• 제목/요약/키워드: Burn Risk

검색결과 68건 처리시간 0.028초

웨어러블 스마트기기의 표준화 및 시험인증 연구 (Study of Standardization and Test Certification for Wearable Smart Devices)

  • 한태수;김덕기;권오영;좌성훈
    • 마이크로전자및패키징학회지
    • /
    • 제23권4호
    • /
    • pp.11-18
    • /
    • 2016
  • Today, wearable technology products are used in a wide range of consumer, healthcare, bio-medical, and industrial applications. The market for wearable technology products is expected to increase dramatically over the next several years. In addition, concerns for safety, performance and reliability of wearable products keep increasing and will be essential for widespread acceptance in the marketplace. Wearable smart devices, which are generally in contact with the human body and skin, are exposed to the risk of the electric shock, burn, and explosion. Therefore, the standardization of wearable devices in terms of human safety and reliability should be very important. Furthermore, the development of test method and test certification of the wearable products will be one of the key technology for mass production. Such standardization and certification will help consumers to choose the safest and best quality wearable devices and allow manufacturers to prove the safety and quality of their products, thereby helping them to gain a competitive technology. This paper discusses the current status of the wearable smart devices as well as the standardization and test certification applicable to wearable technology products.

유리 복직근 및 복직근피판술을 이용한 사지의 재건술 (Reconstruction of the Extremity Injury using by Free Rectus Abdoninis Muscle or Myocutaneous Flap)

  • 안기영;장경수;한동길
    • Archives of Reconstructive Microsurgery
    • /
    • 제4권1호
    • /
    • pp.23-32
    • /
    • 1995
  • Severe upper and lower extremity trauma may result in soft tissue loss with exposed bone and the subsequence of risk of chronic osteomyelitis or malunion of fracture fragments. Such injuries present a major reconstructive problem. But Since the introduction of microsugical technique, free muscle and myocutaneous flaps were employed to provide coverage of severely injured defects. Since Tai and Hasegawa(1974) first reported a breast reconstruction using by rectus abdominis myocuraneous flap, the free rectus myocutaneous flap has been widely employed for breast reconstuction, head and neck reconstruction, and extremity reconstruction in these days. The authors present their successful experience with free rectus abdominis muscle and rectus abdominis myocutaneous flaps for upper and low extremity reconstruction. From Nov. 94, to May 95, Five cases of severely injured extremites due to trauma or contact burn were treated with free rectus abdominis muscle flap or free rectus abdominis myocutaneous flap. All flaps except 1 case were survived without severe complications. As free muscle or myocutaneous flap, the free rectus abdominis flap has the advantages of a reliable pedicle, easy dissection, and an acceptable donor site, so it seems logical to apply the free rectus abdominis flap to apply in upper and lower extremity reconstruction.

  • PDF

마졸린씨 궤양에서 발생한 암육종의 증례 보고 (A Case of Carcinosarcoma of Skin Developed on Marjolin's Ulcer)

  • 문유진;김준혁;이영만;오미혜;조현득
    • Archives of Plastic Surgery
    • /
    • 제37권1호
    • /
    • pp.79-82
    • /
    • 2010
  • Purpose: Carcinosarcomas are rare neoplasms in which both malignant epithelial and mesenchymal elements are identified. We have found only twenty one cases of primary cutaneous carcinosarcoma in the English language literature. Therefore it has been difficult to diagnosis because its unclear etiology and low frequency. Methods: A 31-year-old young man with a protruding mass on his ankle dorsum was examined. The tumor was $7{\times}6{\times}3\;cm$ sized and arose from a burn scar. The mass was wide excised and applied split thickness skin graft. Characteristic pathologic finding was a mixture of squamous cell carcinoma and malignant fibrous histiocytoma. Results: Three months after the operation, the patient died of multiple metastasis to the liver, lung and finally of sepsis despite adjuvant chemotherapy and adjuvant radiotherapy. Conclusion: If a metastatic cutaneous carcinosarcoma is diagnosed, wide excision is required. There should be more aggressive management to minimize the risk of recurrence. Further research into the etiology and pathophysiology of the disease and a more careful differential diagnosis may allow improvement in treatment.

