• 제목/요약/키워드: Building damages

검색결과 352건 처리시간 0.029초

나노와이어를 이용한 바이오 소자 응용기술 (Nanowires for bio-device)

  • 최헌진;박정민
    • 진공이야기
    • /
    • 제3권3호
    • /
    • pp.4-9
    • /
    • 2016
  • Nanowires have excellent properties such as high crystallinity, good mechanical properties, quantum confinement effect and high chemical activity, and thus are promising building blocks for many applications. Here we firstly review the fabrication of nanowires by top-down and bottom-up process. We then review nanowires as building blocks for bio applications including bio sensing, cell signaling and cell stimulating. It shows that nanowires are promising for the development of advanced bio technologies that can address ultrahigh sensitivity, and long term cell signaling and stimulating without cell damages.

목조문화재의 원형보존을 위한 충해 방제방안 (Pest control managements for preservation of wooden cultural properties)

  • 이규식;정소영;정용재
    • 보존과학연구
    • /
    • 통권21호
    • /
    • pp.5-55
    • /
    • 2000
  • The cultural properties are damaged by various causes according to the characteristics of material, the condition of preservation, and the period of time. Especially, biodeterioration makes lots of damages in organic properties than inorganic ones. The damages of wooden cultural properties by insects usually are caused by the three orders; Isoptera, Coleoptera, and Hymenoptera. As the result of investigation on the state of 141 buildings of wooden cultural properties in 1999, some of them were damaged by many kinds off actors; wasp, powder post beetle, cigarette beetle, termite, decay, and physical cracking. And it was found that the patterns of damages were related to species-specific habits of insects. There are several methods of pest control for the prevention of wooden cultural properties from damages caused by insects. Those are as follows; physical control, chemical control, biological control, and integrated pest management. When insects and fungi were detected at the wooden buildings, the fumigation is best treatment to stop biodeterioration. And then, wood materials also need to be treated with insecticidal and antiseptic chemicals to avoid a reinfestation, because the fumigant is volatile. The six commercial chemicals which are applied to the insecticidal and antiseptic treatment of wooden cultural properties were purchased to test their abilities. According to the comparative results of efficacy of them in laboratory, chemical D showed excellent efficacy in all items, including antiseptic and termiticidal items. The goal of these pest controls is to protect wooden buildings from insects and microorganisms. The most effective method used currently is chemical control(fumigation, insecticidal and anticeptic chemical treatment), but it has to be treated periodically to control pest effectively. Recently environmentally-friendly control methods such as bait system or biological treatments are replacing traditional barrier treatments using large amounts of chemicals. Especially, termite is a social insect which makes a colony. Although a building with fumigation treatment is safe for a while, once attacked building has a risk of damage by reinfestation of termite. Therefore, to control termites from damaged building, the entire colony including reproductives(queen and king) and larvae around buildings must beeliminated. Bait system can be used as a preventive measure in early detection of them through termites colony monitoring and baiting. It would be the most effective for termite control if bait system would be used together with the chemical controls.

  • PDF

준능동 MR 댐퍼가 설치된 건축 구조물의 분산제어 (Decentralized Control of Building Structures Installed with Semi-active MR Damper)

  • 윤경조;이상현;민경원;이성경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.127-132
    • /
    • 2007
  • In this paper, to overcome local damages of structures, an uncertainty of structural model, installing sensors of structures, and economics of building system, decentralized semi-active magnetorheological(MR) damper using the displacement or velocity transferred to the response of floor installed damper is proposed. Relative magnitude between the control force of dampers and the story shear force is difined as design variables and the performance indices response spectra analysis through nonlinear time history analysis excited by seismic loads is performed according to this design variables. And the performance of this decentralized MR damper is compared with previous centralized LQR control algorithm using 3-stories benchmark building structure excited by El Centro (1940, N.S) in order to evaluate the application of building structures.

  • PDF

빌딩피해에 대한 GIS 손상평가 및 지진 후 평가 (GIS-based Loss Estimation and Post-earthquake Assessment of Building Damage)

  • 전상수
    • 한국지반공학회논문집
    • /
    • 제20권7호
    • /
    • pp.15-24
    • /
    • 2004
  • 본 논문은 1994 Northridge 지진에 의해 발생된 주거건물손상에 관하여 건물 교체시의 가격에 대한 상대적 수리비용의 개념으로 GIS기반의 손상평가에 관하여 기술하였다. 빌딩손상은 164개의 서로 다른 지역에서 얻어진 지진기록으로부터 유도된 지진매개변수와 빌딩위치 및 안전조사보고서를 바탕으로 평가하였다. 본 논문은 가장 심한 건물피해를 받은 위치를 규명하는 인식 알고리즘이 GIS를 통하여 개발되었다. 이러한 알고리즘은 지진 후 신속한 응급조치와 위성으로부터 얻어진 데이터를 짧은 시간에 분석할 수 있는 프레임을 제공한다.

EPIQR+를 이용한 구청사 건물에 대한 경제적, 에너지관점에서의 건물 재평가 (A Study on Process for District Office Building Maintenance with EPIQR+ (on Focusing Energy and Economics Evaluation))

  • 김태한
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.13-20
    • /
    • 2009
  • This study suggested practical application of decision aid tool on re-evaluation of current buildings with a focus on a energy and economics evaluation methodology. In Europe, over forty percent of all construction activities are for retrofit. For efficient construction, various tools for re-evaluating existing buildings have been developed and are in use. Legislations of relevant laws and studies are actively initiated. In particular, EPIQR (Energy Performance Indoor environment Quality Retrofit), which was developed through the EU's Third and Fourth Framework Programs laid a foundation on a new concept-based decision aid tool for re-evaluation of existing buildings. As for actual applications, based on this, EPIQR+ was developed to be in line with a building maintenance guideline (SIA 469) and is actively applied to public buildings. This tool quantifies the degree of damages of existing buildings and suggests alternatives to users in energy (SIA 380/1) and economical perspectives. This study examined these preceding tools and suggested some trenchant approaching for more comprehensive and efficient use of re-evaluation tools in building maintenance.

