• Title/Summary/Keyword: Building Infrastructure

Search Result 1,205, Processing Time 0.028 seconds

Information Modeling of Railway Track using Information Iinkage of Railway Alignment and Alignment-based Objects (철도 선형중심의 객체 정보연계를 통한 철도 궤도부 정보모델 생성 방안)

  • Kwon, Tae Ho;Park, Sang I.;Shin, Min Ho;Lee, Sang-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.507-514
    • /
    • 2017
  • As BIM has been widely used in the field of architecture, efforts to apply BIM to civil engineering structures are increasing rapidly. Since commercial BIM softwares are focused on building structure, it is difficult to apply to alignment-based civil infrastructures. In this study, we proposed a method to generate an information model that reflects cant by sharing information between alignment-centered modeling tools and BIM authoring tools to manage information of railway track. The railway track modeling process consists of classifying structures into continuous and non-continuous structures, creating continuous structures by alignment-centered modeling tools, and using the shared alignment information to generate information model of the non-continuous structures. Non-continuous structures were generated by an algorithm that calculates the position and rotation information of each structure based on discretized railway alignment and cant information transmitted to the BIM authoring tools. The availabilities of proposed method were studied by applying to the osong test-line. Using the test model, it was shown that the objects were identified, the properties were extracted, and the quantities of each structure were calculated.

A Study on 3D Model Building of Drones-Based Urban Digital Twin (드론기반 도심지 디지털트윈 3차원 모형 구축에 관한 연구)

  • Lim, Seong-Ha;Choi, Kyu-Myeong;Cho, Gi-Sung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.1
    • /
    • pp.163-180
    • /
    • 2020
  • In this study, to build a spatial information infrastructure, which is a component of a smart city, a 3D digital twin model in the downtown area was built based on the latest spatial information acquisition technology, the drone. Several analysis models were implemented by utilizing. While the data processing time and quality of the three types of drone photogrammetry software are different, the accuracy of the construction model is ± 0.04 in the N direction and ± 0.03m in the E direction. In the m and Z directions, ± 0.02m was found to be less than 0.1m, which is defined as the allowable range of surveying performance and inspection performance for the boundary point in the area where the registration of the boundary point registration is executed. 1: 500 to 1 of the aerial survey work regulation: The standard deviation, which is the error limit of the photographic reference point of the 600 scale, appeared within 0.14 cm, and it was found that the error limit of the large scale specified in the cadastral and aerial survey was satisfied. In addition, in order to increase the usability of smart city realization using a drone-based 3D urban digital twin model, the model built in this study was used to implement Prospect right analysis, landscape analysis, Right of light analysis, patrol route analysis, and fire suppression simulation training. Compared to the existing aerial photographic survey method, it was judged that the accuracy of the naked eye reading point is more accurate (about 10cm) than the existing aerial photographic survey, and it is possible to reduce the construction cost compared to the existing aerial photographic survey at a construction area of about 30㎢ or less.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Knowledge-driven Dynamic Capability and Organizational Alignment: A Revelatory Historical Case

  • Kim, Gyeung-Min
    • Asia pacific journal of information systems
    • /
    • v.20 no.1
    • /
    • pp.33-56
    • /
    • 2010
  • The current business environment has been characterized as less munificent, highly uncertain and constantly evolving. In this environment, the company with dynamic capability is reported to be more successful than others in building competitive advantage. Dynamic capability focuses on the link between a dynamically changing environment, strategic agility, architectural reconfiguration, and value creation. Being characterized to be flexible and adaptive to market circumstance changes, an organization with dynamic capability is described to have high resource fluidity, which represents business process, resource allocation, human resource management and incentives that make business transformation faster and easier. Successful redeployment of the resources for dynamic adaptation requires organizational forms and reward systems to be well aligned with firm's technological infrastructures and business process. The alignment is considered to be an executive level commitment. Building dynamic capability is knowledge driven; relying on new knowledge to reconfigure firm's resources. Past studies established the link between the effective execution of a knowledge-focused strategy and relevant setting of architectural elements such as human resources, structure, process and information systems. They do not, however, describe in detail the underlying processes by which architectural elements are adjusted in coordinated manners to build knowledge-driven dynamic capability. In fact, understandings of these processes are one of the top issues in IT management. This study analyzed how a Korean corporation with a knowledge-focused strategy aligned its architectural elements to develop the dynamic capability and thus create value in the dynamically changing markets. When the Korean economy was in crisis, the company implemented a knowledge-focused strategy, restructured the organization's architecture by which human and knowledge resources are identified, structured, integrated and coordinated to identify and seize market opportunity. Specifically, the following architectural elements were reconfigured: human resource, decision rights, reward and evaluation systems, process, and IT infrastructure. As indicated by sales growth, the reconfiguration helped the company create value under an extremely turbulent environment. According to Ancona et al. (2001), depending on the types of lenses the organization uses, different types of architecture will emerge. For example, if an organization uses political lenses focusing on power, influence, and conflict. the architecture that leverage power and negotiate across multiple interest groups would emerge. Similarly, if an organization uses economic lenses focusing on the rational behavior of organizational actors making choices based on the costs and benefits of action, organizational architecture should be designed to motivate and provide incentives for the actors (Smith, 2001). Compared to this view, information processing perspectives consider architecture to be designed to maximize the capacity of information processing by the actors. Using knowledge lenses, the company studied in this research established architectural elements in a manner that allows the firm to effectively structure knowledge resources to form dynamic capability. This study is revelatory single case with a historic perspective. As a result of this study, a set of propositions and a framework are derived, which can be used for architectural alignment.

