DOI QR코드

DOI QR Code

Radiofrequency in arthroscopic shoulder surgery: a systematic review

  • Neeraj Vij (Department of Orthopedic Surgery, University of Arizona College of Medicine) ;
  • Joseph N. Liu (Department of Orthopedic Surgery, Keck Hospital of the University of Southern California) ;
  • Nirav Amin (Premier Orthopaedic)
  • Received : 2022.06.19
  • Accepted : 2022.09.16
  • Published : 2023.12.01

Abstract

Background: Radiofrequency has seen an increase in use in orthopedics including cartilage lesion debridement in the hip and knee as well as many applications in arthroscopic shoulder surgery. The purpose of this systematic review is to evaluate the safety and usage of radiofrequency in the shoulder. Methods: This systematic review was registered with PROSPERO (international registry) and followed the preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) guidelines. Embase and PubMed were searched using: "shoulder," "rotator cuff," "biceps," "acromion" AND "monopolar," "bipolar," "ablation," "coblation," and "radiofrequency ablation." The title and abstract review were performed independently. Any discrepancies were addressed through open discussion. Results: A total of 63 studies were included. Radiofrequency is currently utilized in impingement syndrome, fracture fixation, instability, nerve injury, adhesive capsulitis, postoperative stiffness, and rotator cuff disease. Adverse events, namely superficial burns, are limited to case reports and case series, with higher-level evidence demonstrating safe use when used below the temperature threshold. Bipolar radiofrequency may decrease operative time and decrease the cost per case. Conclusions: Shoulder radiofrequency has a wide scope of application in various shoulder pathologies. Shoulder radiofrequency is safe; however, requires practitioners to be cognizant of the potential for thermal burn injuries. Bipolar radiofrequency may represent a more efficacious and economic treatment modality. Safety precautions have been executed by institutions to cut down patient complications from shoulder radiofrequency. Future research is required to determine what measures can be taken to further minimize the risk of thermal burns.

