• 제목/요약/키워드: Bypass pipe

검색결과 21건 처리시간 0.029초

고무보 저층수 배출관의 유사 배제 성능 실험 연구 (Experimental Study for Flushing of Sediment Bypass Pipe underneath Rubber Weir)

  • 정석일;이승오
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.133-140
    • /
    • 2016
  • Most small weir installed in Korea is concrete solidated weir. Fixed weir causes stagnant flow, which leads to deposit sediment just upstream of weir. As time goes on, it would induce reduction of water storage capacity and invoke the serious water quality issues. Therefore, there has been a growing interest in movable weir. Especially, the flexible rubber weir is easy to install and possible to operate in extreme environments. However, even though this type can be flatable, it is also not free from sediment deposition problem. Thus, to enhance the ability of releasing deposition the bypass pipe was constructed underneath it. In this study the performance of its ability was examined with hydraulic model test. This bypass pipe was designed with 3 different dimensions to connect between each bottom of upstream and downstream of a weir, such as Type A, B, and C. The efficiency of drainage of deposition upstream was studied under two water of upstream and sediment heights. In addition, the ability of sediment emission through the bypass pipe after the pipe was blocked by debris like soil, vegetation et al. was examined by video monitoring. From this study, it was suggested a dimensionless equation which show the relationship of variable parameters and amount of emission sediment through bypass pipe. And it was found that the most significant factors on efficiency of releasing were elbow angle and discharge, and the ability of emission when the pipe was blocked was most highly influenced in tilting length.

저층수 배출관에 유입된 사석의 배제 한계조건 (Threshold Condition for Exclusion of Riprap into Bypass Pipe)

  • 정석일;이승오
    • 한국방재안전학회논문집
    • /
    • 제12권1호
    • /
    • pp.57-66
    • /
    • 2019
  • 국내 중소하천에 설치된 콘트리트 보에서 발생하는 많은 문제 중에서 상류로부터 유입되는 유사가 보 직상류에 퇴적되는 문제가 심각하다. 이로 인해 하류에 유사공급이 원활치 못하게 되며, 퇴적된 유사가 오염물과 흡착될 경우, 하상 오염뿐만 아니라 하천 생태계에 치명적인 피해를 유발할 수 있다. 보 직상류의 유사 퇴적문제를 해결하는 방안 중 하상에 배사관을 매설하여 퇴적되는 유사를 하류로 배출하고 있다. 그러나 배사관에 적정크기 이상의 사석 등이 유입될 경우, 배사효율은 현격하게 낮아지므로, 이에 대한 가이드라인 내지는 한계조건 제시가 필요하다. 본 연구에서는 상하류 수위차, 사석의 직경 등을 주요변수로 선정한 후, 3차원 수치모의 결과를 활용하여 사석 배제 능력에 대한 한계 조건을 도출하였다. 상류흐름은 정류된 상태로 가정하였고, 배사관을 포함하여 상 하류간 검사체적에서 에너지 개념을 적용하여 분석을 수행하였다. 그 결과 수위차와 사석지름의 비로 나타낸 무차원 변수가 약 1.2인 경우, 배사관 내 사석의 배출유뮤를 명확히 결정할 수 있었다. 본 연구결과는 향후 점성이 높은 유사나 흡착성 유사 등의 특성을 고려한다면 배사관이 있는 고정보의 운영관리방안에 활용될 수 있을 것이라 기대한다.

