• 제목/요약/키워드: Bushing

검색결과 192건 처리시간 0.031초

발진주파수 및 전도도를 통한 오손도 자동측정 (Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency)

  • 최남호;구경완;이명섭;한상옥;정재기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

지진증폭현상을 고려한 철골구조 내 부싱의 내진성능평가 (Seismic Capacity Evaluation of Bushing on the Steel Structure with Earthquake Amplification)

  • 장정범;김정기;황경민;권기주;안재후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.349-350
    • /
    • 2007
  • 부싱은 지진에 취약한 전기설비 중의 하나이며, 이들 부싱은 특히 다른 전기기기 또는 철골 구조체에 설치되어 기기 또는 구조체의 지진증폭현상에 의한 증가된 지진가속도를 받게 된다. 따라서, 본 연구에서는 철골 구조체에 설치된 부싱을 대상으로 지진증폭현상을 규명하고, 이를 고려한 철골 구조체와 부싱의 내진성능을 평가하였다.

  • PDF

가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전 측정 (Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch)

  • 최수연;박찬용;박대원;김일권;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.476-477
    • /
    • 2007
  • This paper described the partial discharge (PD) measurement techniques for diagnosing gas-insulated switches in overhead power distribution system. A capacitive voltage probe to detect PD pulse was designed and fixed on the surface of a bushing. We also designed a coupling network to attenuate AC voltage by 270 dB, and a low-noise amplifier having the gain of 40 dB and 500 kHz~20 MHz 3 dB. From the calibration, it was calculated that the sensitivity of the measurement system was 0.94mV/pC. In the application experiment, we could measure a PD pulse of 45 pC.

  • PDF

차량동역학 해석에서 스태필라이저의 모델링 (Modeling of Stabilizer for Vehicle Dynamic Analysis)

  • 조병관;송성재
    • 한국정밀공학회지
    • /
    • 제13권10호
    • /
    • pp.30-35
    • /
    • 1996
  • Tires, bushings and stabilizers are the most difficult elements in vehicle modeling for dynamic analyses. Many studies were performed for tire modeling and the primitive data of bushing elements can be obtained from the suspension designer, but there are few things for stabilizer. This paper presents simulation results for the 3 kinds of stabilizer model with the multi-body dynamic analysis program ADAMS. Each simulation result was compared with the vehicle test result, and the stabilizer model was proposed to analyze the vehicle behaviors precisely.

  • PDF

Massless Links with External Forces and Bushing Effect for Multibody Dynamic Analysis

  • Sohn, Jeong-Hyun;Yoo, Wan-Suk;Hong, Keum-Shik;Kim, Kwang-Suk
    • Journal of Mechanical Science and Technology
    • /
    • 제16권6호
    • /
    • pp.810-818
    • /
    • 2002
  • When the contribution of lightweight components to the total energy of a system is small, tole inertia effects are sometimes ignored by replacing them to massless links. For example, a revolute-spherical massless link generates two kinematic constraint equations between adjacent bodies and allows four relative degrees of freedom. In this paper, to implement a massless link systematically in a computer program using the velocity transformation technique, the velocity transformation matrix of massless links is derived and numerically implemented. The velocity transformation matrix for a revolute-spherical massless link and a revolute-universal massless link are appeared as a 6$\times$4 matrix and a 6$\times$3 matrix, respectively. A massless link model in a suspension composite joint transmitting external forces is also developed and the numerical efficiency of the proposed model is compared to a conventional multibody model. For a massless link transmitting external forces, forces acting on links are resolved and transmitted to the attached points with a quasi-static assumption. Numerical examples are presented to verify the formulation.

자동차 와이퍼 링키지의 진동해석을 위한 동역학 모델링 (Automotive Windshield Wiper Linkage Dynamic Modeling for Vibration Analysis)

  • 이병수
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.465-472
    • /
    • 2008
  • An automotive windshield wiper system is modeled mainly for vibration analysis purpose. The model is composed of solid links, ideal joints, imperfect joints to simulate unavoidable manufacturing defects and bushings having stiffness, contact between a wiper blade and a wind screen glass, friction, a spring and an actuator. Main stream of wiper dynamics analysis has been obtaining a closed form of system of equations using Newton's or Lagrange's formula and doing a numerical simulation study to understand and predict the behavior of it. However, the modeling process is complex since a wiper system is of multibody and a contact problem occurs. When imperfection, such as dead zone of a joint and stiffness of a rubber bushing, should be included, the added complexity makes the modeling difficult. Since the imperfection is understood as main cause of problematic vibration, the dynamics model of a wiper system aiming vibration analysis should include such unavoidable manufacturing defects in the model. An open form of dynamic model of a automotive windshield wiper system with imperfect joints using a commercial software is obtained and a simulation analyssis is conducted for vibration reduction study.

