;Angelini N.;Checcucci G.;Ghetti F.;Gioffre D.;Sgarbossa A.
    • Proceedings of the Korean Society of Potoscience Conference
    • /
    • spring
    • /
    • pp.20-20
    • /
    • 1996
  • PDF

A Study on the Prediction of the Permanent Wilting Point in Woody Plant by Cambial Electrical Resistance (목본식물의 형성층 전기저항에 의한 영구위조점 예측에 관한 연구)

  • 김민수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.4
    • /
    • pp.75-80
    • /
    • 1995
  • It is important to estimate the possibility of recovery in physiologically damaged woody plant. It is suggested that C.E.R(cambial electrical resistance) might be a useful method to predict the permanent wilting point. D/A and A/D converter can be used to measure the C.E.R and it took only 10-20 msec for a measurement and the values were stable during this study. A computer could be used for the continual measurement of C.E.R. There were very big daily changes of C.E.R. was changed according to the changes of indoor temperature, but the phase was slightly different. It is reasoned that daily changes in C.E.R. is induced by the changes of water potential and cambial thickness. It was difficult to detect the changes of C.E.R. caused by changes in soil moisture under high soil water potential. Under low soil water potential, the changes in soil moisture under high soil water potential. Under low soil water potential, the changes of C.E.R. can be detected. After wilting, C.E.R. is increased very rapidly. When C.E.R. is not decreased by watering, it will be permanent wilting point. But it takes several days to confirm the permanent wilting point. To predict the possibility of recovery from wilting, the values of C.E.R. have no meaning. But the changes of C.E.R. are significant. Therefore we can predict the permant wilting point in woody plant by monitoring the change of C.E.R. by the computer.

  • PDF

A Study on the P.T.C.R-N.T.C.R. Ceramic Resister (P.T.C.R.-N.T.C.R. 자기를 이용한 저항체에 관한 연구)

  • 안영필;이병하;김일기
    • Journal of the Korean Ceramic Society
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 1981
  • The thermostable resistor was made by using P.T.C.R-N.T.C.R. ceramics. In this study $BaTiO_3$ type P.T.C.R. ceramics and $SnO_2-Sb_2O_3$ type N.T.C.R. ceramics were cocrystallized in one body and electrical resistance was stable under the temperature variation between $25^{\circ}C$-40$0^{\circ}C$. The ceramics showed the most stable electrical resistance for the mal variation when the composition was 0.6P.T.C.R. $BaTiO_3$,$ 0.4SnO_2$ and 0.01 $Sb_2O_3$.

  • PDF

A Novel Complement Fixation Pathway Initiated by SIGN-R1 Interacting with C1q in Innate Immunity

  • Kang, Young-Sun
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2008.05a
    • /
    • pp.23-25
    • /
    • 2008
  • Serum complement proteins comprise an important system that is responsible for several innate and adaptive immune defence mechanisms. There were three well described pathways known to lead to the generation of a C3 convertase, which catalyses the proteolysis of complement component C3, and leads to the formation of C3 opsonins (C3b, iC3b and C3d) that fix to bacteria. A pivotal step in the complement pathway is the assembly of a C3 convertase, which digests the C3 complement component to form microbial-binding C3 fragments recognized by leukocytes. The spleen clears microorganisms from the blood. Individuals lacking this organ are more susceptible to Streptococcus pneumoniae. Innate resistance to S. pneumoniae has previously been shown to involve complement components C3 and C4, however this resistance has only a partial requirement for mediators of these three pathways, such as immunoglobulin, factor B and mannose-binding lectin. Therefore it was likely that spleen and complement system provide resistance against blood-borne S. pneumoniae infection through unknown mechanism. To better understand the mechanisms involved, we studied Specific intracellular adhesion molecule-grabbing nonintegrin (SIGN)-R1. SIGN-R1, is a C-type lectin that is expressed at high levels by spleen marginal-zone macrophages and lymph-node macrophages. SIGN-R1 has previously been shown to be the main receptor for bacterial dextrans, as well as for the capsular pneumococcal polysaccharide (CPS) of S. pneumoniae. We examined the specific role of this receptor in the activation of complement. Using a monoclonal antibody that selectively downregulates SIGN-R1 expression in vivo, we show that in response to S. pneumoniae or CPS, SIGN-R1 mediates the immediate proteolysis of C3 and fixation of C3 opsonins to S. pneumoniae or to marginal-zone macrophages that had taken up CPS. These data indicate that SIGN-R1 is largely responsible for the rapid C3 convertase formation induced by S. pneumoniae in the spleen of mice. Also, we found that SIGN-R1 directly binds C1q and that C3 fixation by SIGN-R1 requires C1q and C4 but not factor B or immunoglobulin. Traditionally C3 convertase can be formed by the classical C1q- and immunoglobulin-dependent pathway, the alternative factor-B-dependent pathway and the soluble mannose-binding lectin pathway. Furthermore Conditional SIGN-R1 knockout mice developed deficits in C3 catabolism when given S. pneumoniae or its capsular polysaccharide intravenously. There were marked reductions in proteolysis of serum C3, deposition of C3 on organisms within SIGN-$R1^+$ spleen macrophages, and formation of C3 ligands. The transmembrane lectin SIGN-R1 therefore contributes to innate resistance by an unusual C3 activation pathway. We propose that in the SIGN-R1 mediated complement activation pathway, after binding to polysaccharide, SIGN-R1 captures C1q. SIGN-R1 can then, in association with several other complement proteins including C4, lead to the formation of a C3 convertase and fixation of C3. Therefore, this new pathway for C3 fixation by SIGN-R1, which is unusual as it is a classical C1q-dependent pathway that does not require immuno globulin, contributes to innate immune resistance to certain encapsulated microorganisms.