Dispute Issues and Improvement of Inter-layer Joints in Apartment Houses (공동주택 층간이음부의 분쟁 쟁점 및 개선 방안)

  • Bang, Hong-Soon;Bae, In-ho;Kim, Ok-Kyue
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.2
    • /
    • pp.129-139
    • /
    • 2021
  • Recent rise in the supply rate of new public apartment houses leads to an increasement in disputes regarding the construction quality of the apartments between the residents and the construction companies. According to the dispute cases filed for claiming the collective defect repair fees, inter-layer concrete joints turned out to be the most frequently disputed item. For this reason, this study selects the inter-layer concrete joints to further analyze the primary causes and details of each dispute case. From the results of this study, three primary causes of the disputes are found, which are 1) the absence of standard specifications for construction quality control and management after construction; 2) the absence of established standards for repair when construction defects are found; and 3) the fact that the court grants generous compensation for disputes concerning the apartment houses. In order to prevent construction defects in inter-layer concrete joints, this study provides three suggestions including 1) the current standard specifications for inter-layer concrete joints should be further specified by the Ministry of Land, Infrastructure and Transport; 2) a construction defect should be judged according to the compliance to the standard specifications; and 3) a clear and institutional protocol needs to be established for defect repair in cases that new public apartment houses have been judged to have defects.

Radiation Flux Impact in High Density Residential Areas - A Case Study from Jungnang area, Seoul - (고밀도 주거지역에서의 복사플럭스 영향 연구 - 서울시 중랑구 지역을 대상으로 -)

  • YI, Chae-Yeon;KWON, Hyuk-Gi;Lindberg, Fredrik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.4
    • /
    • pp.26-49
    • /
    • 2018
  • The purpose of this study was to verify the reliability of the solar radiation model and discuss its applicability to the urban area of Seoul for summer heat stress mitigation. We extended the study area closer to the city scale and enhanced the spatial resolution sufficiently to determine pedestrian-level urban radiance. The domain was a $4km^2$ residential area with high-rise building sites. Radiance modelling (SOLWEIG) was performed with LiDAR (Light Detection and Ranging)-based detailed geomorphological land cover shape. The radiance model was evaluated using surface energy balance (SEB) observations. The model showed the highest accuracy on a clear day in summer. When the mean radiation temperature (MRT) was simulated, the highest value was for a low-rise building area and road surface with a low shadow effect. On the other hand, for high-rise buildings and vegetated areas, the effect of shadows was large and showed a relatively low value of mean radiation temperature. The method proposed in this study exhibits high reliability for the management of heat stress in urban areas at pedestrian height. It is applicable for many urban micro-climate management functions related to natural and artificial urban settings; for example, when a new urban infrastructure is planned.

An Analysis of the Policy Effect on the Change of Application Standard of Floor Area Ratio for Land Covering Two or More Zoning Area - Focused on Gangnam-gu - (둘 이상의 용도지역 등에 걸치는 대지에 대한 용적률 적용기준 변경의 정책적 효과분석 - 강남구를 중심으로 -)

  • Yu, Myeong-Han;Lee, Chang-Moo
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.2
    • /
    • pp.121-135
    • /
    • 2018
  • The ministry of land, Infrastructure and transport has revised the "National Land Planning and Utilization Act" in 2012. As a result, the regulation of floor area ratio for land covering two or more zoning area has been changed. This study conducted an analysis of the policy effects of changes in the criteria for the application of the floor area ratio by revising the "National Land Planning and Utilization Act". Land covering two or more zoning area means a street side commercial area and street side residential area that is generally understood. This study analyzed the policy effects in Gangnam-gu which has relatively large areas of street side commercial area and street side residential area. The 468 office building transaction cases were analyzed in Gangnam-gu from 2007 to 2017. The result shows that the office building, which has received incentive for policy changes, reported a 19.08% rise in price compared to the one that did not. It means that the economic effects of change of application standard were significant. The existing policy also served as a restriction on land use by landowners, which in turn contributed to the devaluation of the asset's intrinsic value. Therefore, this study may have contributed to the rational use of land and to provide an empirical basis for the change in policy to be assessed for its intrinsic value.

