• 제목/요약/키워드: Building energy simulation program

검색결과 143건 처리시간 0.025초

공조설비의 필터차압 변화에 따른 에너지 소비성능 평가 (Evaluation of Energy Consumption of HVAC System for Air Filter Pressure Difference Change in Commercial Buildings)

  • 원근호;곽노열;허정호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1227-1233
    • /
    • 2004
  • Air handling unit (AHU)'s air filter pressure difference is important for energy consumption and indoor air quality. Both energy Performance data and air filter differential pressure of AHU in real office buildings were monitored and analyzed to investigate quantitatively energy impact as dust buildup level on air filter grows. We also modeled and simulated CAV system using HVACSIM+ program to examine the energy effect of dust buildup on filters. Through analysis of time series pressure drop data, the filter pressure difference rate has been increased due to cumulative supply air flow rate increase. As filter pressure drop increased to 1 inch water column, it is found that the supply air flow rate was decreased by 10%, the chilled water flow rate was increased by 5.9% and the pump energy consumption was increased to 5.9%.

창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석 (Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung)

  • 김민휘;김진효;권오현;한욱;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

빙축열을 이용한 대형빌딩 공기조화시스템 개발과 설계전산화에 관한 연구 (A Study on the Development of the Large Building Air-conditioning System with the Regenerative Ice-energy and its Computer Aided Design)

  • 권형정;김원영;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권5호
    • /
    • pp.38-46
    • /
    • 1991
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air-conditioning systems are being operated during daytime in summer season. Therefore, it is necessary to construct an additional electric power plant and to develop the new air-conditioning system for relieving the peak load. This paper analysed the performance characteristics of this experimental regenerative ice energy system by means of a bundle of the heat-pipes. And the result of this analysis was applied to the simulation of an air-conditioning system model. Also, an operation program of moisture air was made according to air load and in order to computerize the air-conditioning system a CAD program was developed by the properties of moisture air.

  • PDF

Prototype Development for BIM based Thermal Insulation and Condensation Performance Evaluation of Apartment Housings

  • Oh, Hyangok;Cho, Daegu;Jang, Hyang-In;Hong, Soungwook;Lee, Myung Sik
    • Architectural research
    • /
    • 제17권2호
    • /
    • pp.75-81
    • /
    • 2015
  • Insulation and condensation performance evaluation (I&CPE) is an important energy analysis. While considerable amount of data are already represented in a Building Information Model (BIM), the lack of interoperability between BIM modeling and I&CPE programs prevents the simulation process from being efficient and accurate. This study proposes a prototype of a BIM-based I&CPE simulation program, in order to enhance the interoperability between BIM modeling and I&CPE programs. This study discusses the information flow process, defines the required information and its level of detail, develops standardized libraries, and finally proposes a prototype that consists of a data extraction module, conversion module, and performance module. The assurance of interoperability between systems might greatly benefit architects and energy professionals.

건물냉방시스템에 해양심층수 적용의 경제성 분석 (Economic Feasibility Assessment of a Deep Sea Water District Cooling System)

  • 김삼열;조수
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.14-21
    • /
    • 2009
  • Recently, alternative energy resources have emerged considerably due to the high oil prices and environment problems. Deep sea water that is one of the natural energy sources can be one of the attractive solutions to reduce the environment problems, and there are already a few examples in some developed countries. In this study, cooling system of deep sea water using heat exchangers of two hotels, located in near Haeundae Bay in Busan, have been analyzed on the quantity of electricity and gas use comparison between existing cooling system and deep seawater cooling system by using E-Quest simulation program. The results of the study showed that the Hotel A approximately saves 370 millions won per year, and the Hotel B saves 248 millions won per year. It means that the cooling system by using deep sea water has great worth to reduce the ratio of fuel sources.

단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능 (Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards)