소결금속 윅과 메탄올을 사용하며 바이패스라인이 부착된 루프히트파이프의 작동 특성 (Operating Characteristics of a Sintered-Metal Wick/Methanol Loop Heat Pipe Having a Bypass Line)

  • 부준홍;정의국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2130-2135
    • /
    • 2007
  • Operating characteristics of a loop heat pipe (LHP) having a bypass line was investigated experimentally. The LHP had a sintered metal wick as a capillary structure and methanol as a working fluid. The sintered metal wick was made of stainless steel of which the average pore size was 5 ${\mu}m$and porosity of 47%. A bypass line of a small diameter was attached between the vapor escape passage and the liquid reservoir. The dimension of the flat evaporator was $50(L){\times}40(W){\times}30(H)$ mm and that of the condenser was $50(L){\times}40(W){\times}11(H)$ mm. Wall and pipe material of the LHP was stainless steel and heating area was 35(W) mm${\times}$35(L) mm. The inner diameters of vapor and liquid transport lines were 4.0 mm and 2.0 mm, and the lengths of the two lines were both 0.5 m. The LHP was tested for three different tilt angles of horizontal, favorite tilt, and adverse tilt. The thermal load range was up to 290 W at the condenser above evaporation position. Furthermore, the effect of a bypass line on the start-up transient as well as steady-state operation was presented and discussed.

  • PDF

울진 원자력 5&6호기 Motor Operated Valve의 Equalizing Bypass Pipe Line에 대한 피로수명예측

  • 이진구;황인현;이억섭
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2001년도 공동학술대회
    • /
    • pp.219-224
    • /
    • 2001
  • 본 연구는 울진 원자력발전소 5&6호기 Class 1680, Parallel Gate 16-inch, Motor Operated Valve (Valve ID No. SI-653 and 654)에 부착되는 Equalizing Bypass Pipe Line (EBPL)이 밸브 시스템에 발생시키는 진동하중에 의한 영향을 동적 피로안정성 관점에서 규명하기 위하여 수행된 것이다. Equalizing Bypass Line Part의 최종 설계된 형상을 Fig. 1에 나타내었다. 본 해석을 위하여 운용 중 발생되는 부착부의 잔류진동 레벨이 3축 방향 가속도로 측정되었다. 본 연구에서는 해당 시변 가속도 데이터를 바탕으로 정확한 시간-응력 이력을 얻기 위하여 시간영역에서 천이 진동해석 (Transient Vibration Analysis)을 수행하였으며, 이를 실제적인 피로해석에 활용하였다. 시간영역에서의 천이 진동해석 및 피로해석을 위해 상용유한요소 해석프로그램인 ANSYS (Version 5.6)를 활용하였다.(중략)

  • PDF

Thermal-hydraulic and load following performance analysis of a heat pipe cooled reactor

  • Guanghui Jiao;Genglei Xia;Jianjun Wang;Minjun Peng
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1698-1711
    • /
    • 2024
  • Heat pipe cooled reactors have gained attention as a potential solution for nuclear power generation in space and deep sea applications because of their simple design, scalability, safety and reliability. However, under complex operating conditions, a control strategy for variable load operation is necessary. This paper presents a two-dimensional transient characteristics analysis program for a heat pipe cooled reactor and proposes a variable load control strategy using the recuperator bypass (CSURB). The program was verified against previous studies, and steady-state and step-load operating conditions were calculated. For normal operating condition, the predicted temperature distribution with constant heat pipe temperature boundary conditions agrees well with the literature, with a maximum temperature difference of 0.4 K. With the implementation of the control strategy using the recuperator bypass (CSURB) proposed in this paper, it becomes feasible to achieve variable load operation and return the system to a steady state solely through the self-regulation of the reactor, without the need to operate the control drum. The average temperature difference of the fuel does not exceed 1 % at the four power levels of 70 %,80 %, 90 % and 100 % Full power. The output power of the turbine can match the load change process, and the temperature difference between the inlet and outlet of the turbine increases as the power decreases.

