• Title/Summary/Keyword: Butterworth

Search Result 124, Processing Time 0.03 seconds

Analysis of the Effects According to Changes in Impedance and Electrical Equivalent Circuit Modeling of a SONAR Transducer Considering Dual Resonance (이중 공진을 고려한 소나 트랜스듀서의 전기적 등가회로 모델링 및 임피던스 변동에 따른 효과 분석)

  • Mok, Hyung-Soo;Choi, Jae-Hyuk;Han, Soo-Hee;Park, Sang-Zoon;Kim, Sung-Joo;Heo, Jun-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.144-151
    • /
    • 2015
  • The present study proposes a method for modeling a SONAR transducer with dual resonance. The Butterworth van-Dyke (BVD) model, a conventional SONAR transducer modeling method, can model only one resonance point. Hence, to address its disadvantage and to model the dual resonance, a dual resonance BVD model consisting of two serial BVD models is proposed. The two BVD models are connected in a series, and each simulate resonance at low frequency and high frequency, which allows the modeling of two resonance points. Eight elements compose the equivalent circuit by connecting the BVD models in a series, which is twice as great as that of the existing BVD model. The element value of the dual resonance BVD model is extracted by using the particle swarm optimization method. Analysis was also performed to identify the effects of changes in the value of elements that compose the equivalent circuit on the impedance characteristics of the equivalent circuit through simulation in which element values varied.

Design of 3V CMOS Continuous-Time Filter Using Fully-Balanced Current Integrator (완전평형 전류 적분기를 이용한 3V CMOS 연속시간 필터 설계)

  • An, Jeong-Cheol;Yu, Yeong-Gyu;Choe, Seok-U;Kim, Dong-Yong;Yun, Chang-Hun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.28-34
    • /
    • 2000
  • In this paper, a continuous-time filter for low voltage and high frequency applications using fully-balanced current integrators is presented. As the balanced structure of integrator circuits, the designed filter has improved noise characteristics and wide dynamic range since even-order harmonics are cancelled and the input signal range is doubled. Using complementary current mirrors, bias circuits are simplified and the cutoff frequency of filters can be controlled easily by a single DC bias current. As a design example, the 3rd-order lowpass Butterworth filter with a leapfrog realization is designed. The designed fully-balanced current-mode filter is simulated and examined by SPICE using 0.65${\mu}{\textrm}{m}$ CMOS n-well process parameters. The simulation results show 50MHz cutoff frequency, 69㏈ dynamic range with 1% total harmonic distortion(THD), and 4㎽ power dissipation with a 3V supply voltage.

  • PDF

Study on R-peak Detection Algorithm of Arrhythmia Patients in ECG (심전도 신호에서 부정맥 환자의 R파 검출 알고리즘 연구)

  • Ahn, Se-Jong;Lim, Chang-Joo;Kim, Yong-Gwon;Chung, Sung-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4443-4449
    • /
    • 2011
  • ECG consists of various types of electrical signal on the heart, and feature point of these signals can be detected by analyzing the arrhythmia. So far, feature points extraction method for the detection of arrhythmia done in the many studies. However, it is not suitable for portable device using real time operation due to complicated operation. In this paper, R-peak were extracted using R-R interval and QRS width informations on patients. First, noise of low frequency bands eliminated using butterworth filter, and the R-peak was extracted by R-R interval moving average and QRS width moving average. In order to verify, it was experimented to compare the R-peak of data in MIT-BIH arrhythmia database and the R-peak of suggested algorithm. As a results, it showed an excellent detection for feature point of R-peak, even during the process of operation could be efficient way to confirm.

Comparison of Kinematic Variables of the Elite Woman's 100m Hurdler (엘리트 여자 100m 허들선수들의 운동학적 변인 비교)

  • Ryu, Jae-Kyun;Chang, Jae-Kwan;Yeo, Hong-Chul;Lim, Jung-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.149-156
    • /
    • 2007
  • The purpose of this study was to compare the world class women's hurdlers with kinematic variables Lee Yeon-Kyoung's in the 100m hurdle. Among korea elite female hurdler, Lee Yeon-Kyoung was participated as a subject. Eight JVC video cameras(GR-HD1KR) were used to film the performance of Lee Yeon-Kyoung at a frame rate of 60fields/s. The real-life three-dimensional coordinate data of digitized body landmarks were smoothed using a fourth order Butterworth low pass recursive digital filter with an estimated optimum cutoff frequency of 7.4Hz. After analyzing and comparing Lee Yeon Kyung's kinematic variables with the world top class hurdlers in the woman's 100m hurdle run, the following conclusions were obtained. 1. Lee should be able to increase the speed with over 5.4m/s from start to first hurdle and then maintain the speed range from 8.33m/s to 8.67m/s until 10th hurdle. Lee should have to maintain the speed with 8.51m/s from 10th hurdle to finish line. 2. Lee has to reach her maximum running speed at 5th hurdle and then has to shorten running time with 0.5sec between hurdles. 3. Lee should be able to run around 2.5sec from start to frist hurdle and then maintain under 1.00sec following phases. Lee should be able to maintain under 1.10sec from 10th hurdle to finish line. 4. Lee needs to control a consistent takeoff and landing distance pattern, Lee needs to lower the height of the center of gravity of the body with 0.33m when she clears the hurdles.

