• Title/Summary/Keyword: Building Information Control

Search Result 682, Processing Time 0.028 seconds

An Implementation of a GPS Signal Generator based on FPGA and Indoor Positioning System (FPGA를 기반으로 한 GPS 신호생성기 구현 및 실내측위 시스템)

  • Choi, Jun-hyeok;Kim, Young-Geun;Ahn, Myung-Soo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.38-43
    • /
    • 2015
  • This paper describes a GPS signal generator that can generate multiple satellite signals in real time at the RF level. It realizes the verified software algorithm on a FPGA. The algorithm models orbits and environmental errors such as ionospheric and tropospheric multipath. The position of a simulated receiver is one of simulation parameters. The hardware which consists of a digital logic board and an analog board can generate 16 simulated satellites signals at the same time. The users can generate spoofing signals and jamming signals as well as satellite signals by using the windows-based control software. In addition, the software provides GIS-based simulation scenarios editing tools. We verified the generator by using commercial receivers. As an application, we configured generators as indoor positioning systems and tested them in a building. To improve the accuracy of indoor systems is our further study.

Development of Real time distributed Object Remote Monitroing system (실시간 분산객체 원격 모니터링 시스템의 개발)

  • Moon, Myung-Ho;Koo, Kyung-Wan
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • As information communication technology developed we could monitor temperature, weather, indoor and outdoor status which we need to monitor using various sensors. Even further we could monitor our body such as Sa02 and serologic chemical tests easily at home or office. It is possible though interlocking the house medical instrument with the wireless public data network. Data from sensors can be transmitted to the distant control room and will be essentially applied through wireless public data network. In this study we measured various sensor data for the telemetry in one system. The sensing items are mainly focused on the static and dynamic behaviors of the bridge, building, instruments. The study suggests the transmit system model utilized by the wireless public data network. The suggestion in the study of telemetry system provides movement and preservation. And it will exam various condition in distance or at home.

  • PDF

Software Size Estimation Model for 4GL System (4GL 시스템에 대한 소프트웨어 크기 추정 모델)

  • Yoon, Myoung-Young
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1999.05a
    • /
    • pp.97-105
    • /
    • 1999
  • An important task for any software project manager is to be able to predict and control project size. Unfortunately, there is comparatively little work that deals with the problem of building estimation methods for software size in fourth-generation languages systems. In this paper, we propose a new estimation method for estimating for software size based on minimum relative error(MRE) criterion. The characteristic of the proposed method is insensitive to the extreme values of the observed measures which can be obtained early in the development life cycle. In order to verify the performance of the proposed estimation method for software size in terms of both quality of fit and predictive quality, the experiments has been conducted for the dataset I and II, respectively. For the data set I and II, our proposed estimation method was shown to be superior to the traditional method LS and RLS in terms of both the quality of fit and predictive quality when applied to data obtained from actual software development projects.

  • PDF

Hong Kong Chinese Women's Lay Beliefs about Cervical Cancer Causation and Prevention

  • Wang, Linda Dong-Ling;Lam, Wendy Wing Tak;Wu, Joseph;Fielding, Richard
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7679-7686
    • /
    • 2014
  • Background: This study aimed to seek insights into Chinese women's lay beliefs about cervical cancer causal attributions and prevention. Materials and Methods: Twenty-three new immigrant adult women from Mainland China and thirty-five Hong Kong adult women underwent semi-structured in-depth interviews. Interviews were audio taped, transcribed and analyzed using a Grounded Theory approach. Results: This study generated three foci: causal beliefs about cervical cancer, perceived risk of cervical cancer, and beliefs about cervical cancer prevention. Personal risky practices, contaminated food and environment pollution were perceived as the primary causes of cervical cancer. New immigrant women more likely attributed cervical cancer to external factors. Most participants perceived cervical cancer as an important common fatal female cancer with increased risk/prevalence. Many participants, particularly new immigrant women participants, expressed helplessness about cervical cancer prevention due to lack of knowledge of prevention, it being perceived as beyond individual control. Many new immigrant participants had never undergone regular cervical screening while almost all Hong Kong participants had done so. Conclusions: Some Chinese women hold pessimistic beliefs about cervical cancer prevention with inadequate knowledge about risk factors. Future cervical cancer prevention programs should provide more information and include capacity building to increase Chinese women's knowledge and self-efficacy towards cervical cancer prevention.

Research on the actual vibration exposure of workers engaging in vibration induced works (진동작업 종사 근로자의 진동노출 실태에 관한 연구)

  • Kim, Kab-Bae;Chung, Eun-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.178-185
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 949 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to $1.7{\sim}2.8m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were $7.1{\sim}10.8m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were $3.3{\sim}11.1m/s^2$. Workers using a impact wrench were exposed to $1.5{\sim}1.6m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplaces to control vibration was not much different from the past because there are no vibration exposure limit.

  • PDF

Digitally controlled phase-locked loop with tracking analog-to-digital converter (Tracking analog-to-digital 변환기를 이용한 digital phase-locked loop)

  • Cha, Soo-Ho;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.9 s.339
    • /
    • pp.35-40
    • /
    • 2005
  • A digitally controlled phase-locked loop (DCPLL) is described. The DCPLL has basically the same structure as a conventional analog PLL except for a tracking analog-to-digital converter (ADC). The tracking ADC generates the control signal for voltage controlled oscillator. Since the DCPLL employs neither digitally controlled oscillator nor time-to-digital converter-the key building blocks of digital PLL (DPLL), there is no need for the 03de-off between jitter, power consumption and silicon area. The DCPLL was implemented in a $0.18\mu$m CMOS process and the active area is 1mm $\times$0.35 mm The DCPLL consumes S9mW during the normal opuation and $984\{mu}W$ during the power-down mode from a 1.8V supply. The DCPLL shows 16.8ps ms jitter.