On the Chinese Code on fire safety design of steel building structures

  • Li, G.Q.;Guo, S.X.;Jiang, S.C.
    • Steel and Composite Structures
    • /
    • 제5권5호
    • /
    • pp.395-405
    • /
    • 2005
  • This work introduces to the international scientific community the Chinese Code on fire safety design of steel building structures. The aim of the Code is to prevent the structure of a steel building subjected to fire from collapsing, ensure safe evacuation of building occupants, and reduce the cost for repairing the damages of the structure caused by fire. The main contents of the Code is presented in this paper, including the fire duration requirements of structural components, fundamental requirements on fire safety design of steel components, temperature increasing of atmosphere and components in fire, loading effect and capacity of various components in fire, and procedure for fire-resistant design of steel components. The analytical approach is employed in the Code and the effectiveness of the Code is validated through experiments.

A DEVELOPMENT OF MODEL FOR FIRE HAZARD ASSESSMENTS H THE BUILDINGS

  • Lee, Su-Kyung;Kim, Su-Tae;Ha, Dong-Myung
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.384-391
    • /
    • 1997
  • The hazard assessment in which the potential hazard factors In the buildings are investigated and the scale of the hazard is analyzed should be performed first in order to prevent personal and material damages due to building fire. In this study, the building fire hazard are assessed using 822-item checklist, for the qualitative evaluation of which the main factors are classified into 10 items, yielding 100 scale points with some weighting. It is shown that present model is applicable for the assessment of all general buildings through the examination of the suitability of assessment model by actual assessment of existing building. Also, the checklist is prepared in itemized questionnaire form for easy assessment of building fire hazard. Therefore, the present model will be helpful for those working in fire prevention, who are suffering from the lack of manifest evaluation model for the fire prevention assessment so far in Korea.

  • PDF

Monitoring of wind effects on an instrumented low-rise building during severe tropical storm

  • Li, Q.S.;Hu, S.Y.
    • Wind and Structures
    • /
    • 제20권3호
    • /
    • pp.469-488
    • /
    • 2015
  • A full-scale instrumented low-rise building with gable roof was built at a coastal site with a high incidence of tropical cyclones for monitoring of wind effects on the building during windstorms. This paper presents the field measurements of the wind velocity field around and the wind-induced pressures on the low-rise building during the passage of severe tropical storm Soudelor. Near-ground wind characteristics such as wind speed, wind direction, turbulence intensity, gust factor, turbulence integral length scale and wind velocity spectra were investigated. The wind-induced pressures on the roof of the building were analyzed and discussed. The results revealed that the eave and ridge edges on the roof were subjected to the most severe suction pressures under quartering winds. These suction pressures showed obvious non-Gaussian behavior. The measured results were compared with the provisions of ASCE 7-10 to assess the suitability of the code of practice for the wind-resistant design of low-rise buildings under tropical cyclones. The field study aims to provide useful information that can enhance our understanding of the extreme wind effects on low-rise buildings in an effort to reduce tropical cyclone wind damages to residential buildings.

정적변위센서와 무선주파수를 이용한 기능성 건축부재에 관한 연구 (An Experimental Study on Functional Building Elements using Static Displacement Sensors and Radio Frequency)

  • 김동현;석창목;김태곤
    • 한국공간구조학회논문집
    • /
    • 제12권3호
    • /
    • pp.79-87
    • /
    • 2012
  • 본 연구에서 리드스위치를 이용한 정적변위센서를 무근과 철근 콘크리트 보에 부착하고 균열손상의 모니터링을 위해 무선주파수를 이용하였다. 무근 콘크리트 보와 철근 콘크리트 보에 외력이 작용하면 균열손상이 발생하고 균열의 증진으로 정적변위센서가 파괴되면 이와 연결되어 있는 무선주파수 발신자가 손상신호를 외부로 발신하게 된다. 이러한 기능성 건축부재에 대한 연구는 이상 기후 현상과 지진 등으로부터 건축물이나 주요구조물을 보호하는데 중요한 역할을 담당할 것으로 사료된다.

연속 지진에 의하여 손상된 필로티 RC 건축물의 BRB 보강 전/후의 취약성 평가 (Fragility Assessment of Damaged Piloti-Type RC Building With/Without BRB Under Successive Earthquakes)

  • 신지욱;김준희;이기학
    • 한국지진공학회논문집
    • /
    • 제17권3호
    • /
    • pp.133-141
    • /
    • 2013
  • This paper presents the seismic evaluation and prediction of a damaged piloti-type Reinforced Concrete (RC) building before and after post-retrofitting under successive earthquakes. For considering realistic successive earthquakes, the past records measured at the same station were combined. In this study, the damaged RC building due to the first earthquake was retrofitted with a buckling-restrained brace (BRB) before the second earthquake occurred. Nonlinear Time History Analysis (NTHA) was performed under the scaled intensity of the successive ground motions. Based on the extensive structural response data obtained form from the NTHA, the fragility relationships between the ground shaking intensity and the probability of reaching a pre-determined limit state was were derived. In addition, The the fragility curves of the pre-damaged building without and with the BRBs were employed to evaluate the effect of the successive earthquakes and the post-retrofit effect. Through the seismic assessment subjected to the successive records, it was observed that the seismic performance of the pre-damaged building was significantly affected by the severity of the damage from the first earthquake damages and the hysteresis behavior of the retrofit element.