Browse > Article
http://dx.doi.org/10.12989/was.2014.18.4.423

Evaluation of mode-shape linearization for HFBB analysis of real tall buildings  

Tse, K.T. (Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology)
Yu, X.J. (Department of Civil and Environmental Engineering, Hong Kong University of Science and Technology)
Hitchcock, P.A. (CLP Power Wind/Wave Tunnel Facility, Hong Kong University of Science and Technology)
Publication Information
Wind and Structures / v.18, no.4, 2014 , pp. 423-441 More about this Journal
Abstract
The high frequency base balance (HFBB) technique is a convenient and relatively fast wind tunnel testing technique for predicting wind-induced forces for tall building design. While modern tall building design has seen a number architecturally remarkable buildings constructed recently, the characteristics of those buildings are significantly different to those that were common when the HFBB technique was originally developed. In particular, the prediction of generalized forces for buildings with 3-dimensional mode shapes has a number of inherent uncertainties and challenges that need to be overcome to accurately predict building loads and responses. As an alternative to the more conventional application of general mode shape correction factors, an analysis methodology, referred to as the linear-mode-shape (LMS) method, has been recently developed to allow better estimates of the generalized forces by establishing a new set of centers at which the translational mode shapes are linear. The LMS method was initially evaluated and compared with the methods using mode shape correction factors for a rectangular building, which was wind tunnel tested in isolation in an open terrain for five incident wind angles at $22.5^{\circ}$ increments from $0^{\circ}$ to $90^{\circ}$. The results demonstrated that the LMS method provides more accurate predictions of the wind-induced loads and building responses than the application of mode shape correction factors. The LMS method was subsequently applied to a tall building project in Hong Kong. The building considered in the current study is located in a heavily developed business district and surrounded by tall buildings and mixed terrain. The HFBB results validated the versatility of the LMS method for the structural design of an actual tall building subjected to the varied wind characteristics caused by the surroundings. In comparison, the application of mode shape correction factors in the HFBB analysis did not directly take into account the influence of the site specific characteristics on the actual wind loads, hence their estimates of the building responses have a higher variability.
Keywords
HFBB; linear-mode-shape method; real tall building application; various site wind conditions; effects of surroundings;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chen, X. and Kareem, A. (2004), "Equivalent static wind loads on buildings: new model", J. Struct. Eng. - ASCE, 130(10), 1425-1435.   DOI   ScienceOn
2 Davenport, A.G. and Tschanz, T. (1981), "The response of tall buildings to wind", Proceedings of the 4th U.S. Nat. Conf. of Wind Engineering, July 27-29, Seattle, Washington, U.S.A.,
3 Gere and Timoshenko, S. (1997), Mechanics of materials, PWS Publishing Company.
4 Holmes, J.D., Rofail, A. and Aurelius, L. (2003), "High frequency base balance methodologies for tall buildings with torsional and coupled resonant modes", Proceedings of the 11th International Conf. on Wind Engineering, June 1-5, Lubbock, Texas, U.S.A.
5 Li, H.N., Yi, T.H., Yi, X.D. and Wang, G.X. (2007), "Measurement and analysis of wind-induced response of tall building based on GPS technology", Adv. Struct. Eng., 10(1), 83-93   DOI   ScienceOn
6 Standards Australia (2011), Australian/New Zealand Standard, Structural design actions Part 2: Wind actions, AS/NZS 1170.2:2011, Standards Australia, Sydney, N.S.W, Australia
7 Tschanz, T. and Davenport, A.G. (1983), "The base balance technique for the determination of dynamic wind loads", J. Wind Eng. Ind. Aerod., 13(1-3), 429-439.   DOI   ScienceOn
8 Tse, K.T., Hitchcock, P.A. and Kwok, K.C.S. (2009), "Mode shape linearization for HFBB analysis of wind-excited complex tall buildings", Eng. Struct., 31(3), 675-685.   DOI   ScienceOn
9 Tse, K.T., Kwok, K.C.S., Hitchcock, P.A., Samali, B. and Huang, M.F. (2007), "Vibration control of a wind-excited benchmark tall building with complex lateral-torsional modes of vibration", Adv. Struct. Eng., 10(3), 283-304.   DOI   ScienceOn
10 Boggs, D.W. and Peterka, J.A. (1989), "Aerodynamic model tests of tall buildings", J. Eng. Mech. -ASCE, 115(3), 618-635.   DOI   ScienceOn
11 Buildings Department (HKSAR) (2004), Code of Practice on Wind Effects in Hong Kong.
12 Xu, Y.L. and Kwok, K.C.S. (1993), "Mode shape corrections for wind tunnel tests of tall buildings", Eng. Struct., 15(5), 387-392.   DOI   ScienceOn
13 Lam, K.M. and Li, A. (2009), "Mode shape correction factors for wind-induced dynamic responses of tall buildings using time-domain computation and wind tunnel tests", J. Sound Vib., 322 (4-5), 740-755.   DOI   ScienceOn
14 Holmes, J.D. (1987), "Mode shape correction factors for dynamic response to wind", Eng. Struct., 9(3), 210-212.   DOI   ScienceOn