• Title/Summary/Keyword: Buoyance

Search Result 48, Processing Time 0.023 seconds

A numerical study on effects of thermal buoyance force on number of jet fans for smoke control (도로터널 화재시 열부력이 제연용 제트팬 댓수에 미치는 영향에 대한 해석적 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.301-310
    • /
    • 2013
  • Jet fans are installed in road tunnels in order to maintain critical velocity when fire occurs. Generally the number of jet fans against fire are calculated by considering critical velocity and flow resistance by wall friction, vehicle drag force, thermal buoyance force and natural wind. In domestic case, thermal buoyance force is not considered in estimating the number of jet fans. So, in this study, we investigated the pressure loss due to the thermal buoyance force induced by tunnel air temperature rise and the impact of thermal buoyance force on the number of jet fans by the numerical fire simulation for the tunnel length(500, 750, 1000, 1500, 2000, 3500m) and grade (-1.0, -1.5, -2.0%). Considering the thermal buoyance force, number of jet fans have to be increased. Especially in the case of 100MW of heat release rate, the pressure loss due to thermal buoyance force exceed the maximum pressure loss due to vehicle drag resistance, so it is analyzed that number of 2~11 jet fans are needed additionally than current design criteria. Thus, in case of estimating the number of jet fans, it must be considered of thermal buoyance force induced tunnel air temperature rise by fire.

Lateral Load Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력앵커의 수평재하시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.165-174
    • /
    • 2004
  • This study is about a horizontal load test of buoyance anchor installed in the section where underground water level happens in the depth of 5m under the ground when the ground is excavated, because the section as a excavation section of high speed railway ${\bigcirc}{\bigcirc}$ station is near a rivers and because the section always has a reservoir of full water level on the left. Therefore, in this study we will appraise the long-term stability of the structure permanently being taken buoyance by the underground water level, through the spot test of the buoyance anchor installed in the section where underground water level happens. For that, Bar Type anchor is used, which can get enough pulling-out force by a method to resist buoyance by using friction force against the ground by high strength steel rod or steel wire. Anti-buoyance anchor is installed on the bottom slab of underground structure being taken horizontal force by the braking and accelerating of high speed train. And, It is aimed to analyze and grasp the review result of stability for the horizontal force that happens at the parking and stopping of high speed train, by executing horizontal load test for the grasping of the movements characteristic of buoyance anchor.

Tension Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력저항 앵커의 인장 시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.175-181
    • /
    • 2004
  • This study is about a section where underground water level occurs at the underground 5m depth by the excavation of the ground, as a stream is adjacent to a excavation section of High Speed Railway ${\bigcirc}{\bigcirc}$ Station construction sections and a reservoir being always full of water is located at the left side of the construction section. Therefore this test is executed for the design and construction of buoyance anchors able to permanently prevent buoyance by the underground water level at working and for the stable construction and permanent smooth maintenance of structures. In this test, bar type anchors are divided according to their length and standard to execute test-anchor test, and In spot test, 9 test-anchors test, proof test to construction process, suitability test and acceptance test are executed 4 times to 9 test-anchors by dividing anchors according to the length of permanent anchor, the outer diameter of bar and boring diameter. Standard motion characteristic centering on load transmission and break mechanism of bar-type anchors for the prevention of buoyance will be showed in the thesis.

Review of Recovery Efficiency for Modified Free-fall Grab (자유낙하식 시료채취기(free-fall grab)의 개량에 따른 회수율 향상 검토)

  • Lee, Gun-Chang;Chi, Sang-Bum;Park, Cheong-Kee;Yoo, Chan-Min;Ko, Young-Tak;Ham, Dong-Jin
    • Ocean and Polar Research
    • /
    • v.26 no.2
    • /
    • pp.361-365
    • /
    • 2004
  • Deep-sea Resources Research Center (DRRC) has been using a free-fall grab (FFG) for the resource evaluation of polymetallic nodules in the KODOS (Korea Deep Ocean Study) area, NE Pacific, since 1992. A FFG model (Model 4200, Benthos) adapting one glass buoy system (diameter 17 inch, net buoyance 25.4 kg) has been used until 1993. Since then, DRRC has carried out a study to increase the recovery rate of FFG and it was found that a revised system adapting an additional buoy (diameter 10 inch, net buoyance 4.5 kg) gives improved results. The nodule sampling tests were performed using two different models for the same study area and the resulting recovery rates were compared. The result shows no distinct difference in recovery time between two models, but average recovery rate of the revised model was increased to 99.44% from 96.06% of the original model.