Direct Tensile Properties of Fiber-Reinforced Cement Based Composites according to the Length and Volume Fraction of Amorphous Metallic Fiber (비정질 강섬유의 길이 및 혼입률에 따른 섬유보강 시멘트복합체의 직접인장특성)

  • Kim, Hong-Seop;Kim, Gyu-Yong;Lee, Sang-Kyu;Choe, Gyeong-Cheol;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.201-207
    • /
    • 2019
  • In this study, the direct tensile properties of amorphous metallic fiber-reinforced cement based composites according to the strain was evaluated. A thin plate-shape amorphous metallic fiber with 15mm and 30mm in length was used. And fiber-reinforced cement based composites were prepared with contents of 1.0, 1.5, 2.0%. The direct tensile test was conducted under the conditions of $10^{-6}/s(static)$ and $10^1/s(dynamic)$ strain rate. As a results, amorphous metallic fiber with a length of 15mm was observed in pull-out behavior from the cement matrix because of the short fiber length and large portion of mixed fiber. On the other hand, amorphous metallic fiber with a length of 30mm were not pulled out from matrix because the bonding force between the fiber and matrix was large due to rough surface and large specific surface area. However, fracture occurred because thin plate shape fibers were vulnerable to shear force. Tensile strength, strain capacity and toughness were improved due to the increase in the fiber length. The dynamic increase factor of L15 was larger that of L30 because the bonding performance of the fiber-matrix interface is significantly affected by the strain rate.

Evaluation of Electromagnetic Pulse Shielding Effectiveness and Bonding Performance of Inorganic Paint based on Carbon Material (탄소재료 기반 무기계 도료의 전자파 차폐성능 및 부착성능 평가)

  • Jang, Kyong-Pil;Kim, Sang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.801-807
    • /
    • 2021
  • In various industrial fields and infrastructure based on electronic components, such as communication equipment, transportation, computer networks, and military equipment, the need for electromagnetic pulse shielding has increased. Two methods for applying electromagnetic pulse shielding are effective. The first is construction using shielding materials, such as shielding concrete, shielding doors, and shielding windows. The other is coating shielding paints on non-shielding structures. Electromagnetic pulse shielding paints are made using conductive materials, such as carbon nanotubes, graphite, carbon black, and carbon fiber. In this paint, electromagnetic pulse shielding performance is added to the commonly used water-based paint. In this study, the shielding effectiveness and bonding performance of paints using conductive graphite and carbon black as shielding materials were evaluated to develop electromagnetic pulse shielding inorganic paints. The shielding effectiveness and bonding performance were evaluated by applying six mixtures composed of different kinds and amounts of shielding material. The mixture of conductive graphite and carbon black at a weight ratio of 1:0.2 was the most effective in shielding as 33.6 dB. Furthermore, the mixture produced using conductive graphite only showed the highest bonding performance of 1.06 MPa.

Investigation on the Preparation Method of TiO2-mayenite for NOx Removal (질소산화물 제거를 위한 TiO2-mayenite 제조 방법에 관한 연구)

  • Park, Ji Hye;Park, Jung Jun;Park, Hee Ju;Yi, Kwang Bok
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.304-310
    • /
    • 2020
  • In order to apply a photocatalyst (TiO2) to various building materials, TiO2-mayenite was prepared in this study. The TiO2 was synthesized using the sol-gel method by fixing titanium isopropoxide (TTIP) and urea at a ratio of 1 : 1. Later, they were calcined in a temperature range of 400-700 ℃ to analyze the properties according to temperature. BET, TGA, and XRD were used to analyze the physical and chemical properties of TiO2. The nitrogen oxide removal test was confirmed by measuring the change in the concentration of NO for 1 h according to KS L ISO 22197-1. The prepared TiO2 samples exhibited an anatase crystal structure below 600 ℃, and TiO2 (urea)-400 showed the highest nitrogen oxide removal rate at 2.35 µmol h-1. TiO2-mayenite was prepared using two methods: spraying TiO2 dispersion solution (s/s) and sol-gel solution (g/s). Through BET and XRD analysis, it was found that 5-TiO2 (g/s) prepared by spraying a sol-gel solution has maintained its crystallinity even after heat treatment. Also, 5-TiO2 (g/s)-500 showed the highest removal rate of 0.55 µmol h-1 in the nitrogen oxide removal test. To prepare TiO2-mayenite, it was confirmed that mayenite should be blended with TiO2 in a sol-gel state to maintain the crystal structure and exhibit a high nitrogen oxide removal rate.