• Title/Summary/Keyword: Building Wall

Search Result 1,770, Processing Time 0.028 seconds

A Study on Facades of Buildings - The window area ratio distribution of building facade in Tokyo - (건물파사드에 관한 실측조사 연구 - 일본 동경지역의 벽체의 창면적비를 중심으로 -)

  • Kim, Chong-Min;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.71-80
    • /
    • 2003
  • The purpose of this study is to analyze the window area ratio distribution of building facade in Tokyo metropolitan area. The survey was carried out in Marunouchi, Kanda, Kasai and Todoriki district. The results of this study were as follows; to propose of window area ratio production method, analyzed and surveyed window area ratio of each district building-used and to compared every wall window area ratio of building. Every wall window area ratio of office district is $20\sim40%$, ones of non-office district is 15% or 35%. Residential area results are every wall window area ratio of apartment is 35%, ones of a house is 15%. To increase of office building to appear that Kanda, Kasai added window area ratio. But, Marunouchi, Todoriki wad not this tendency. Above mentioned results are made out database.

A Study on the Strengthening effect of Concrete Reinforcement Bracket on the External Clay Brick Wall (외부치장적벽돌 벽체에 대한 콘크리트 보강브라켓의 보강효과에 관한 연구)

  • Kim, Sun-Woo;Kim, Yang-Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.117-118
    • /
    • 2020
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware (connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. The purpose of this study is to provide numerical information on the reinforcement design by experimentally studying the structural performance of concrete reinforcement brackets that reinforce the vertical load of the exterior wall.

  • PDF

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

Toward residential building energy conservation through the Trombe wall and ammonia ground source heat pump retrofit options, applying eQuest model

  • Ataei, Abtin;Dehghani, Mohammad Javad
    • Advances in Energy Research
    • /
    • v.4 no.2
    • /
    • pp.107-120
    • /
    • 2016
  • The aim of this research is to apply the eQuest model to investigate the energy conservation in a multifamily building located in Dayton, Ohio by using a Trombe wall and an ammonia ground source heat pump (R-717 GSHP). Integration of the Trombe wall into the building is the first retrofitting measure in this study. Trombe wall as a passive solar system, has a simple structure which may reduce the heating demand of buildings significantly. Utilization of ground source heat pump is an effective approach where conventional air source heat pump doesn't have an efficient performance, especially in cold climates. Furthermore, the type of refrigerant in the heat pumps has a substantial effect on energy efficiency. Natural refrigerant, ammonia (R-717), which has a high performance and no negative impacts on the environment, could be the best choice for using in heat pumps. After implementing the eQUEST model in the said multifamily building, the total annual energy consumption with a conventional R-717 air-source-heat-pump (ASHP) system was estimated as the baseline model. The baseline model results were compared to those of the following scenarios: using R-717 GSHP, R410a GSHP and integration of the Trombe wall into the building. The Results specified that, compared to the baseline model, applying the R-717 GSHP and Trombe wall, led to 20% and 9% of energy conservation in the building, respectively. In addition, it was noticed that by using R-410a instead of R-717 in the GSHP, the energy demand increased by 14%.

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope (외피 열성능에 따른 건물에너지효율등급 분석 연구)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.59-64
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

A Study on Simulation for Decreasing Energy Demand According to Window-to-Wall Ratio and Installation Blind System in Building (블라인드 도입과 창면적비에 따른 표준건축물의 에너지 수요 저감에 대한 시뮬레이션 연구)