흡인성 화상을 입은 환자에서 관찰된 후두점막의 악성변화 1례 (A Case of Malignant Transformation of Layngeal Mucosa after Inhalation Injury 25 Years Ago)

  • 이재영;이길준;안동빈;손진호
    • 대한후두음성언어의학회지
    • /
    • 제28권2호
    • /
    • pp.144-147
    • /
    • 2017
  • Laryngeal neoplasm is the second most common malignancy of the upper aerodigestive tract. About 85% to 95% of laryngeal malignancies are squamous cell carcinoma that arises from the epithelial lining of the larynx. The exact cause of laryngeal neoplasm is unknown, but certain risk factors can affect the chances of developing it. Chronic inflammation is a mutagen factor confirmed in the carcinogenesis of various tumor. Inhalation injuries cause histopathologic damage to laryngeal mucosa and inflammation change. This long term inflammation may leads to the development of dysplasia and malignant transformation. Recently, we experienced a case of malignant transformation of laryngeal mucosa after inhalation injury patient 25 years ago. Herein, we reported this rare case and review the relevant literature.

  • PDF

고체 추진기관 둔감화 점화 장치의 반응 (Reaction of an Insensitive Munitions(IM) Igniter for Solid Propulsion System)

  • 류병태;이도형;류백능;최홍석
    • 한국추진공학회지
    • /
    • 제16권6호
    • /
    • pp.85-91
    • /
    • 2012
  • 본 논문은 우발적 화재에 노출된 고체 추진기관의 화재 위협이나 폭발을 파이로 센서가 자동적으로 감지하여 추진기관이 안전하게 연소되게 하는 둔감 점화 장치의 반응을 연구한 결과다. 완속 가열 시험은 HTPB 추진제가 충전된 로켓 모터에 열감지형 점화기를 장착하여 MIL-STD-2105D 규정에 따라 수행하였다. 얻어진 점화 온도는 약 $140^{\circ}C$였으며, 이는 "연소 반응" 등급에 해당되었다. Kissinger 식으로 구한 둔감 점화 장치 신호 화약의 자동 점화 온도는 $165.5^{\circ}C$였다.

일 지역 농업인의 농작업 재해사고 (Agricultural Accidents in Farm Workers)

  • 김한숙;최연희
    • 지역사회간호학회지
    • /
    • 제18권4호
    • /
    • pp.643-650
    • /
    • 2007
  • Purpose: This study was to obtain information regarding to agricultural accidents in farm workers in the Kyungpook area. Methods: A questionnaire survey was carried out for 528 workers from the 1st to 31st of March, 2007. Frequency, percentage, mean and chi-square test with the SPSS program were used to analyze the data. Results: The causes of agricultural accidents include falling(29.0%), overseeing(18.9%), traffic accident(17.4%), putting between machinery(11.7%), crashing(5.3%), fire (0.6%) in the order of frequency. Injuries from agricultural accidents include fracture(44.7%) cerebral bleeding (10.4%), amputation(7.0%), airway obstruction (2.3%) burn(1.9%), drug addiction(1.9%) in the order of frequency. The largest proportion of the subjects of hospital treatment were in their 50s and belonged to the group of high-level economic state. Agricultural machinery collision was the most frequent cause among the subjects of hospital treatment. Conclusion: These results suggest that carelessness can be a potential risk factor for agricultural accidents in farm workers. These findings may give useful information for developing agricultural accident prevention programs for farm workers.

  • PDF

The use of negative-pressure wound therapy over a cultured epithelial autograft for full-thickness wounds secondary to purpura fulminans in an infant

  • Goh, Benjamin Kah Liang;Chua, Alvin Wen Choong;Chew, Khong Yik;Kang, Gavin Chun-Wui;Chiang, Li-Wei;Tan, Bien-Keem;Ramachandran, Savitha
    • Archives of Plastic Surgery
    • /
    • 제48권3호
    • /
    • pp.338-343
    • /
    • 2021
  • Purpura fulminans is a serious condition that can result in severe morbidity in the pediatric population. Although autologous skin grafts remain the gold standard for the coverage of partial- to full-thickness wounds, they have several limitations in pediatric patients, including the lack of planar donor sites, the risk of hemodynamic instability, and the limited graft thickness. In Singapore, an in-house skin culture laboratory has been available since 2005 for the use of cultured epithelial autografts (CEAs), especially in burn wounds. However, due to the fragility of CEAs, negative-pressure wound therapy (NPWT) dressings have been rarely used with CEAs. With several modifications, we report a successful case of NPWT applied over a CEA in an infant who sustained 30% total body surface area full-thickness wounds over the anterior abdomen, flank, and upper thigh secondary to purpura fulminans. We also describe the advantages of using NPWT dressing over a CEA, particularly in pediatric patients.