Keywords

References

  1. Anderson SR, Faucett SC, Flanigan DC, Gmabardella RA, Amin NH. The history of radiofrequency energy and Coblation in arthroscopy: a current concepts review of its application in chondroplasty of the knee. J Exp Orthop 2019;6:1. 
  2. Lu Y, Zhang Q, Zhu Y, Jiang C. Is radiofrequency treatment effective for shoulder impingement syndrome?: a prospective randomized controlled study. J Shoulder Elbow Surg 2013;22:1488-94. 
  3. Huynh V, Barbier O, Bajard X, Bouchard A, Ollat D, Versier G. Subacromial temperature profile during bipolar radiofrequency use in shoulder arthroscopy: comparison of Coblation® vs. VAPR®. Orthop Traumatol Surg Res 2017;103:489-91. 
  4. Peng L, Li Y, Zhang K, et al. The time-dependent effects of bipolar radiofrequency energy on bovine articular cartilage. J Orthop Surg Res 2020;15:106. 
  5. Kosy JD, Schranz PJ, Toms AD, Eyres KS, Mandalia VI. The use of radiofrequency energy for arthroscopic chondroplasty in the knee. Arthroscopy 2011;27:695-703. 
  6. Schenker ML, Philippon MJ. The role of flexible radiofrequency energy probes in hip arthroscopy. Tech Orthop 2005;20:37-44. 
  7. Hayashi K, Markel MD. Thermal capsulorrhaphy treatment of shoulder instability: basic science. Clin Orthop Relat Res 2001;(390):59-72. 
  8. Hawkins RJ, Krishnan SG, Karas SG, Noonan TJ, Horan MP. Electrothermal arthroscopic shoulder capsulorrhaphy: a minimum 2-year follow-up. Am J Sports Med 2007;35:1484-8. 
  9. D'Alessandro DF, Bradley JP, Fleischli JE, Connor PM. Prospective evaluation of thermal capsulorrhaphy for shoulder instability: indications and results, two- to five-year follow-up. Am J Sports Med 2004;32:21-33. 
  10. Cvetanovich GL, Leroux TS, Bernardoni ED, et al. Clinical outcomes of arthroscopic 360° capsular release for idiopathic adhesive capsulitis in the lateral decubitus position. Arthroscopy 2018;34:764-70. 
  11. Li T, Yang ZZ, Deng Y, Xiao M, Jiang C, Wang JW. Indirect transfer of the sternal head of the pectoralis major with autogenous semitendinosus augmentation to treat scapular winging secondary to long thoracic nerve palsy. J Shoulder Elbow Surg 2017;26:1970-7. 
  12. Thompson SR, Lebel ME. Use of a hip arthroscopy flexible radiofrequency device for capsular release in frozen shoulder. Arthrosc Tech 2012;1:e75-8. 
  13. Arce G. Primary frozen shoulder syndrome: arthroscopic capsular release. Arthrosc Tech 2015;4:e717-20. 
  14. Cvetanovich GL, Leroux T, Hamamoto JT, Higgins JD, Romeo AA, Verma NN. Arthroscopic 360° capsular release for adhesive capsulitis in the lateral decubitus position. Arthrosc Tech 2016;5:e1033-8. 
  15. Parada SA, Shaw KA. Graft transfer technique in arthroscopic posterior glenoid reconstruction with distal tibia allograft. Arthrosc Tech 2017;6:e1891-5. 
  16. Boutsiadis A, Chen S, Jiang C, Lenoir H, Delsol P, Barth J. Long head of the biceps as a suitable available local tissue autograft for superior capsular reconstruction: "the Chinese way". Arthrosc Tech 2017;6:e1559-66.
  17. Saithna A, Longo A, Leiter J, MacDonald P, Old J. Biceps tenoscopy: arthroscopic evaluation of the extra-articular portion of the long head of biceps tendon. Arthrosc Tech 2016;5:e1461-5. 
  18. Su WR, Ling FY, Hong CK, Chang CH, Chung KC, Jou IM. An arthroscopic technique for long head of biceps tenodesis with double knotless screw. Arthrosc Tech 2015;4:e375-8. 
  19. Valenti P, Benedetto I, Maqdes A, Lima S, Moraiti C. "Relaxed" biceps proximal tenodesis: an arthroscopic technique with decreased residual tendon tension. Arthrosc Tech 2014;3:e639-41. 
  20. Lemos D, Esquivel A, Duncan D, Marsh S, Lemos S. Outlet biceps tenodesis: a new technique for treatment of biceps long head tendon injury. Arthrosc Tech 2013;2:e83-8. 
  21. Nho SJ, Freedman KB, Bansal SL, et al. The effect of radiofrequency energy on nonweight-bearing areas of bone following shoulder and knee arthroscopy. Orthopedics 2005;28:392-9. 
  22. Baumgarten KM, Altchek DW, Cordasco FA. Arthroscopically assisted acromioclavicular joint reconstruction. Arthroscopy 2006;22:228. 
  23. Katthagen JC, Anavian J, Tahal DS, Millett PJ. Arthroscopic remplissage and open latarjet procedure for the treatment of anterior glenohumeral instability with severe bipolar bone loss. Arthrosc Tech 2016;5:e1135-41. 
  24. Ganokroj P, Keyurapan E. Arthroscopic bony bankart repair using a double-row double-pulley technique. Arthrosc Tech 2018;8:e31-6. 