Design of $H_{\infty}$ Controller for Underwater Vehicle and Nonlinear Simulation (수중운동체에 대한 $H_{\infty}$ 제어기 설계와 비선형 시뮬레이션)

  • 전찬식;김종해박홍배
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.215-218
    • /
    • 1998
  • In this paper, we design the $H_{\infty}$ controllers satisfying robust stability and performance for underwater vehicle. The underwater vehicle has computations delay time and input delay. In addition, there exist parameter uncertainties by the roll motion coefficient error, buoyance error, and gravity error. We design the $H_{\infty}$ controllers using model-matching method and check the performance of the proposed controller by nonlinear simulation which includes time delay model, sensor error model, and actuator model.

  • PDF

An experiment on activation energies of alcohol fuels (알코홀 연료의 활성화 에너지에 관한 실험적 연구)

  • 이정헌;김경오;정석호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.43-48
    • /
    • 1991
  • Activation energies of alcohol fuels have been determined through droplet combustion and extinction experiments using droplet suspension technique in a low pressure environment to minimize the effect of buoyance. Results show that the activation energies determined are 41.4 kcal/mol for ethanol, 47.6 for 1-propanol, 48.4 for 1-butanol, 40.0 for 2-butanol, 48.0 for 1- pentanol, 50.8 for 1-hexanol and 51.7 for 1-decanol.

  • PDF

Numerical Simulation of the Evolution and Structure of a Single Vortex in Reacting and Non-reacting Jet Flow Fields (반응 및 비반응 제트 유동장에서 단일 와동의 전개 및 구조에 대한 수치모사)

  • Hwang, Chul-Hong;Oh, Chang-Bo;Lee, Chang-Eon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.28-37
    • /
    • 2004
  • A two-dimensional direct numerical simulation was performed to investigate the evolution and vortical structure of a single vortex in reacting and non-reacting jet flow fields. A predictor-corrector-type numerical scheme with a low Mach number approximation was used, and a two-step global reaction mechanism was adopted as the combustion model. Through the comparisons of single vortex behaviors in reacting and non-reacting jet flow fields, it was found that the evolution characteristics and vortical structure of the single vortex were significantly influenced by a outer vortex that was generated from the buoyance effect as well as the chemical heat release. Furthermore, it was also identified that the differences of the vortical structure in reacting and non-reacting jet flow fields were mainly attributed to the thermal expansion, Baroclinic torque and buoyance effect.

Development of static and dynamic stability utilizing superior SUPER concrete 100MPa pontoon (정적 및 동적안전성이 우수한 SUPER concrete 100MPa 활용 부잔교 개발)

  • Lim, Hyoung Joo;Yun, Sik Jae;Lee, Sang Hee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.135-136
    • /
    • 2016
  • SUPER concrete poontoon is developed to overcome shortcomings about corrosion problem of steel pontoon and the insufficient freeboard line of concrete pontoon. Top slab of Pontoon resists truck load or sidewalk live load. The soffit slab and outer wall of Pontoon resist the horizontal and vertical components of wave pressure, and those were loaded along X and Y-axis of Pontoon. Global analysis for the Pontoon is carried out to design its cross-sections economically using a geometric non-linear time history analysis method by Strand7 and buoyance-stability calculated automatically on non-vertical boundary conditions. And the load-capacity of Pontoon is confirmed through mock-up tests.

  • PDF

A Study on the Buoy type Oil Guiding System for the Active Circulation type Oil Recovery Vessel (자연순환식 유회수선박에서의 부유식 기름유도장치에 관한 연구)

  • 이귀주;김경화
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.185-189
    • /
    • 2001
  • A study on the new active circulation type oil-water separation system including buoyancy type guidance system was carried out in this paper. Oil-water separation system is composed of several oil separation steps. Buoy type oil guiding system was developed based on the difference of buoyance of water and oil. The design speed of this vessel is 25 knots.

  • PDF

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF