• 제목/요약/키워드: Busbar distribution system

검색결과 9건 처리시간 0.018초

Applicability Comparison of Transmission Line Parameter Extraction Methods for Busbar Distribution Systems

  • Hasirci, Zeynep;Cavdar, Ismail Hakki;Ozturk, Mehmet
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.586-593
    • /
    • 2017
  • Modeling busbar distribution system as a transmission line is an important subject of power line communication in the smart grid concept. This requires extraction of busbar RLGC parameters, accurately. In this study, a comparison is made between conventional and modified method for the aspect of optimum RLGC parameters extraction in the 1 MHz to 50 MHz frequency band. The usefulness of these methods is shown both in time and frequency-domain analysis. The frequency-domain analyzes show that the inherent power of modified method can eliminate the errors especially due to the discontinuities arise in conventional method. This makes the modeling approach of modified method more advantageous for the busbars due to its robustness against disturbances in the S-parameters measurements which cannot be eliminated with the calibration procedure. On the other hand, time-domain simulations show that the transmission line representation of the modified method is closer to physical reality by handling causality issues.

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.

부스바 접촉 상태 및 온도 감지 시스템 설계 및 구현 (A Design and Implementation of Busbar Joint and Temperature Measurement System)

  • 이영동;정성학
    • 한국정보통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.379-385
    • /
    • 2017
  • 일반적으로 배전반, 분전반, 전동기제어반(Motor Control Center; MCC)은 집단거주지역, 빌딩, 학교, 공장, 항만, 공항, 상하수 처리장, 변전소, 중공업 플랜트 등의 광범위한 전력 수용가에 설치되어 특고압의 전력을 해당 설비들에 요구되는 전압으로 변환하여 공급하는데 사용된다. 이와 같은 배전반, 분전반, MCC에 포함되는 전기설비의 사고는 부스바 접촉부의 열화에 의한 사고, 부스바의 접점 및 연결 부위에서의 접촉 불량에 의한 사고, 부스바 접촉부의 과열현상에 의한 사고로 구분된다. 본 논문에서는 부스바 접촉부의 볼트 및 너트의 풀림상태, 접촉부 열화 측정이 가능하며, 정밀 가변저항을 이용하여 저항값의 변화에 따라 볼트 체결상태 감지 및 비접촉식 적외선 센서를 사용하여 부스바 접촉부 온도 감지 시스템을 설계하고 구현하였다. 부스바 접촉부 체결상태 감지를 위한 가변저항을 이용한 실험을 수행한 결과 볼트와 너트를 완전히 체결시키면 가변저항 값은 감소하였으며, 최대 오차범위는 0.1mm의 결과를 보였다. 또한, 부스바 접촉 저항값 변화에 따라 접촉부 온도가 $27.3^{\circ}C$에서 $69.3^{\circ}C$로 상승하는 결과를 확인하였다.

부스바 접촉부 체결상태 모니터링 시스템 설계 (Design of Busbar Joint Condition Monitoring System)

  • 정성학;이영동
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.823-824
    • /
    • 2016
  • 일반적으로 배전반, 분전반, 전동기제어반(Motor Control Center;MCC)은 집단거주지역, 빌딩, 학교, 공장, 항만, 공항, 상하수 처리장, 변전소, 중공업 플랜트 등의 광범위한 전력 수용가에 설치되어 특고압의 전력을 해당 설비들에 요구되는 전압으로 변환하여 공급하는데 사용된다. 이와 같은 배전반, 분전반, MCC에 포함되는 전기설비의 사고는 부스바 접속부의 열화에 의한 사고, 부스바의 접점 및 연결 부위에서의 접촉 불량에 의한 사고, 부스바 접속부의 과열 현상에 의한 사고로 구분된다. 본 논문에서는 부스바 접촉부의 볼트 및 너트의 풀림상태, 접촉부 열화 측정이 가능하며, 배전반 내부온도와 부스바 온도를 측정하여 추이변화에 대한 감시기능이 있는 부스바 접촉부 체결상태 모니터링 시스템을 제안한다. 제안된 시스템은 정량적인 부스바 체결상태 검출과 부스바 현재온도 검출의 이중적인 센싱에 의해 부스바 접촉부 정상여부 판별이 가능하여 전기설비 사고를 줄일 수 있을 것으로 기대된다.

  • PDF

Bus Reconfiguration Strategy Based on Local Minimum Tree Search for the Event Processing of Automated Distribution Substations

  • Ko Yun-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.177-185
    • /
    • 2005
  • This paper proposes an expert system that can enhance the accuracy of real-time bus reconfiguration strategy by adopting the local minimum tree search method and that can minimize the spreading effect of the fault by considering the operating condition when a main transformer fault occurs in an automated substation. The local minimum tree search method is used to expand the best-first search method. This method has the advantage that it can improve the solution performance within the limits of the real-time condition. The inference strategy proposed expert system consists of two stages. The first stage determines the switching candidate set by searching possible switching candidates starting from the main transformer or busbar related to the event. The second stage determines the rational real-time bus reconfiguration strategy based on heuristic rules from the obtained switching candidate set. Also, this paper proposes generalized distribution substation modeling using graph theory, and a substation database based on the study results is designed.