염무-열 반복 열화에 따른 실리콘 고무의 표면열화특성변화 (The change of surface degradation properties of silicone rubber for salt fog)

  • 오태승;이청;박수길;류부형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.886-889
    • /
    • 2001
  • Silicone rubber is being used for the housing material of outdoor high voltage insulators such as composite insulator, bushing, surge arrestor and cable terminator because of good tracking and erosion resistance, good hydrophobicity and recovery of hydrophobicity and chemical stability. But, the leakge current occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current is important to estimate the condition of the silicone rubber surface. In this paper, aging characteristics of silicone rubber used for outdoor insulation have been hydrophobicity of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, A1$_2$O$_3$$.$3H$_2$O) filler contents. The experimental results show that a higher peak leakage current and to raise a long time for tracking with increasing amount of ATH by the salt fog and heat recycle ageing.

  • PDF

가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전의 측정 (Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch)

  • 길경석;박대원;최수연;김일권;박찬용
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.85-89
    • /
    • 2008
  • An objective of this paper is to develop a partial discharge (PD) measurement device for monitoring gas insulated switches installed in power distribution system. A capacitive voltage probe was studied and designed to detect PD pulse without an electrical connection. The PD measurement device consists of the capacitive voltage probe attached outside of a bushing, a coupling network which attenuates AC voltage by 270 dB, and a low noise amplifier with the gain of 40 dB in ranges of 500 kHz${\sim}$20 MHz. The sensitivity of the prototype device calculated by a calibrator was 1.98 m V /pc. An application experiment was carried out in a 25.8 kV gas insulated switch and the peak pulse of 76.7 pC was detected. From the experimental results, it is expected that the PD measurement device can be applied to online monitoring system of gas insulated switches.

서스펜션 성능 확보를 위한 고강성 차페 개발 프로세스 연구 (A Study on the Development of High Stiffness Body for Suspension Performance)

  • 김기창;김찬묵
    • 한국소음진동공학회논문집
    • /
    • 제15권7호
    • /
    • pp.799-805
    • /
    • 2005
  • This paper describes the development process of high stiffness body for ride and handling performance. High stiffness and light weight vehicle is a major target in the refinement of Passenger cars to meet customers' contradictable requirements between ride and handling performance and fuel economy This paper describes the analysis approach process for high stiffness body through the data level of body stiffness. According to the frequency band. we can suggest the design guideline about lg cornering static stiffness, torsional and lateral stiffness, body attachment stiffness. The ride and handling characteristic of a vehicle Is significantly affected by vibration transferred to the body through the chassis mounting points from front and rear suspension. It is known that body attachment stiffness is an important factor of ride and handling performance improvement. And high stiffness helps to improve the flexibility of bushing rate tuning between handling and road noise. It makes possible to design the good handling performance vehicle and save vehicles to be used in tests by using mother car at initial design stage. These improvements can lead to shortening the time needed to develop better vehicles.

Friction Bushing용 복합재료의 미끄럼 마찰마모특성에 관한 연구 (Sliding Wear and Friction Properties of Composite Materials for Friction Bushing)

  • 이한영;허대홍;김태준;조용재;조범래;허만대
    • Tribology and Lubricants
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2006
  • The sliding friction and wear properties of mineral fiber reinforced composite(MF) and glass fiber reinforced composites(GF) are investigated to clarify their field of use and the role of each fiber in friction material. Friction and wear test reveals that GF composite has better wear resistance even though with low friction coefficient, comparing with MF composite. Glass fiber strengthen effectively the matrix and may absorb friction energy to convert it into the fracture energy of them, as well as its lubricative role. However, mineral fiber in MF composite is too small to strengthen the matrix. Then MF composite are easily plowed and worn out by asperity on counter material. Friction coefficient of MF composite is higher friction coefficient than that of GF composite and varied widely with test.