• 제목/요약/키워드: Bypass control

검색결과 257건 처리시간 0.028초

고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation)

  • 안재환;주영주;윤원재;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

발전소 시뮬레이터를 위한 고압 터빈 바이패스 압력 제어 모델 개발 (Development of a High Pressure Turbine Bypass System Pressure Control Model for Power Plant Simulator)

  • 변승현;이주현;임익헌
    • 한국시뮬레이션학회논문지
    • /
    • 제20권4호
    • /
    • pp.49-58
    • /
    • 2011
  • 국산 개발 분산 제어시스템의 발전 설비에의 적용을 위해서는 시뮬레이터를 이용한 제어 시스템의 기능 및 신뢰성 등의 검증이 선행되어야만 한다. 본 논문에서는 제어 시스템 검증용 시뮬레이터를 개발하는데 있어서, 제어 모델 중 발전소 기동 초기에 보일러 압력을 조절하고, 정상 운전 중 보일러의 과대 압력 상승을 방지하기 위해 보일러에서 발생한 증기를 복수기로 방출하는 터빈 바이패스 계통의 제어 모델을 개발하였다. 제어 모델 개발을 위해, 통합 시뮬레이션 개발 환경에서 활용가능한 제어 로직 구현 툴을 개발하였다. 또한 개발한 툴의 기능은 개별 기능 블럭의 설계 사양에 기반한 시뮬레이션에 의해 검증을 하였으며, 개발한 툴을 이용하여 고압 터빈 바이패스 계통의 압력 제어 로직을 구현하였다. 500 MW급 표준 석탄화력 발전소 공정 모델과 보일러 제어 모델, 터빈 제어 모델 등 타 계통의 제어 모델과의 연계를 통한 통합 시뮬레이션을 통해 개발한 제어 모델의 효용성을 확인하였다.

산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교 (Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler)

  • 백승문;문춘근;김은필;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.429-435
    • /
    • 2011
  • 본 연구는 현재 시판되어 산업현장에서 사용 중인 산업용냉각기의 대표적인 타입인 온오프 제어기가 채용된 냉각기와 토출가스 바이패스 제어기가 채용된 냉각기의 온도 제어 시스템의 운전특성 및 제어 특성을 비교분석하였다. 온오프 제어 냉각기보다 토출가스 바이패스 제어 냉각기는 최소 8%, 최대 20% COP가 높게 나타났다. 이러한 결과들은 산업 현장에서 좀 더 상황에 맞는 제품의선정을 할 수 있는 기초 자료로서 활용될 수 있으리라 생각된다.

회전교차로 우회전 별도차로 설치 효과 검토 (Effectiveness Analysis on the Installation of Right-Turn Bypass Lane in Roundabout)

  • 임진강;김경환;박병호
    • 한국도로학회논문집
    • /
    • 제12권4호
    • /
    • pp.29-37
    • /
    • 2010
  • 이 논문은 회전교차로 우회전 별도차로를 다루고 있다. 본 연구의 목적은 회전교차로 기하구조의 설계요소 중 우회전 별도차로의 설치에 따른 효과를 분석하는데 있다. 이를 위해 VISSIM을 이용하여 우회전 별도차로의 설치 전 후를 비교 분석하였다. 또한 우회전 별도차로 설치 방식인 양보에 의한 통제 형태와 합류에 의한 통제 형태의 운영효과를 비교 분석하였다. 주요 결과는 다음과 같다. 첫째, 우회전 별도차로 설치 후에는 우회전 교통량비의 증가에 따라 지체가 점차적으로 감소하여 최대 평균 약 28% 감소하는 것으로 나타났다. 둘째, 양보에 의한 통제 형태와 합류에 의한 통제 형태 모두 우회전 교통량이 증가할수록 지체가 감소하였다. 또한 합류에 의한 통제 형태가 양보에 의한 통제 형태보다 최대 평균 약 18% 지체감소 효율이 있는 것으로 나타났다.

A Study on High Precision Temperature Control of an Oil Cooler for Machine Tools Using Hot-gas Bypass Method

  • Jung, Young-Mi;Byun, Jong-Yeong;Yoon, Jung-In;Jeong, Seok-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권7호
    • /
    • pp.1003-1011
    • /
    • 2009
  • This study aims at precise control of oil outlet temperature in the oil cooler system of machine tools for enhancement of working speed and processing accuracy. PID control logic is adopted to obtain desired oil outlet temperature of the oil cooler system with hot-gas bypass method. We showed that the gains of PID controller could be easily determined by using gain tuning methods to get the gain of PID controller without any mathematical model. We also investigated various gain tuning methods to design the gains of PID and compared each control performance for selecting the optimal tuning method on the hot gas bypass method through experiments. Moreover, we confirmed excellent control performance with proposed PI controller gain even though disturbances were abruptly added to the experimental system.

아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법 (The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control)

  • 김석희;최병민;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.

증기터빈 Bypass Valve 의 유동장 해석 (Analysis of flow Field in a steam turbine LP/HP Bypass control Valve)

  • 최지용;김광용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.437-440
    • /
    • 2005
  • In the present work, characteristics of the flow in CAGE of a steam turbine LP/HP Bypass control valve for thermal power plant are investigated. The flow field is analyzed numerically by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure.

  • PDF

토출가스 바이패스제어에 의한 산업용 냉각기의 온도제어 (Temperature Control of Oil Cooler with Hot-gas Bypass)

  • 변종영;주우진;최준혁;문춘근;윤정인;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.961-966
    • /
    • 2009
  • This paper presents precise temperature control of oil outlet in an oil cooler with hot-gas bypass control as an industrial refrigerator. The control system was designed for obtaining precise temperature control performance even though abrupt disturbances based on flow rate control of hot-gas bypass. PID controller was adopted in feedback control system. We showed that the gain of PID could be easily determined by using gain-tuning methods without any numerical model. Through some experiments, excellent control performances such as overshoot within 1.7%, steady state temperature error within ${\pm}0.1^{\circ}C$ were established by a simple PI controller. We expect that the system can control the target temperature within error of $0.33^{\circ}C$ under abrupt disturbances.

  • PDF

제어방식에 따른 산업용 수냉각기의 운전 특성 비교 (A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.