자동화된 변전소의 이벤트 발생시 준최적 탐색법에 기반한 모선 재구성 전략의 개발 (Bus Reconfiguration Strategy Based on Local Minimum Tree Search for the Event Processing of Automated Distribution Substation)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권10호
    • /
    • pp.565-572
    • /
    • 2004
  • This paper proposes an expert system which can enhance the accuracy of real-time bus reconfiguration strategy by adopting local minimum tree search method and minimize the spreading effect of the fault by considering totally the operating condition when a main transformer fault occurs in the automated substation. The local minimum tree search method to expand the best-first search method. This method has an advantage which can improve the performance of solution within the limits of the real-time condition. The inference strategy proposed expert system consists of two stages. The first stage determines the switching candidate set by searching possible switching candidates starting from the main transformer or busbar related to the event. And, second stage determines the rational real-time bus reconfiguration strategy based on heuristic rules for the obtained switching candidate set. Also, this paper studies the generalized distribution substation modelling using graph theory and a substation database is designed based on the study result. The inference engine of the expert system and the substation database is implemented in MFC function of Visual C++. Finally, the performance and effectiveness of the proposed expert system is verified by comparing the best-first search solution and local minimum tree search solution based on diversity event simulations for typical distribution substation.

전력계통(電力系統)의 상정(想定)사고(事故)에 따른 선로(線路)의 과부하(過負荷) 해소(解消) 대책(對策) (The Alleviation Countermeasures of Line Overloads Due To a Contingency Occured in Power System)

  • 정제길;노신홍;박규홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.432-436
    • /
    • 1991
  • This paper presents a new algorithm for the countermeasure to alleviate without shedding system loads the line overloads due to contingency in power system. This method for relieving by line switching is based on obtaining the line outage distribution factors - the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of same other line in the power system. These factors are made up of the elements of Bus Reactance Matrix and branch reactances. In this paper a fast algorithm and program is presented for obtaining only the required Bus Reactance elements which corresponds to a non - zero elements of Bus Admittance Matrix and elements of columns which correspond to two terminal Buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on the 6 busbar test system

  • PDF

IED를 기반으로 하는 디지털 수배전반의 지적추론기반 운전제어 솔루션 설계 (The Design of Operation and Control Solution with Intelligent Inference Capability for IED based Digital Switchgear Panel)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, DSPOCS(Digital Switchgear-Panel Operation and Control Solution) is designed, which is the intelligent inference based operation and control solution to obtain the safety and reliability of electric power supply in substation based on IED. DSPOCS is designed as a scheduled monitoring and control task and a real-time alarm inference task, and is interlinked with BRES(Bus Reconfiguration Expert System) in the required case. The intelligent alarm inference task consists of the alarm knowledge generation part and the real-time pattern matching part. The alarm knowledge generation part generates automatically alarm knowledge from DB saves it in alarm knowledge base. On the other hand, the pattern matching part inferences the real-time event by comparing the real-time event information furnished from IEDs of substation with the patterns of the saved alarm knowledge base.; Especially, alarm knowledge base includes the knowledge patterns related with fault alarm, the overload alarm and the diagnosis alarm. In order to design the database independently in substation structure, busbar is represented as a connectivity node which makes the more generalized graph theory possible. Finally, DSPOCS is implemented in MS Visual $C^{++}$, MFC, the effectiveness and accuracy of the design is verified by simulation study to the typical distribution substation.

고도화된 자동화 변전소의 사고복구 지원을 위한 지식학습능력을 가지는 전문가 시스템의 개발 (Development of An Expert system with Knowledge Learning Capability for Service Restoration of Automated Distribution Substation)

  • 고윤석;강태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권12호
    • /
    • pp.637-644
    • /
    • 2004
  • This paper proposes an expert system with the knowledge learning capability which can enhance the safety and effectiveness of substation operation in the automated substation as well as existing substation by inferring multiple events such as main transformer fault, busbar fault and main transformer work schedule under multiple inference mode and multiple objective mode and by considering totally the switch status and the main transformer operating constraints. Especially inference mode includes the local minimum tree search method and pattern recognition method to enhance the performance of real-time bus reconfiguration strategy. The inference engine of the expert system consists of intuitive inferencing part and logical inferencing part. The intuitive inferencing part offers the control strategy corresponding to the event which is most similar to the real event by searching based on a minimum distance classification method of pattern recognition methods. On the other hand, logical inferencing part makes real-time control strategy using real-time mode(best-first search method) when the intuitive inferencing is failed. Also, it builds up a knowledge base or appends a new knowledge to the knowledge base using pattern learning function. The expert system has main transformer fault, main transformer maintenance work and bus fault processing function. It is implemented as computer language, Visual C++ which has a dynamic programming function for implementing of inference engine and a MFC function for implementing of MMI. Finally, it's accuracy and effectiveness is proved by several event simulation works for a typical substation.