• 제목/요약/키워드: Building Shape Factors

검색결과 104건 처리시간 0.027초

Evaluation of mode-shape linearization for HFBB analysis of real tall buildings

  • Tse, K.T.;Yu, X.J.;Hitchcock, P.A.
    • Wind and Structures
    • /
    • 제18권4호
    • /
    • pp.423-441
    • /
    • 2014
  • The high frequency base balance (HFBB) technique is a convenient and relatively fast wind tunnel testing technique for predicting wind-induced forces for tall building design. While modern tall building design has seen a number architecturally remarkable buildings constructed recently, the characteristics of those buildings are significantly different to those that were common when the HFBB technique was originally developed. In particular, the prediction of generalized forces for buildings with 3-dimensional mode shapes has a number of inherent uncertainties and challenges that need to be overcome to accurately predict building loads and responses. As an alternative to the more conventional application of general mode shape correction factors, an analysis methodology, referred to as the linear-mode-shape (LMS) method, has been recently developed to allow better estimates of the generalized forces by establishing a new set of centers at which the translational mode shapes are linear. The LMS method was initially evaluated and compared with the methods using mode shape correction factors for a rectangular building, which was wind tunnel tested in isolation in an open terrain for five incident wind angles at $22.5^{\circ}$ increments from $0^{\circ}$ to $90^{\circ}$. The results demonstrated that the LMS method provides more accurate predictions of the wind-induced loads and building responses than the application of mode shape correction factors. The LMS method was subsequently applied to a tall building project in Hong Kong. The building considered in the current study is located in a heavily developed business district and surrounded by tall buildings and mixed terrain. The HFBB results validated the versatility of the LMS method for the structural design of an actual tall building subjected to the varied wind characteristics caused by the surroundings. In comparison, the application of mode shape correction factors in the HFBB analysis did not directly take into account the influence of the site specific characteristics on the actual wind loads, hence their estimates of the building responses have a higher variability.

초고층건물에서의 풍력발전 적용을 위한 건물형태별 기류분석 (A Study on Analysis of Air Flow for Wind Power System by Shape of Super High-rise building)

  • 장호진;이동윤;박진철;이언구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.42-47
    • /
    • 2011
  • This study aims to choose installation location of wind power system and analyze influence factors of wind power system by shape of super high-raise building by using CFD simulation. As a result of this study, wind power system is more applicable to streamlined building than normal building. Round openings are seemed to be the most efficient shape for building integrated wind power system in types applying venturi effect. Safety and vibration should be considered in the case of application of wind power system between the buildings.

  • PDF

시뮬레이션 모형을 이용한 도시 개발형태 및 경관의 변화 예측 (Prediction of Urban Development and Cityscape with a Simulation Model)

  • 이인성;김충식
    • 한국조경학회지
    • /
    • 제32권3호
    • /
    • pp.106-113
    • /
    • 2004
  • The shapes(mass) of buildings are determined by many interrelated factors, such as planning and building regulations, the size and shape of building parcels, and adjoining road conditions. Understanding the effects of the determinants on the building shapes is not a simple task because of the multiplicity and complex interrelationships of the determinants. This study developed a prototype of three dimensional computer model that can simulates the determination process of building shape using GIS and CAD techniques. A commercial block in the south of Seoul was selected for the case study. Several methods of building height control were applied, and their effects on the cityscape were evaluated. The results shows that the three dimensional computer modelling offers an effective means for evaluating the effects of planning and building regulations. The implication of the case study and future research directions were discussed.

Estimation of wind pressure coefficients on multi-building configurations using data-driven approach

