• 제목/요약/키워드: Building vibration

검색결과 1,132건 처리시간 0.036초

Development of wind tunnel test model of mid-rise base-isolated building

  • Ohkuma, Takeshi;Yasui, Hachinori;Marukawa, Hisao
    • Wind and Structures
    • /
    • 제7권3호
    • /
    • pp.203-214
    • /
    • 2004
  • This paper describes a method for developing a multi-degree-of freedom aero-elasto-plastic model of a base-isolated mid-rise building. The horizontal stiffness of isolators is modeled by several tension springs and the vertical support is performed by air pressure from a compressor. A lead damper and a steel damper are modeled by a U-shaped lead line and an aluminum line. With this model, the frequency ratio of torsional vibration to sway vibration, and plastic displacements of isolation materials can be changed easily when needed. The results of isolation material tests and free vibration tests show that this model provides the object performance. The peak displacement factors are about 4.5 regardless of wind speed in wind tunnel tests, but their gust response factor decreases with increment of wind speed.

Updating of FE models of an instrumented G+9 RC building using measured data from strong motion and ambient vibration survey

  • Singh, J.P.;Agarwal, Pankaj;Kumar, Ashok;Thakkar, S.K.
    • Earthquakes and Structures
    • /
    • 제4권3호
    • /
    • pp.325-339
    • /
    • 2013
  • A number of structural and modal parameters are derived from the strong motion records of an instrumented G + 9 storeyed RC building during Bhuj earthquake, 26 Jan. 2001 in India. Some of the extracted parameters are peak floor accelerations, storey drift and modal characteristics. Modal parameters of the building are also compared with the values obtained from ambient vibration survey of the instrumented building after the occurrence of earthquake. These parameters are further used for calibrating the accuracy of fixed-base Finite Element (FE) models considering structural and non-structural elements. Some conclusions are drawn based on theoretical and experimental results obtained from strong motion records and time history analysis of FE models. An important outcome of the study is that strong motion peak acceleration profile in two horizontal directions is close to FE model in which masonry infill walls are modeled.

신경회로망 예측 제어기를 이용한 건축 구조물의 진동제어 (A Vibration Control of Building Structure using Neural Network Predictive Controller)

  • 조현철;이영진;강석봉;이권순
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.434-443
    • /
    • 1999
  • In this paper, neural network predictive PID (NNPPID) control system is proposed to reduce the vibration of building structure. NNPPID control system is made up predictor, controller, and self-tuner to yield the parameters of controller. The neural networks predictor forecasts the future output based on present input and output of building structure. The controller is PID type whose parameters are yielded by neural networks self-tuning algorithm. Computer simulations show displacements of single and multi-story structure applied to NNPPID system about disturbance loads-wind forces and earthquakes.

  • PDF

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

능동 제어장치를 이용한 건물의 진동제어 (I): 시스템 설계 (Vibration Control for Building Structures usign Active Mass Driver(I) : System Design)

  • 민경원;김두훈;이성경;황재승
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.87-94
    • /
    • 1998
  • 현대의 고층건물들은 점차 유연해지고 경량화 됨으로 인하여 지진이나 바람과 같은 하중에 대하여 취약하다. 그러므로 이러한 하중에 대한 진동수준을 감소시키기 위하여 진동제어 시스템의 성능을 더욱 향상시킬 필요가 있으며 능동제어장치를 이용한 방법이 요구되고 있다 따라서 본 논문에서는 소형 진동대, 건물모델, 건물모델의 응답을 측정하는 센서, 신호처리 보드 그리고, 능동 질량 추진기로 구성된 능동 진동제어 시스템을 구축하였으며 이러한 개별 시스템들의 동적 특성을 실험적인 방법으로 조사하였다 또한 건물모델에 El Centro 지진을 가하여 능동 진동제어 시스템의 성능을 검증하였다,.