Evaluation of Consistency on Kinematic Factors in Women Javelin Throw (여자 창던지기 운동학적 요인의 일관성 평가)

  • Hong, Soon-Mo;Lee, Young-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.65-71
    • /
    • 2007
  • The purpose of this study was to investigate variability of kinematic factors affecting the record in women's javelin throwing. For this study, 8 female-javelin thrower participated in this experiment. The three digital video cameras (Sony, 120x) were used to record motions. Kwon3D 2.1 was used to process data and they were analyzed with Excell for factors. The sampling rate of a camera was 60Hz and shutter speed of a camera was 1/1000sec. The coordinate data were filtered using a fourth-order Butterworth low pass filtering with an estimated optimum cut-off frequency of 6Hz. The results were as follows: 1. From cross step to landing of delivery, the average velocities of CoM of non-dominant athletes were greater than dominant athletes and those of CoM of non-dominant athletes less than dominant athletes, but at release dominant athletes had a lower average velocity and a variability than non-dominant athletes. 2. From cross step to landing of delivery, the average throwing velocities and variabilities of a javelin of dominant athletes were greater than dominant athletes, but at release, dominant athletes had a higher velocity than dominant athletes and had a equal variability. 3. At every events, a forward or backward angles and variabilities of non-dominant athletes were greater than dominant athletes. 4. From cross step to landing of delivery, dominant athletes' elbow average angles were greater than non-dominant athletes and the variabilities of latter less than non-dominant athletes, but at release dominant athletes' variabilities were smaller than non-dominant athletes. 5. At landing of delivery, dominant athletes' knee average angles and variabilities of a supporting foot were a greater than non-dominant athletes, and at release, dominant athletes' knee average angles was a greater but variabilities less than non-dominant athletes. In conclusion, the dominant threw javelins fast while having stable postures and the range of elbow's angle large.

Lower Extremity Muscle Activity on the Obstacle Gait in Older Parkinson Diseases (파킨슨 환자들의 장애물 보행 향상을 위한 하지의 근육 활동 규명)

  • Lim, Bee-Oh;Kim, Mi-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.141-148
    • /
    • 2007
  • Falls associated with tripping over an obstacle can be dangerous, yet little is known about the strategies used for stepping over obstacles in older Parkinson disease. The purpose of this study was to investigate the lower extremity muscle activity on the obstacle gait according to obstacle height in older Parkinson diseases. The obstacle gait of 7 older Parkinson disease was examined during a 5.0 m approach to, and while stepping over, obstacles of 0, 25, 52, and 152mm. Seven pairs of surface electrodes(Noraxon MyoResearch, USA) were attached to the right-hand side of the body to monitor the adductor longus(AL), gluteus medius(GME), gluteus maximus(GMA), biceps femoris(BF), rectus femoris(RF), gastrocnemius(GA), tibialis anterior(TA). Electromyography data were filtered using a 10Hz to 350 Hz Butterworth band-pass digital filter and normalized to the maximum value in the analyzed phases. A one-way ANOVA for repeated measures was employed for selected electromyography variables to analyze the differences of the height of four obstacles. The results showed significant differences between 0.0mm and 25, 52, and 152mm obstacle height in TA and GA activities during the second phase(swing phase). But the more increase obstacle height, the more not increase the muscle activities. This means that the Parkinson disease stepping over obstacle inefficiency. To prevent and reduce the frequency of falls, elderly Parkinson disease maintained and improved their balance, muscular strength, neuromuscular control and mobility.

The Mechanical Analysis of the Hand spring forward and Salto forward straight with 3/2 Turn on the Vault (도마 손 짚고 몸펴 앞 공중 돌아 540도 비틀기의 운동역학적 분석)

  • Yeo, Hong-Chul;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.1
    • /
    • pp.13-26
    • /
    • 2004
  • The purpose of this study was to investigate the differences of the kinematical and the kinetical factors that calculated from preflight to preflight of salto forward straight 3/2 turn motion between skillers and less-skillers. four S-VHS video cameras operating at 60Hz were used to record the performances. Five elite male gymnasts were participated in this study as subjects. Three-dimensional coordinates of 21 body landmarks during each trial were collected using a Direct Linear Transformation method. The raw 3-D coordinates of the 21 body landmarks were smoothed using a second order lowpass, recursive Butterworth digital filter and a cutoff frequency of 10Hz. Load cells attached on the beneath of a board were used to attain the kinetic variables. It was found that the more angular momentum in the longitudinal axis, the less vertical velocity and these angular momentum effected the height of peak in the preflight. Also, it was revealed that the larger angular momentum in the medio-lateral axis was rather than it in the longitudinal axis to increase vertical height and rotation force of the body. For the reaction force of springboard, the vertical and the horizontal reaction force were 16.52BW and 3.45BW, respectively. It was found that the higher value of the vertical reaction force induced the faster vertical velocity and the higher an ar momentum. of the whole body center of gravity.