  • Konka, Shruti;Govindray, Shanbhag Rahul;Rajasekharan, Sabareesh Geetha;Rao, Paturu Neelakanteswara
    • Wind and Structures
    • /
    • 제32권2호
    • /
    • pp.127-142
    • /
    • 2021
  • Wind load acting on a standalone structure is different from that acting on a similar structure which is surrounded by other structures in close proximity. The presence of other structures in the surrounding can change the wind flow regime around the principal structure and thus causing variation in wind loads compared to a standalone case. This variation on wind loads termed as interference effect depends on several factors like terrain category, geometry of the structure, orientation, wind incident angle, interfering distances etc., In the present study, a three building configuration is considered and the mean pressure coefficients on each face of principle building are determined in presence of two interfering buildings. Generally, wind loads on interfering buildings are determined from wind tunnel experiments. Computational fluid dynamic studies are being increasingly used to determine the wind loads recently. Whereas, wind tunnel tests are very expensive, the CFD simulation requires high computational cost and time. In this scenario, Artificial Neural Network (ANN) technique and Support Vector Regression (SVR) can be explored as alternative tools to study wind loads on structures. The present study uses these data-driven approaches to predict mean pressure coefficients on each face of principle building. Three typical arrangements of three building configuration viz. L shape, V shape and mirror of L shape arrangement are considered with varying interfering distances and wind incidence angles. Mean pressure coefficients (Cp mean) are predicted for 45 degrees wind incidence angle through ANN and SVR. Further, the critical faces of principal building, critical interfering distances and building arrangement which are more prone to wind loads are identified through this study. Among three types of building arrangements considered, a maximum of 3.9 times reduction in Cp mean values are noticed under Case B (V shape) building arrangement with 2.5B interfering distance. Effect of interfering distance and building arrangement on suction pressure on building faces has also been studied. Accordingly, Case C (mirror of L shape) building arrangement at a wind angle of 45º shows less suction pressure. Through this study, it was also observed that the increase of interfering distance may increase the suction pressure for all the cases of building configurations considered.

유럽 집합주택의 입면 디자인 요소에 관한 연구 - 1980년대 이후 사례를 중심으로 - (A Study on the Elevation and Facade Design Factors of European Multistory-Housing)

  • 김준래;전남일
    • 한국주거학회논문집
    • /
    • 제21권5호
    • /
    • pp.23-33
    • /
    • 2010
  • In the late twentieth century, the multistory housing has become the most preferred housing type. Moreover, in multistory housing design, not only interior design but also exterior design, uniqueness and characteristic have been added as significant factors in design to break simplicity and uniformity. The purpose of this study is to understand the tendency of the elevation design in Europe and to suggest the idea for elevation design for domestic. Also, each elements of elevation were analyzed through classification and schematization which categorized by its own characteristic. Design elements can be classified into three categories. They are corresponding with inner spaces, emphasizing visual expression of exterior material and texture, and presenting aesthetic factors of building shape. Those are named as the Spatial Externalization, the Visual Expression, and the Expression of Building Shape. In this frame nineteen elevations of sixteen different cases were analysed. As a result of case studies, it is clear that elevation designs were not standardized and each cases has its own characteristics. Also it showed how the each design elements can be coordinated as a total design and how they expressed identities of each housing. This study could contribute to motivate diversifying the design of multistory housing.

Design Optimization Using Conflicting Building Information - A case Study Focused on the View and Structure in High-Rise Building Design

  • Cheon, Janghwan
    • Architectural research
    • /
    • 제15권2호
    • /
    • pp.69-75
    • /
    • 2013
  • Within residential high-rise market there are many value determining factors. Site condition, view, program, units and structure are important parameters that are directly related to the financial aspect of the project. However, most of the studies of high-rise building design focus on the facade and the shape strategies from an esthetic point of view without considering these factors. The objective of this study is to investigate new design approach that incorporates site, program and structural information at an early stage as a generator of building form and explore a wide range of strategies to negotiate these factors in the process of design/decision making. Not being based on designer's subjective preference or style, architects still can create interesting building design through integration and negotiation of various building information. Since this form is based on real data, not just play of form, we can expect that this form has great potential to be developed into real one at the later design phase.

The Development of Automatic Module for Formwork Layout using the BIM

  • Chijoo Lee;Sungil Ham;Ghang Lee
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1266-1271
    • /
    • 2009
  • Formwork layout is perceived as important due to its strong tie to site works. But, most formwork is done manually and influenced by worker's skill and thus, a lot of construction errors occur. The introduction of BIM (Building Information Modeling) enables acquiring more precise information on the building shape, dimension, structure, etc. than 2D-based drawings and thus, the increased productivity, such as reduction of workload and work times, and the economic efficiency, such as reduction of formwork types and form dimensions with the consideration of constructability, are expected. This study reviewed the previous studies and formwork layout systems to derive this study's differentiations and factors to be first considered for formwork planning were derived by analyzing priorities against consideration factors. Last, a flow chart and algorithm were developed to apply the derived factors to the formwork layout module.