  • PDF

Separation of Linear and Elliptic Particle Motions Using Multi-Component Complex Trace Analysis (다성분 복소트레이스 분석법에 기초한 선형 및 타원형 입자운동 분리)

  • Kim, Ki-Young;Lee, So-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.246-254
    • /
    • 2009
  • We developed a novel polarization filter to separate linearly polarized waves from elliptically polarized waves in an infinite homogeneous medium and at the free surface using methods of multicomponent complex trace analysis. Sensitivity to filter parameters were examined using synthetic data simulating particle motions in a homogeneous medium. For known amplitude ratios of horizontal-to-vertical components of P and Rayleigh waves $C_L$ and $C_R$, respectively, the polarization filter precisely removes Rayleigh waves. Errors in the vertical and horizontal components of the filtered results increase with the ratio $C_R$/$C_L$ and the product $C_R$.$C_L$, respectively. The vertical component errors also increase rapidly as the ratios of applied-to-modeled values of $C_L$ and $C_R$ ($C_L'$/$C_L$ and $C_R'$/$C_R$) decrease, and are sensitive to $C_R'$/$C_R$ and $C_L'$/$C_L$ for small and large incidence angles, respectively. Errors of the filter are exactly the same for shear waves when the incidence angle is the supplementary of P-wave incidence angle.

Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser (응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험)

  • 김창덕;박일환;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.

Properties of a Surface Curvature in Toric Lens (토릭렌즈의 표면 곡률 특성 연구)

  • Park, Sang-An;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2001
  • We obtained the sum of two curvature ($C_x+C_y$) in toric lens which two toroidal surface is the right angle each other. $$C_x+C_y=\frac{x^2+y^2}{2r_1}+\frac{x^2}{2}(\frac{1}{r_2}-\frac{1}{r_1})$$ and the sum of two curvature ($C_a+C_b$) in toric lens about the cross angle. $$(C_a+C_b)=\frac{x^2cos^2{\alpha}_1}{2r_1}+\frac{x^2cos^2{\alpha}_2}{2r_2}+\frac{y^2sin^2{\alpha}_1}{2r_1}+\frac{y^2sin^2{\alpha}_2}{2r_2}$$ and claculated the parameter S, C, ${\theta}$ of a combination power in toric lens of the cross angle including surface curvature ($C_x$, $C_y$) values. $$S=(n-1)\[\frac{C_x}{x^2}+\frac{C_y}{y^2}\]-\frac{C}{2},\;C=-\frac{2(n-1)}{sin2{\theta}}\[\frac{C_x}{x^2}+\frac{C_y}{y^2}\]$$ $${\theta}=\frac{1}{2}tan^{-1}\[-\frac{{C_xy^2sin2{\theta}_1}+{C_yx^2sin2{\theta}_2}}{{C_xy^2cos2{\theta}_1}+{C_yx^2cos2{\theta}_2}}\]$$.

  • PDF