  • Kang, Suk-Min;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.531-542
    • /
    • 2018
  • Building energy demands have highly risen in modern society; thus, It is necessary to reduce building energy demands especially commercial buildings adopting a curtain wall architecture. Curtain wall architectures have a high ratio of windows which is a vulnerable in heat insulations as cladding. In order to complement insulation performance of windows in these buildings, there are various methods adopted often such as installing blinds, wing wall and films. There are two suggestions of this paper. 1) WWR (Window-to-Wall Ratio) makes a impaction of energy demands in buildings. 2) Another one is an efficiency of blind systems which are installed in buildings in order to reduce cooling demands. It is also critical to make fundamental model for low-energy building construction by processing a lot of simulation As a result by this study, 1) an external blind system is more useful for reducing cooling energy demands rather than an internal blind system. 2) Buildings which have a large window require more amount of cooling demands. In case of WWR 45%, it needs more cooling energy rather than WWR 15% model's 3) Adopting blind system would reduce energy demands. WWR 45% model with external blind systems reduces about 4% of cooling energy demands compared to same model without any blind systems.4) it is necessary to study an efficiency of blind systems combined with renewable energy and it will be possible to reduce more energy demand in building significantly.

A Study on the Characteristics of Building the Japanese Castle at the Period of Japanese Invasion of Korea in 1592 and in 1597 (임진왜란과 정유재란시기 왜성 축조방법에 대한 연구)

  • Lee, Hyung-Jae
    • Journal of architectural history
    • /
    • v.18 no.1
    • /
    • pp.31-49
    • /
    • 2009
  • Periodically, the Japanese Castle was created in the domestic of Japan and then 2 Invasions into Chosun was started. The Japanese Castle in the domestic of Japan was repaired several times by the building boom of castle before & after 2 invasions and so the initially-built type of castles was changed. Accordingly, there are much difficulties to understand the original shape of Japanese Castle. Through the Japanese Castle within Korea called as the fossil of Japanese Castle, I would like to examine & consider its building period and characteristics. The terminology called as [Two Side Stone's Wall] is that of castle which is not acknowledged in the Japanese Academic Circles. However, it means the two-fold wall of Japanese Castle which was widely applied to the fortification way in the Age of Japan Edo. The terminology of [Sori] says the stonework curve in the corner of Japanese Castle which is indicated best in the Japanese Castle. It calls the curve as like the fan frame. [Curb Stone's Wall] says the type of castle wall constructed with over 1 face in wall body of Japanese Castle. (1) About classifying the construction period of Japanese Castle, the curb stone's wall and the castle having no two side stone's wall must consider the building period as that of Japanese Invasion of Korea in 1592. If there was [Sori], the two-side stone's wall was used and the place which supported the documentary data, in particular, the place having the record of contraction is considered to be confirmed as the castle constructed in the period of Japanese Invasion of Korea in 1597. (2) The two-side-type stone's wall shown in the Modern Japanese Stone Castle is difficultly considered to be generated from the Japanese Castle at the period of Japanese Invasion of Korea in 1592 and in 1597. (3) The beautiful [Sori] shown in the Modern Japanese Stone Castle was started from the Japanese Castle of Korea at the period of Japanese Invasion of Korea in 1597. It is difficultly considered which its indication was firstly generated by the Chaesung-Folded Segment Structure.

  • PDF

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Window and Wall in Apartment Houses (창호 및 벽체의 단열성능에 따른 건물에너지효율등급 평가 연구 -공동주택을 중심으로-)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Kim, Ji-Yeun;Jang, Cheol-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.608-613
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

  • PDF

Seismic Response Characterization of Shear Wall in Auxiliary Building of Nuclear Power Plant (지진에 의한 원전 보조건물 전단벽의동적 응답 특성 추정)

  • Rahman, Md Motiur;Nahar, Tahmina Tasnim;Baek, Geonhwi;Kim, Dookie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.93-102
    • /
    • 2021
  • The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.

An Economic Analysis of Irregular Wall Design Considering Effective Width (벽체의 유효폭을 고려한 이형벽체의 경제성 분석)

  • Han, Kyung-Soo;Bang, Jung-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.83-84
    • /
    • 2014
  • The whole wall system behaves as one section because single walls composing irregular wall are connected to each other. Although stress of a single wall is affected to the connected wall under lateral load, the stress is not transferred to whole sections and is concentrated on particular part of the wall as well. Therefore these walls can be divided into the effective and ineffective section. The purpose of this study is to compare design result of irregular wall using codes and previous studies on an effective width of the wall and to analyze reduction of the longitudinal bar of irregular wall.

  • PDF