유전자 알고리듬을 이용한 선박용 파이프 경로 최적화 (Ship Pipe Layout Optimization using Genetic Algorithm)

  • 박철우;천호정
    • 한국정밀공학회지
    • /
    • 제29권4호
    • /
    • pp.469-478
    • /
    • 2012
  • This study aims to discover the optimal pipe layout for a ship, which generally needs a lot of time, efforts and experiences. Genetic algorithm was utilized to search for the optimum. Here the optimum stands for the minimum pipe length between two given points. Genetic algorithm is applied to planar pipe layout problems to confirm plausible and efficiency. Sub-programs are written to find optimal layout for the problems. Obstacles are laid in between the starting point and the terminal point. Pipe is supposed to bypass those obstacles. Optimal layout between the specified two points can be found using the genetic algorithm. Each route was searched for three case models in two-dimensional plane. In consequence of this, it discovered the optimum route with the minimized distance in three case models. Through this study, it is possible to apply optimization of ship pipe route to an actual ship using genetic algorithm.

저층수 배사관 내 유입된 사석 배출능력에 대한 연구 (A Experimental Study on Exclusion Ability of Riprap into Bypass Pipe)

  • 정석일;이승오
    • 대한토목학회논문집
    • /
    • 제37권1호
    • /
    • pp.239-246
    • /
    • 2017
  • 국내 중소하천의 횡단구조물인 보 또는 낙차공은 대부분 고정식 콘크리트 구조물이며, 저층수의 배제가 쉽지 않다. 횡단구조물로 인해 유사가 퇴적되며, 유사에 흡착한 오염물들이 그대로 하천의 바닥을 오염시키고 있다. 이에 저층수 및 퇴적유사에 대한 관심이 증가하고 있는 실정이며, 이러한 대안의 하나로 횡단구조물 상류와 하류를 하상 아래로 연결시키는 구조물로써, 보 상류 저층의 물 및 유사 배제를 목적으로 저층수배출관을 설치하는 방안이 있다. 그러나 사석이 유입되고, 배제 되지 않을 경우 효율성이 크게 저하될 가능성이 있다. 이에 본 연구에서는 저층수 배출관 내 사석을 배제할 수 있는 능력에 대한 연구를 수행하였다. 사석과 거동이 유사한 유사(sediment)의 한계조건(critical condition) 중 한계전단력(critical shear stress) 유도과정과 달랑베르의 원리(d'Alembert principle)를 응용하여 이동 중인 사석이 배제될 수 있는 조건(${\tau}_c{^*}$)을 유도하였다. 그러나 저층수 배출관 내 유입된 사석은 정지상태가 아닌 이동 중이므로, Lagrangian 기법을 활용하여 수리실험에서 도출된 유속으로 상대속도(relative velocity)를 제시하였다. 수리실험은 축척효과(scale effect)를 최소화하기 위해 폭이 5.0 m이고, 높이가 1.0 m인 광폭 개수로를 제작하였으며, 사용된 사석은 가공된 완전 구형을 사용하였다. 실험 결과 유속과 구형 입자 속도와의 비가 0.5~0.7 사이로 나타났으며, 이러한 결과를 유도된 식에 적용하여, 최종적으로 사석이 배제되는 조건을 도출하게 되었다. 구간은 입자레이놀즈수($Re_p$)와 무차원 한계 전단력(${\tau}_c{^*}$)에 따라 크게 3가지로 구분되었다. 배제 구간(exclusion section), 확률적 배제 구간(probabilistic exclusion section), 비배제 구간(no exclusion section)이다. 본 연구결과는 횡단구조물의 저층수 배출관 설계시 유용한 기초 정보를 제공할 수 있을 것이다.

75톤급 로켓엔진용 연료펌프의 수력성능시험 (Hydraulic Tests of Fuel Pump for 75-ton class Liquid Rocket Engines)

  • 김대진;홍순삼;최창호;노준구;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.78-81
    • /
    • 2009
  • 연료펌프에 대한 수력성능시험을 상온의 물을 매질로 하여 실시하였다. 시험된 연료펌프는 개방형 가스발생기 방식의 75톤급 액체로켓엔진에 적용할 목적으로 개발 중에 있다. 시험 결과, 연료펌프는 설계요구조건을 만족하였으며, 설계 유량에서의 양정과 효율은 수치해석에서 추정된 값보다 높았다. 또한 후방 베어링의 출구 압력이 예상보다 높았는데 이는 바이패스 배관의 입구가 좁기 때문이었다. 그리고 바이패스 곡관부의 차압 측정으로 누설 유량을 유추할 수 있었다.