A Method to Establish NCOE of Separated Theater by Architecting (아키텍팅 기법을 활용한 분리된 전구의 NCOE 구축방안)

  • Jang, Dong-Mo;Lee, Chul-Hwa;Lee, Tae-Gong;Lim, Jae-Sung
    • Journal of Information Technology and Architecture
    • /
    • v.9 no.2
    • /
    • pp.143-154
    • /
    • 2012
  • With the realization of the importance of the NWI, iterated by the Cheonan Ship sink and the YP-Do shelling, this thesis separates the NWI from the peninsula, regarding it separate from the Korea Theater of Operations, and suggests the method to establish NCOE with consideration to the characteristics of separated theater as well as the current situation. Although the NWI holds strategic value, systematical NCOE of surveillance and reconnaissance system, command and control system, and precision strike system is not yet established. Pertaining to this issue, Architecting was utilized to identify improvement measures and of the identified improvement measures, improvement on the "strike on nK hardened artillery sites with K-9 Self-Propelled Artillery in correlations with theater ISR" shows greatly improved strike effects when conducting simulations based on the Operation-Plan Analysis Model. Such a method of NCOE establishment will serve as a standard model for military force building and operation execution system for separated theater operations such as the NWI.

Ground Vibration Test for Korea Sounding Rocket - III (KSR-III의 전기체 모달 시험)

  • 우성현;김영기;이동우;문남진;김홍배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.441-447
    • /
    • 2002
  • KSR-III(Korea Sounding Rocket - III), which is being developed by Space Technology R&D Division of KARI(Korea Aerospace Research Institute) will be launched in late 2002. It is a three-stage, liquid propellant rocket which can reach 250 km altitude and will carry out observation of ozone layer and scientific experiments, such as microgravity experiment, and atmospheric measurement. KSR-III is believed to be an intermediate to the launch vehicle capable of carrying a satellite to its orbit. Space Test Department of KARI performed GVT(Ground Vibration Test) fer KSR-III EM at Rocket Test Building of KARI. GVT is very important for predicting the behavior of rocket in its operation, developing flight control program and performing aerodynamic analysis. This paper gives an introduction of rocket GVT configuration and information on test procedures, techniques and results of It. In this test. to simulate free-free condition, test object hung in the air laterally by 4 bungee cords specially devised. For the excitation of test object, pure random signal by two electromagnetic shakers was used and total 22 frequency response functions were achieved. Polyreference parameter estimation was performed to identify the modal parameters with MIMO(Multi-Input-Multi-Output) method. As the result of the test, low frequency mode shapes and modal parameters below 60Hz were identified

  • PDF

Study on the Building of Digital Terrain Model Using Satellite Remotely Sensed Data and Its Applications (위성 원격탐사 데이타를 이용한 지형표고모델 산출 알고리즘 구축 및 응용)

  • 최윤수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.2
    • /
    • pp.141-151
    • /
    • 1995
  • In generating DTM as basic data to GIS, the use of existing map is difficult to aquire current data and the method using airphotos needs cost for stereoplotting and ground control surveying. So, the method of DTM generation by satellite imagery is promising because satellite is able to observe wide area at once. In this study the program for SPOT bundle adjustment and image matching based on Coarse to Fine method is developed and various image enhancement algorithm is used for more accurate DTM generation and also evaluation of accuracy was carried out. Further more, orthophoto, a bird's eye-view, contour map producing, net-work analysis and terrain analysis were performed for GIS applications using generated DTM in this study. Generated DTM using SPOT stereo imagery is useful for GIS applications such as automated mapping, facility management, national geographic information system. Moreover developed automatic DTM generation pro-gram is studied, tested and verified more to be applicable to all the area.

  • PDF

The Effect of Exposure to Mixed Organic Solvents on Lipid Peroxidation in Ship Building Painters

  • Park, Jun-Ho;Cha, Bong-Suk;Chang, Sei-Jin;Koh, Sang-Baek;Eom, Ae-Yong;Lee, Kang-Myeung;Jung, Min-Ye;Choi, Hong-Soon
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.4
    • /
    • pp.360-365
    • /
    • 2008
  • In the last several years, studies on the association of oxidative stress damage with exposure in the work place have been conducted. Xenobiotics create an imbalance of the homeostasis between oxidant molecules and antioxidant defense. By monitoring oxidative stress biomarkers, information was obtained on damages induced by oxidative stress and the toxicity of xenobiotics. In the present study, a Job Exposure Matrix (JEM) was constructed using the data from the Working Environment Measurement (WEM) of painters in the shipyard industry from the past 3 years to assess the exposure status. Additionally, by measuring the concentration of urinary malondialdehyde (MDA), the effect of lipid peroxidation was examined. The subjects consisted of 68 workers who were exposed to mixed organic solvents in the painting process and 25 non-exposure controls. The exposure indices of the exposure groups were significantly different (sprayer: 0.83, touchup: 0.54, assistant: 0.13, P<0.05). The urinary MDA concentration of the exposure group was 48.60${\pm}$ 39.23 ${\mu}mol$/mol creatinine, which was significantly higher than 18.03${\pm}$16.33 ${\mu}mol$/mol creatinine of the control group (P<0.05). From the multiple regression analysis of urinary MDA, the regression coefficient for exposure grade was statistically significant. In future studies, evaluation of the antioxidant levels of subjects should be performed simultaneously with quantitative exposure measurements.