Design of 2V CMOS Continuous-Time Filter Using Current Integrator (전류 적분기를 이용한 2V CMOS 연속시간 필터 설계)

  • 안정철;유영규;최석우;윤창헌;김동용
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.9
    • /
    • pp.64-72
    • /
    • 1998
  • In this paper, the design of a current integrator for low-voltage, low-power, and high frequency applications using complementary high swing cascode current-mirror is presented. The proposed integrator decreases output current errors due to non-zero input resistance and non-infinite output resistance of the simple current integrator. As a design example, the 3rd order Butterworth lowpass filter is designed by a leapfrog method. Also, we apply the predistortion design method to reduce the magnitude distortion which occurs at a cutoff frequency by the undesirable phase shift of a lossless current integrator. The designed current-mode filter is simulated and examined by SPICE using 0.8$\mu\textrm{m}$ CMOS n-well process parameters. The simulation results show 20MHz cutoff frequency and 615㎼ power dissipation with a 2V power supply. And the cutoff frequency of the filters can be easily changed by the DC bias current.

  • PDF

Kinematical Aspects Gliding Technique in 500-m Speed Skaters: From Start to Seven Strokes

  • Ryu, Jae Kyun;Kim, Young Suk;Hong, Sung Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.333-341
    • /
    • 2016
  • Objective: The purpose of this study was to assess the consistency of the gliding and push-off motion for single leg skating from the first to fourteenth steps. We hypothesized that: 1) there would be no difference in stroke trajectory, step rate, and cycle rate between the left and right steps of gliding; and 2) there would be a difference in the resultant velocity of toe push-off and the horizontal velocity of the center of mass after six step push-offs. Method: The study included five male 500-m speed skaters (mean height, $1.80{\pm}0.02m$; mean weight, $76.8{\pm}3.96kg$; record, $35.83{\pm}0.30sec$; 100-m record, <9.97 sec). Data were collected from the first to fourteenth steps (40 m) and recorded using five digital JVC GR-HD1KR video cameras (Victor Co., Japan) operating at a sampling frequency of 60 fields/sec and shutter speed of 1/500 sec. For each film frame, the joint positions were digitized using the KWON3D motion analyzer. Position data were filtered with low-pass Butterworth $4^{th}$ order at the cut-off frequency of 7.4 Hz. Results: The right toe of the skating trajectories at $2^{nd}$, $5^{th}$, and $7^{th}$ strokes differed from those of the left toe. The angles of the right and left knee demonstrated unbalanced patterns from the flexion and extension legs. The step and cycle rates of the right and left leg differed from the start until 20 m. The resultant velocities of the toe at the push-off phase and of the body mass center diverged before the six push-offs. Conclusion: This study's findings indicate that the toe of skating trajectory on left and right sliding after push-off should maintain a symmetrical trajectory. The resultant velocity of toe push-off and horizontal velocity from the center of body need to be separated after about six step push-offs.

Quantitative Study of Annular Single-Crystal Brain SPECT (원형단일결정을 이용한 SPECT의 정량화 연구)

  • 김희중;김한명;소수길;봉정균;이종두
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.163-173
    • /
    • 1998
  • Nuclear medicine emission computed tomography(ECT) can be very useful to diagnose early stage of neuronal diseases and to measure theraputic results objectively, if we can quantitate energy metabolism, blood flow, biochemical processes, or dopamine receptor and transporter using ECT. However, physical factors including attenuation, scatter, partial volume effect, noise, and reconstruction algorithm make it very difficult to quantitate independent of type of SPECT. In this study, we quantitated the effects of attenuation and scatter using brain SPECT and three-dimensional brain phantom with and without applying their correction methods. Dual energy window method was applied for scatter correction. The photopeak energy window and scatter energy window were set to 140ke${\pm}$10% and 119ke${\pm}$6% and 100% of scatter window data were subtracted from the photopeak window prior to reconstruction. The projection data were reconstructed using Butterworth filter with cutoff frequency of 0.95cycles/cm and order of 10. Attenuation correction was done by Chang's method with attenuation coefficients of 0.12/cm and 0.15/cm for the reconstruction data without scatter correction and with scatter correction, respectively. For quantitation, regions of interest (ROIs) were drawn on the three slices selected at the level of the basal ganglia. Without scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.2 and 2.1, respectively. However, the ratios between basal ganglia and background were very similar for with and without attenuation correction. With scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.69 and 2.64, respectively. These results indicate that the attenuation correction is necessary for the quantitation. When true ratios between basal ganglia and background were 6.58, 4.68, 1.86, the measured ratios with scatter and attenuation correction were 76%, 80%, 82% of their true ratios, respectively. The approximate 20% underestimation could be partially due to the effect of partial volume and reconstruction algorithm which we have not investigated in this study, and partially due to imperfect scatter and attenuation correction methods that we have applied in consideration of clinical applications.

  • PDF