  25. Lewington MR, Urquhart N, Wong IH. Lateral decubitus all-arthroscopic Latarjet procedure for treatment of shoulder instability. Arthrosc Tech 2015;4:e207-13. 
  26. Gomes N, Hardy P, Bauer T. Arthroscopic treatment of chronic anterior instability of the shoulder in Marfan's syndrome. Arthroscopy 2007;23:110. 
  27. Shih CA, Chiang FL, Hong CK, et al. Arthroscopic transtendinous biceps tenodesis with all-suture anchor. Arthrosc Tech 2017;6:e705-9. 
  28. Daggett M, Stepanovich B, Meyers A, Geraghty B. Arthroscopic on-lay biceps tenodesis: the loop-lock technique. Arthrosc Tech 2019;8:e935-9. 
  29. Saithna A, Longo A, Leiter J, MacDonald P, Old J. Safety of the "inside-out" radiofrequency ablation technique for rapid localization of the biceps tendon in the subacromial space. Tech Shoulder Elbow Surg 2016;17:98-9. 
  30. Armangil M, Akan B, Basarir K, Bilgin SS, Gurcan S, Demirtas M. Arthroscopic release of the subscapularis for shoulder contracture of obstetric palsy. Eur J Orthop Surg Traumatol 2012;22:25-8. 
  31. Li X, Padmanabha A, Koh J, Cusano A. All-arthroscopic coracoclavicular ligament reconstruction surgical technique using a semitendinosus allograft and tenodesis screws. Arthrosc Tech 2017;6:e413-7. 
  32. Yalizis M, Kruse K 2nd, Godeneche A. Arthroscopic "panorama" view of the subacromial space via deltoid fascia release. Arthrosc Tech 2016;5:e935-9. 
  33. Pagan Conesa A, Verdu Aznar C, Herrera MR, Lopez-Prats FA. Arthroscopic marginal resection of a lipoma of the supraspinatus muscle in the subacromial space. Arthrosc Tech 2015;4:e371-4. 
  34. O'Brien SJ, Taylor SA, DiPietro JR, Newman AM, Drakos MC, Voos JE. The arthroscopic "subdeltoid approach" to the anterior shoulder. J Shoulder Elbow Surg 2013;22:e6-10. 
  35. Mellano CR, Virk MS, Shin JJ, Aiyash S, Romeo AA. Tips and technical pearls for performing an arthroscopic acromioplasty in a reproducible and accurate manner. Tech Shoulder Elbow Surg 2015;16:59-62. 
  36. Valenti P, Maroun C, Schoch B, Arango SO, Werthel JD. Arthroscopic Trillat coracoid transfer procedure using a cortical button for chronic anterior shoulder instability. Arthrosc Tech 2019;8:e199-204. 
  37. Hendrix ST, Hoyle M, Tokish JM. Arthroscopic pectoralis minor release. Arthrosc Tech 2018;7:e589-94. 
  38. Theopold J, Marquass B, von Dercks N, et al. Arthroscopically guided navigation for repair of acromioclavicular joint dislocations: a safe technique with reduced intraoperative radiation exposure. Patient Saf Surg 2015;9:41. 
  39. Scheibel M, Ifesanya A, Pauly S, Haas NP. Arthroscopically assisted coracoclavicular ligament reconstruction for chronic acromioclavicular joint instability. Arch Orthop Trauma Surg 2008;128:1327-33. 
  40. Almazan A, Sierra L, Cruz F, et al. Arthroscopic transarticular distal clavicle resection. Tech Shoulder Elbow Surg 2006;7:206-9. 
  41. Boileau P, McClelland WB Jr, O'Shea K, et al. Arthroscopic Hill-Sachs remplissage with Bankart repair: strategy and technique. JBJS Essent Surg Tech 2014;4:e4. 
  42. Rausch V, Konigshausen M, Schildhauer TA, Seybold D, Gessmann J. Arthroscopic lateral border resection in medialized scapula neck fractures. Arthrosc Tech 2017;6:e1619-23. 
  43. Bhatia DN, de Beer JF, van Rooyen KS, du Toit DF. Arthroscopic suprascapular nerve decompression at the suprascapular notch. Arthroscopy 2006;22:1009-13. 
  44. Park YB, Park YE, Koh KH, Lim TK, Shon MS, Yoo JC. Subscapularis tendon repair using suture bridge technique. Arthrosc Tech 2015;4:e133-7. 
  45. Shon MS, Koh KH, Lim TK, Lee SW, Park YE, Yoo JC. Arthroscopic suture anchor tenodesis: loop-suture technique. Arthrosc Tech 2013;2:e105-10. 
  46. Petri M, Greenspoon JA, Millett PJ. Arthroscopic superior capsule reconstruction for irreparable rotator cuff tears. Arthrosc Tech 2015;4:e751-5. 
  47. Laskovski J, Abrams J, Bogdanovska A, Taliwal N, Taylor M, Fisher M. Arthroscopic rotator cuff repair with allograft augmentation: making it simple. Arthrosc Tech 2019;8:e597-603. 
  48. Cabarcas BC, Garcia GH, Liu JN, Gowd AK, Romeo AA. Double-row arthroscopic subscapularis repair: a surgical technique. Arthrosc Tech 2018;7:e805-9. 
  49. Chernchujit B, Shahul Hamid MA, Aimprasittichai S. Knotless suture bridge technique in high-grade bursal-sided rotator cuff tears: is this the way forward. Arthrosc Tech 2017;6:e2259-63. 