  • 김세종;박주생
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.876-883
    • /
    • 2015
  • 국립산림과학원에서는 한옥의 전통건축기술을 바탕으로 한국형 기둥-보 목조주택인 ?그린 프로젝트를 2006년부터 진행해오고 있다. 최근에는 에너지 절약 기술요소를 적용하여 건물의 에너지성능을 개선하고자 하였다. 본 연구에서는 강화된 단열기준에 따른 기둥-보 목조벽체의 단열상세를 제시하고 그에 따른 건물 에너지 절감 효과를 평가하고자 하였다. 건물외피의 열관류율은 현행법 수준과 저에너지주택인 패시브하우스 수준인 두 단계로 나누었으며 건물에너지 성능을 평가하기 위하여 건물의 기밀성능은 국내 신축 목조주택 수준인 $3.0h^{-1}$과 패시브하우스 수준이 $0.6h^{-1}$ 두 단계로 나누어 열관류율과 기밀성능의 조합에 따라 4가지 경우에 대한 건물에너지 성능 평가가 이루어졌다. 대상건물은 서울에 위치하였으며 에너지 성능은 상용 건물에너지성능 평가 프로그램인 CE3가 사용되었다. 강화된 열관류율에 따라 시뮬레이션을 진행한 결과 연간 난방에너지 요구량은 $14kWh/(m^2{\cdot}a)$ 절감효과를 나타냈다.

통합 채광시스템의 건물 냉난방 에너지 성능평가 (Building Energy Savings due to Incorporated Daylight-Glazing Systems)

  • 김정태;안현태;김곤
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2005
  • 건물 내에 존재하는 자연광은 조명원으로 국한되지 않고 시각적, 심리적 자극을 통한 실내 환경의 질적 향상에 이르기까지 에너지절약 및 공간의 쾌적성에 큰 영향을 미친다. 유입되는 자연광량에 비례적으로 연동되는 건물에너지는 전기조명에너지를 절감시키고 난방 기간동안 일사열의 유입에 따른 난방에너지를 절감시킨다. 여름철에는 전기조명의 소등으로 인한 조명원의 발열량이 감소됨으로써 냉방부하의 감소에 이르기까지 포괄적인 영향을 미친다. 조명개발분야의 선진국에서는 에너지 절약형 광원의 대체와 아울러 자연채광과 통합된 최적 조명제어 기술의 운용만이 건물이 가지고 있는 에너지 절약의 잠재력을 현실화시킬 수 있다고 판단하고 있다. 따라서 본 연구는 일반적인 사무소 모델 공간의 에너지 절약형 인공조명을 대상으로 자연광 유입에 따른 연동적 조명제어 기법을 적용하는 경우를 대상으로, 인공조명의 소등량에 따른 조명에너지의 절감량과 이에 수반되는 냉방에너지의 점감량 및 일사열 취즉에 따른 겨울철 난방 부하 절감량을 분석함으로써 자연채광의 건물에너지에 대한 연간 기여도를 통합 분석하였다. 특히 자연채광의 성능은 실험을 통한 측정 데이터를 이용하고 에너지 해석 프로그램을 재구성하여 실질적인 절감량을 도출하도록 시도하였다.

고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구 (A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State)

  • 김진호;양정훈;석호태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구 (Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds)

  • 조원화;임남기
    • 한국건축시공학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 2010
  • 본 연구에서는 전열해석 프로그램인 피지벨(PHYSIBEL)을 사용하여 블라인드 내장형 창호시스템의 일사차단성능 및 단열성능에 따른 에너지 성능을 평가하였다. 피지벨 해석시 창호별 구성 재료의 열적특성과 해석조건을 결정하기 위해서 Mock-up시험을 실시하였으며, 컴퓨터 시뮬레이션을 통한 결과를 바탕으로 공동주택 기준층 1개 세대(33평형)를 대상으로 연간에너지 소비특성, 연간전열량, 연간 냉난방 비용을 분석하였다. 실험결과, 연간전열량은 일반 창호시스템 대비 블라인드 내장형 창호시스템에서 블라인드를 올린 경우 냉방시 10%, 난방시 11% 절감할 수 있으며, 블라인드를 내린 경우 냉방시 25%, 난방시 30%정도를 절감할 수 있는 것으로 나타났다. 블라인드 내장형 창호시스템의 냉 난방 부하 절감량은 일반 창호시스템에 비해 냉방시 283.3KWh, 난방시 76.3KWh 로 냉 난방 에너지 절감효과는 단위세대당 359.6KWh 절감시킬 수 있는 것으로 나타났으며, 이것은 단위세대당 연간 에너지원단위(TOE) 약 0.078toe, 이산화탄소톤($tCO_2$) $0.16tCO_2$을 절감시킬 수 있어 온실가스 저감에도 유리할 것으로 판단된다. 또한, 블라인드 내장형 창호시스템의 냉 난방비용 절감액은 일반창호시스템과 비교하여 연간 냉방비용 10만원, 난방비용 5만원으로 연간 냉 난방 비용을 약 15만원 정도 절감시킬 수 있는 것으로 나타났다.