  • PDF

Ambient and forced vibration testing with numerical identification for RC buildings

  • Aras, Fuat
    • Earthquakes and Structures
    • /
    • 제11권5호
    • /
    • pp.809-822
    • /
    • 2016
  • Reinforced concrete buildings constitute the majority of the building stock of Turkey and much of them, do not comply the earthquake codes. Recently there is a great tendency for strengthening to heal their earthquake performance. The performance evaluations are usually executed by the numerical investigations performed in computer packages. However, the numerical models are often far from representing the real behaviour of the existing buildings. In this condition, experimental modal analysis fills a gap to correct the numerical models to be used in further analysis. On the other hand, there have been a few dynamic tests performed on the existing reinforced concrete buildings. Especially forced vibration survey is not preferred due to the inherent difficulties, high cost and probable risk of damage. This study applies both ambient and forced vibration surveys to investigate the dynamic properties of a six-story residential building in Istanbul. Mode shapes, modal frequencies and damping ration were determined. Later on numerical analysis with finite element method was performed. Based on the first three modes of the building, a model updating strategy was employed. The study enabled to compare the results of ambient and forced vibration surveys and check the accuracy of the numerical models used for the performance evaluation of the reinforced concrete buildings.

지하철 진동에 의한 건축구조물의 진동특성 (Dynamic Response of Building Structures Induced by Subway Operation)

  • 김희철;이동근;민경원
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.95-106
    • /
    • 1995
  • 지하철의 운행에 의한 소음과 진동은 운행로 주위의 주민을 괴롭히는 중요한 요소의 하나이다. 일반적인 건물의 진동은 횡방향의 진동을 많이 고려하고 있으나 지하철의 운행에 의한 건물의 진동은 수직방향의 진동을 주요하게 다루어야 한다. 수직방향의 진동을 고려하기 위한 구조물은 보의 진동이 고려된 모델이어야 한다. 따라서 구조물의 수평방향 진동을 고려하기 위하여 사용된 모델은 수직방향의 진동을 고려하기 위한 모델과 같이 사용될 수 없다. 건물의 수직진동을 고려한 해석을 수행하기 위해서는 보의 관성력을 충분히 고려할 수 있는 모델이 사용되어야 한다. 본 논문에서는 지하철의 운행에 의한 구조물의 수직방향진동을 고려하기 위한 구조물의 해석 모델기법에 대하여 연구한 결과 기둥의 경우 하나이상 보의 경우 두개 이상의 요소로 나누어 해석하는 것이 바람직한 것으로 나타났다.

  • PDF

ISO/TC 43/SC 2(건축음향)에 대하여 (Overview of the ISO/TC 43/SC 2(Building Acoustics))

  • 장길수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.699-703
    • /
    • 1998
  • ISO/TC 43/SC 2(Building Acoustics)은 음향기술위원회의 건축음향분과로서 건축음향관련 규격을 제정하거나 개정하고 관련규격을 검토하는 운영위원회이다. ISO/TC 43/SC 2의 운영범위와 최근의 활동상황을 개괄적으로 소개하고자 한다.

  • PDF

Rehabilitation of heavily earthquake damaged masonry building using steel straps

  • Altin, Sinan;Kuran, Fikret;Anil, Ozgur;Kara, M. Emin
    • Structural Engineering and Mechanics
    • /
    • 제30권6호
    • /
    • pp.651-664
    • /
    • 2008
  • The purpose of this study is to develop a rehabilitation technique for heavily earthquake damaged masonry buildings. A full scale one storey masonry building with window and door openings was manufactured and tested on the shock table by applying increased amplitude free vibration up to the point where heavy earthquake damage was observed. Damaged test building was rehabilitated with vertical and diagonal steel straps and then tested again. The effectiveness of improvements obtained by the rehabilitation technique was investigated. Steel straps improved the lateral strength and stiffness of masonry walls and limited the lateral displacement of building. Stability of the masonry walls were also improved by the steel straps. Steel straps reduced the natural period of the earthquake damaged masonry building and prevented the failure of the building at the same amplitude of free vibration.