• Title/Summary/Keyword: Bypass Line

Search Result 69, Processing Time 0.031 seconds

Hydraulic Tests of Fuel Pump for 75-ton class Liquid Rocket Engines (75톤급 로켓엔진용 연료펌프의 수력성능시험)

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Noh, Jun-Gu;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.78-81
    • /
    • 2009
  • A series of hydraulic tests of a fuel pump are performed using water at a room temperature. The pump is under development for 75-ton class liquid rocket engines of the open-loop gas generator type. According to the test results, the fuel pump satisfies its design requirement and its head and efficiency at the design flowrate are higher than the expected value by the computational analysis. Also, it is found that the pressure at the rear bearing outlet is higher than expected because the inlet of bypass pipe line is narrow. Furthermore, the flowrate of the secondary flow is estimated using the pressure difference of the elbow of the bypass pipe line.

  • PDF

Transient Overvoltages of Communication Equipment Depending on the Grounding Method of SPD (SPD 접지방식에 따른 통신기기의 과도위험전압)

  • Eom, Ju-Hong;Lee, Tae-Hyung;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.130-138
    • /
    • 2008
  • The tendency of lightning surge to propagate is a eared variously depend on the power system and subject equipment of protection. However, looking into the subject equipment with the lightning surge, the invasion route of lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the route of lightning surge incoming from between the communication lines, the communication line and the ground in addition to the power lines. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground and bypass arrester ground for safety improvement in power lines.

Ascending Aortic Dissection due to Trauma - A Case report - (외상에 의한 상행 대동맥 박리증의 치험 1례)

  • Seo, Pil-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.174-177
    • /
    • 1990
  • Aortic dissection is a challenging disease and the causes of that are well-known. Blunt chest trauma is one of the causes of aortic dissection. In such cases, nearly all cases involves the isthmic portion of descending aorta, but ascending aorta is involved in about 10. We experienced a patient who had ascending aortic dissection due to automobile accident and who showed spontaneous rupture of the aorta during operation. In this case, after installation of aortic line via left femoral artery, ascending aorta ruptured and a large amount of blood gushed out, which was suckered by cardiotomy sucker. A little delay of cardiopulmonary bypass may cause the fatal outcome in such a case because the bleeding from aorta is too much to be controlled. Fortunately, we controlled the bleeding with cardiopulmonary bypass and got the good outcome of this patient by interpositioning the vascular graft. One should suspect the possibility of aortic dissection in blunt chest trauma, and prepare all the facilities against bleeding due to rupture.

  • PDF

The Performance of Banyan Type ATM Switch using Monotonic Buffering Scheme (단조 버퍼링 방식을 이용한 Banyan형 ATM 스위치의 성능평가)

  • 김범식;우찬일;신인철
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1997.11a
    • /
    • pp.147-161
    • /
    • 1997
  • In the future, the performance of B-lSDN offering the multimedia and a various service depends on the performance of switch that is the important factor consisting of network. Bufferless banyan network consisted of MIN(multistage interconnection network) selected for- the fabric of ATM switch and has a limitation of performance because of blocking. Input buffered banyan networks with FIFO(first-in first-out) buffering scheme for the reduction of blocking and the cell bypass queueing theory for the reduction of HOL(head of line) blocking were seperately compared of the performance of switch. Specially input buffered banyan networks were applied monotonic buffering scheme that was proposed. As a result of simulation, Buffered Banyan Network with cell bypass queueing theory showed better performance than FIFO type input buffered Banyan network. Monotonic increase buffering scheme showed better performance than Monotonic decrease buffering scheme.

  • PDF

A Study on the Bypassing Device for Short-fault Current produced in Low Voltage Distributed Line (저압배전계통에서 발생한 단락전류의 Bypassing 장치에 관한 연구)

  • Youn, Y.J.;Kim, O.K.;Lee, S.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.976-978
    • /
    • 1998
  • In this paper, we designed basic concept and structure of bypassing device which promoted the activity of low voltage line-fuse, when it perceived the too small short-fault current to activate line-fuse which located at the between secondary of pole transformer and home immediately. And we study displacement of bypass contact and electromagnetic force caused by the short-fault current by the basic experiment to understand the basic characteristic of bypassing movements.

  • PDF

A study on ptimal applications of interrupt free works on distribution lines (무정전 배전공사를 위한 최적공법 연구)

  • Moon, Soo-Deog;Moon, Jeong-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1456-1458
    • /
    • 1999
  • As the system reliability of power supply is highly increased, we need distribution maintenance techniques without any power interruption. To meet such an increasing demand, a groat deal of hot line work on the high voltage overhead distribution lines has been carried out. In this regard, Hot line work techniques has being applied widely. However, hot line work techniques can not cover all kinds of work without interruption. To cope with those problems, the temporary power supply work technique such as bypass cable truck technique, temporary switch technique and mobile transformer technique was developed and applied. This paper presents the most optimal method according to distribution work contents through the comparison and analysis the characteristis and problems of the existing various work techniques. Also this paper suggested the countermeasers of the prsent problems.

  • PDF

체외순환중 발생한 대량 공기전색에 대한 상공대정맥을 통한 일시적역관류 -치험 2예-

  • 이재성
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.543-548
    • /
    • 1986
  • Massive air embolism during cardiopulmonary bypass is uncommon but serious and often lethal complication. Following this catastrophic event, the immediate institution of retrograde arterial blood perfusion via superior vena cava was made to remove air emboli from cerebral circulation. This method was performed by removing the arterial perfusion line from aortic cannula and connecting it to superior vena caval cannula. Then, retrograde perfusion at a flow rate of 2Umin via superior vena cava was carried out for 3 minutes. After air returning from the aortic cannula was identified, each line was connected to the cannulae primarily. In 2 cases who had massive air emboli due to air pumping into arterial line, the postoperative complete recovery resulted from this technique, which was used in conjunction with other therapy postoperatively.

  • PDF

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

Study on the Operating Characteristics of High Voltage Impulse Track Circuit (고전압 임펄스궤도회로의 동작특성 연구)

  • Lee, Tae-Hoon;Park, Ki-Bum;Jeon, Yong-Joo;Ryu, Young-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1279-1284
    • /
    • 2008
  • This paper presents the operating characteristic of high voltage impulse(HVI) track circuit owing to the ill-contact of impedance bond lead wire. The characteristic operations of the track include rail voltage and current. Measurements are carried out using oscilloscope with current probe and it analyzed the abnormal operation due to connector of protective wire. Finally, suitable track circuit is proposed for conventional line, and operating characteristic of HVI track circuit is affected by bypass circuit.

  • PDF

A Computational Analysis of Water-Hammer (수격현상에 대한 수치적 고찰)

  • Chun, Kwang-Min
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 1982
  • The water-hammer phenomena caused by pump power failure are analysed by digital computer. Asan cool ins water pipe system has been chosen as a model. It is Shown that after power failure the pressure at the pump outlet drops sharply, and to prevent reverse flow, either butterfly valve or check valve can be used. After the valve closure, pressure oscillates behind the valve. To weaken the pressure wave, it is recommended to install a servo-operated valve in a bypass Line around the pamp and the check valve.

  • PDF