  50. Warth RJ, Lee JT, Millett PJ. Figure-of-eight tendon graft reconstruction for sternoclavicular joint instability: biomechanical rationale, surgical technique, and a review of clinical outcomes. Oper Tech Sports Med 2014;22:260-8. 
  51. Yamakado K. Quantification of the learning curve for arthroscopic suprascapular nerve decompression: an evaluation of 300 cases. Arthroscopy 2015;31:191-6. 
  52. Faruque R, Matthews B, Bahho Z, et al. Comparison between 2 types of radiofrequency ablation systems in arthroscopic rotator cuff repair: a randomized controlled trial. Orthop J Sports Med 2019;7:2325967119835224. 
  53. Gereli A, Kocaoglu B, Guven O, Turkmen M. Warm irrigation fluid does not raise the subacromial temperature to harmful levels while using radiofrequency device. Int J Shoulder Surg 2015;9:99-100. 
  54. Chivot M, Airaudi S, Galland A, Gravier R. Analysis of parameters influencing intraarticular temperature during radiofrequency use in shoulder arthroscopy. Eur J Orthop Surg Traumatol 2019;29:1205-10. 
  55. Barker SL, Johnstone AJ, Kumar K. In vivo temperature measurement in the subacromial bursa during arthroscopic subacromial decompression. J Shoulder Elbow Surg 2012;21:804-7. 
  56. Davies H, Wynn-Jones H, De Smet T, Johnson P, Sampath S, Sjolin S. Fluid temperatures during arthroscopic subacromial decompression using a radiofrequency probe. Acta Orthop Belg 2009;75:153-7. 
  57. Zoric BB, Horn N, Braun S, Millett PJ. Factors influencing intra-articular fluid temperature profiles with radiofrequency ablation. J Bone Joint Surg Am 2009;91:2448-54. 
  58. Good CR, Shindle MK, Griffith MH, Wanich T, Warren RF. Effect of radiofrequency energy on glenohumeral fluid temperature during shoulder arthroscopy. J Bone Joint Surg Am 2009;91:429-34. 
  59. Edwards RB 3rd, Lu Y, Markel MD. The basic science of thermally assisted chondroplasty. Clin Sports Med 2002;21:619-47. 
  60. Valet S, Weisse B, Fischer B, Meyer DC. Mechanical effects of heat exposure from a bipolar radiofrequency probe on suture under simulated arthroscopic conditions. Arthroscopy 2016;32:1985-92. 
  61. Shah AA, Kang P, Deutsch A. Radiofrequency and its effect on suture strength. Orthopedics 2009;32:894. 
  62. Ficklscherer A, Serr M, Loitsch T, et al. The influence of different footprint preparation techniques on tissue regeneration in rotator cuff repair in an animal model. Arch Med Sci 2017;13:481-8. 
  63. Jerosch J, Aldawoudy AM. Chondrolysis of the glenohumeral joint following arthroscopic capsular release for adhesive capsulitis: a case report. Knee Surg Sports Traumatol Arthrosc 2007;15:292-4. 
  64. Bonsell S. Detached deltoid during arthroscopic subacromial decompression. Arthroscopy 2000;16:745-8. 
  65. Troxell CR, Morgan CD, Rajan S, Leitman EH, Bartolozzi AR. Dermal burns associated with bipolar radiofrequency ablation in the subacromial space. Arthroscopy 2011;27:142-4. 
  66. Chahar D, Chawla A, Verma N, Mittal A, Pankaj A. Dermal burn: an unusual complication of radio frequency probe in shoulder arthroscopy. J Arthrosc Joint Surg 2017;4:38-40. 
  67. Talati RK, Dein EJ, Huri G, McFarland EG. Cutaneous burn caused by radiofrequency ablation probe during shoulder arthroscopy. Am J Orthop (Belle Mead NJ) 2015;44:E58-60. 
  68. Kouk SN, Zoric B, Stetson WB. Complication of the use of a radiofrequency device in arthroscopic shoulder surgery: second-degree burn of the shoulder girdle. Arthroscopy 2011;27:136-41. 
  69. Jang JS, Choi HJ, Kang SH, Yang JS, Lee JJ, Hwang SM. Effect of pulsed radiofrequency neuromodulation on clinical improvements in the patients of chronic intractable shoulder pain. J Korean Neurosurg Soc 2013;54:507-10. 
  70. Yasura K, Nakagawa Y, Kobayashi M, Kuroki H, Nakamura T. Mechanical and biochemical effect of monopolar radiofrequency energy on human articular cartilage: an in vitro study. Am J Sports Med 2006;34:1322-7. 
  71. Taverna E, Battistella F, Sansone V, Perfetti C, Tasto JP. Radiofrequency-based plasma microtenotomy compared with arthroscopic subacromial decompression yields equivalent outcomes for rotator cuff tendinosis. Arthroscopy 2007;23:1042-51. 
  72. Diab MA, Fernandez GN, Elsorafy K. Time and cost savings in arthroscopic subacromial decompression: the use of bipolar versus monopolar radiofrequency. Int Orthop 2009;33:175-9.