  • PDF

수격현상에 대한 수치적 고찰 (A Computational Analysis of Water-Hammer)

  • 전광민
    • 대한설비공학회지:설비저널
    • /
    • 제11권1호
    • /
    • pp.1-10
    • /
    • 1982
  • The water-hammer phenomena caused by pump power failure are analysed by digital computer. Asan cool ins water pipe system has been chosen as a model. It is Shown that after power failure the pressure at the pump outlet drops sharply, and to prevent reverse flow, either butterfly valve or check valve can be used. After the valve closure, pressure oscillates behind the valve. To weaken the pressure wave, it is recommended to install a servo-operated valve in a bypass Line around the pamp and the check valve.

  • PDF

3차원 수치모의를 통한 저층수 배사관 내 유입된 사석의 배제 한계조건에 대한 연구 (A Study on the Exclusion Threshold Condition of the Riprap in the Bypass Pipe by 3D Numerical Simulation)

  • 박선빈;정석일;이승오
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.132-132
    • /
    • 2017
  • 큰 하상계수를 가지는 국내 중소하천의 특성상 농업용수 등의 수자원 이용을 위해 국내에는 약 10,000개 정도의 하천 횡단구조물이 설치되어 있다. 그러나 느려진 유속으로 인하여 횡단구조물 상류에 유사가 퇴적될 확률이 높아지며, 이러한 유사는 부착된 오염물에 의한 수질 및 하상오염, 좁아진 유수단면적에 의한 통수능 저하로 발생하는 홍수위 증가 등 많은 위험성을 내포하고 있다. 이에 대한 해결책 중의 하나로 저층수 배사관(bypass pipe)을 활용하여 쌓여진 유사를 하류로 흘려보내는 방법이 있다. 저층수 배사관은 횡단구조물 상류와 하류의 하상을 연결하는 관으로써 상류와 하류의 수두차에 의해 흐름 특성이 결정된다. 하지만 배사관 내 사석이 유입되어 배제되지 않는 경우 배사관의 효율이 현저하게 저하될 가능성이 있다. 본 연구에서는 FLOW-3D를 이용하여 배사관내 사석이 유입되었을 때, 어떠한 조건에서 배제되고 배제되지 않는지를 명확히 하고자 한다. 하상이 평탄한 수로$(13.0(L){\times}5.0(B){\times}1.0(H)m)$를 재현하였으며, 배출관의 직경은 10cm로 결정하였다. 사석의 종류는 4가지(3cm, 5cm, 7cm, 9cm)로써 이를 고려하여 격자크기를 0.5cm로 결정하였다. 이는 사석의 구형형상이 충분히 잘 재현될 수 있는 격자크기이다. 모의 수행은 하류의 수위를 변화시켜가며 수행하였다. 저층수 배사관 내 유동 특성이 상류와 하류의 수두차에 의해 결정되기 때문에, 모의의 효율성을 위해 상류의 수위는 일정한 값으로 진행하였다. 모의 결과 수위차가 클수록 배제가 잘되는 경향을 보였다. 입자의 크기와 상하류 수위차를 무차원화 한 변수를 결정하였다. 분석결과 이 변수가 일정 값을 넘어서는 경우 배제가 되며, 반대로 이 값을 넘어서지 못한 경우 배제가 되지 않음을 확인하였다. 향후 다양한 관의 형상에 대해서도 배사관 내 한계조건을 도출하여, 저층수 배사관의 설계 및 시공에 도움이 되고자 한다.

  • PDF