  • PDF

건물의 외주길이와 안전관리비의 상관관계 분석에 관한 연구 (A Study on the Correlation between the Building Perimeter and Safety Management Cost)

  • 한범진
    • 한국건축시공학회지
    • /
    • 제22권4호
    • /
    • pp.359-370
    • /
    • 2022
  • 현장의 안전사고율을 낮추려는 지속적인 노력에도 불구하고 여전히 건설산업은 치명적인 사고율이 높은 고위험군으로 분류된다. 건설 안전사고율을 낮추기 위한 방법 중 하나로 설계 단계에서 안전위해요소를 관리하는 DFS(Design for safety)를 적용하고 있다. 그러나 설계자의 제한된 지식 때문에 설계 결과가 건설, 운영 및 유지보수와 같은 project lifecycle 동안 어떤 위험을 초래하는지 설계자는 인식하지 못하는 경우가 많다. 만일 설계자가 건물의 형상이 안전사고율에 미치는 영향과 이에 대응하는 안전관리비에 미치는 영향을 이해한다면, 효과적인 DFS를 진행할 수 있다. 안전관리비중 가장 많은 비중을 차지하는 낙하방지 그물망, 안전 펜스와 같은 안전시설비는 동일 건축면적이라 하더라도 건물의 형상에 따라 달라질 것이다. 본 연구의 목적은 건물의 외주길이가 안전관리비에 미치는 영향을 분석하는 것이다. 아파트(apartment building)를 대상으로 건물의 외주길이가 안전관리비에 미치는 영향을 분석한다. 본 연구를 위해 21개의 프로젝트 데이터를 수집한 후 외주길이와 건물형상계수, 건축면적을 독립변수로 안전관리비를 종속변수로 분석한다. 그 결과 외주길이와 안전관리비의 상관관계는 R2가 0.876, 형상계수와 안전관리비의 상관관계는 R2가 0.801, 건축면적과 안전관리비의 상관관계는 R2가 0.792로 매우 밀접한 관계가 있는 것으로 분석되었다.

공동주택의 건물외부조건과 에너지비용과의 관계분석 (Relation between the Building Exterior Conditions and Energy Costs in the Running period of the Apartment Housing)

  • 이강희;류승훈;이은택
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.107-113
    • /
    • 2009
  • The energy cost is resulted from the energy use. Its sources are divided into some types and depended on the building use or energy-use type. The energy cost should be affected by the amount of the energy use. The cost could be calculated to consider various factors such as the insulation, heating type, building shape and others. But it can not consider all of the affect factors to the energy cost and need to categorize the factors to the condition for estimating the cost. In this paper, it aimed at providing the estimation model in linear equation and multiple linear regression, utilizing the building exterior condition and management characteristics in apartment housing. Its survey are conducted in two parts of management characteristics and building exterior condition. The correlation analysis is conducted to get rid of the multicolinearity among the inputted factors. The number of linear equation model is 11 and includes the 1st, 2nd and 3rd equation function, power function and others. Among these, it suggested the 2nd and 3rd function and power function in terms of the statistics. In multiple linear regression model, the building volume and management area are inputted to the estimation.

Wind tunnel study on fluctuating internal pressure of open building induced by tangential flow

  • Chen, Sheng;Huang, Peng;Flay, Richard G.J.
    • Wind and Structures
    • /
    • 제32권2호
    • /
    • pp.105-114
    • /
    • 2021
  • This paper describes a wind tunnel test on a 1:25 scale model of TTU building with several adjustable openings in order to comprehensively study the characteristics of fluctuating internal pressures, especially the phenomenon of the increase in fluctuating internal pressures induced by tangential flow over building openings and the mechanism causing that. The effects of several factors, such as wind angle, turbulence intensity, opening location, opening size, opening shape and background porosity on the fluctuating internal pressures at oblique wind angles are also described. It has been found that there is a large increase in the fluctuating internal pressures at certain oblique wind angles (typically around 60° to 80°). These fluctuations are greater than those produced by the flow normal to the opening when the turbulence intensity is low. It is demonstrated that the internal pressure resonances induced by the external pressure fluctuations emanating from flapping shear layers on the sidewall downstream of the windward corner are responsible for the increase in the fluctuating internal pressures. Furthermore, the test results show that apart from the opening shape, all the other factors influence the fluctuating internal pressures and the internal pressure resonances at oblique wind angles to varying degrees.