Radiofrequency in arthroscopic shoulder surgery: a systematic review

  • Neeraj Vij;Joseph N. Liu;Nirav Amin
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.423-437
    • /
    • 2023
  • Background: Radiofrequency has seen an increase in use in orthopedics including cartilage lesion debridement in the hip and knee as well as many applications in arthroscopic shoulder surgery. The purpose of this systematic review is to evaluate the safety and usage of radiofrequency in the shoulder. Methods: This systematic review was registered with PROSPERO (international registry) and followed the preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) guidelines. Embase and PubMed were searched using: "shoulder," "rotator cuff," "biceps," "acromion" AND "monopolar," "bipolar," "ablation," "coblation," and "radiofrequency ablation." The title and abstract review were performed independently. Any discrepancies were addressed through open discussion. Results: A total of 63 studies were included. Radiofrequency is currently utilized in impingement syndrome, fracture fixation, instability, nerve injury, adhesive capsulitis, postoperative stiffness, and rotator cuff disease. Adverse events, namely superficial burns, are limited to case reports and case series, with higher-level evidence demonstrating safe use when used below the temperature threshold. Bipolar radiofrequency may decrease operative time and decrease the cost per case. Conclusions: Shoulder radiofrequency has a wide scope of application in various shoulder pathologies. Shoulder radiofrequency is safe; however, requires practitioners to be cognizant of the potential for thermal burn injuries. Bipolar radiofrequency may represent a more efficacious and economic treatment modality. Safety precautions have been executed by institutions to cut down patient complications from shoulder radiofrequency. Future research is required to determine what measures can be taken to further minimize the risk of thermal burns.

Meek Micrografting Technique for Reconstruction of Extensive Necrotizing Fasciitis of the Anterior Abdomen and Bilateral Femoral Region: A Case Report

  • Jyi Cheng Ng;Ahmad Ibrahim Ahmad Zaidi;Jun De Lee;Mohd Faisal Jabar
    • Archives of Plastic Surgery
    • /
    • 제50권6호
    • /
    • pp.610-614
    • /
    • 2023
  • Necrotizing fasciitis is an uncommon yet fatal soft tissue infection. Current recommended treatment includes antibiotics with repeat surgical exploration and wound debridement followed by reconstruction. In burn patients, the Meek micrograft has demonstrated a higher true expansion ratio, faster reepithelialization rate, more resilient toward infection, and reduced risk of graft failure as compared with meshed graft. To our best knowledge, the use of Meek micrografting technique in reconstruction of postdebridement wounds of necrotizing fasciitis has not been reported. Hereby, we present a case of a 57-year-old gentleman who was referred to us for wound reconstruction after surgical debridement of Fournier's gangrene and extensive necrotizing fasciitis involving the anterior abdomen and bilateral femoral region. Meek micrografting technique was used to reconstruct the anterior abdomen as the wound bed was large. Although the graft was complicated with a small area of localized infection, it did not spread across the entire graft and was successfully treated with topical antibiotics and regular wound dressing. In our case, wound reconstruction using Meek micrografting technique in a patient with extensive necrotizing fasciitis was successful and showed positive outcome. Therefore, we suggest further studies to be conducted to investigate the applications and outcomes of the Meek micrografting technique, especially in patients with extensive wound bed and limited donor site availability.

Neutronic optimization of thorium-based fuel configurations for minimizing slightly used nuclear fuel and radiotoxicity in small modular reactors

  • Nur Anis Zulaikha Kamarudin;Aznan Fazli Ismail;Mohamad Hairie Rabir;Khoo Kok Siong
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2641-2649
    • /
    • 2024
  • Effective management of slightly used nuclear fuel (SUNF) is crucial for both technical and public acceptance reasons. SUNF management, radiotoxicity risk, and associated financial investment and technological capabilities are major concerns in nuclear power production. Reducing the volume of SUNF can simplify its management, and one possible solution is utilizing small modular reactors (SMR) and advanced fuel designs like those with thorium. This research focuses on studying the neutronic performance and radionuclide inventory of three different thorium fuel configurations. The mass of fissile material in thorium-based fuel significantly impacts Kinf, burn-up, and neutron energy spectrum. Compared to uranium, thorium as a fuel produces far fewer transuranic elements and less long-lived fission products (LLFPs) at the end of the core cycle (EOC). However, certain fission product elements produced from thorium-based fuel exhibit higher radioactivity at the beginning of the core cycle (BOC). Physical separation of thorium and uranium in the fuel block, like seed-and-blanket units (SBU) and duplex fuel designs, generate less radioactive waste with lower radioactivity and longer cycle lengths than homogeneous or mixed thorium-uranium fuel. Furthermore, the SBU and duplex feel designs exhibit comparable neutron spectra, leading to negligible differences in SUNF production between the two.