• Title/Summary/Keyword: Building History

Search Result 1,336, Processing Time 0.027 seconds

Decentralized Control of Building Structures Installed with Semi-active MR Damper (준능동 MR 댐퍼가 설치된 건축 구조물의 분산제어)

  • Youn, Kyung-Jo;Lee, Sang-Hyun;Min, Kyung-Won;Lee, Sung-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.127-132
    • /
    • 2007
  • In this paper, to overcome local damages of structures, an uncertainty of structural model, installing sensors of structures, and economics of building system, decentralized semi-active magnetorheological(MR) damper using the displacement or velocity transferred to the response of floor installed damper is proposed. Relative magnitude between the control force of dampers and the story shear force is difined as design variables and the performance indices response spectra analysis through nonlinear time history analysis excited by seismic loads is performed according to this design variables. And the performance of this decentralized MR damper is compared with previous centralized LQR control algorithm using 3-stories benchmark building structure excited by El Centro (1940, N.S) in order to evaluate the application of building structures.

  • PDF

Emotional Analysis on the Building Background of Chinese History Film 'Hero' (중국역사영화 '영웅'의 건물배경에 대한 감성분석)

  • Yu, Shen;Song, Seung-keun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.291-292
    • /
    • 2018
  • The purpose of this study is to examine the sensitivity of the audience to the background of the building where Chinese historical film 'Hero' is used. In this study, the sensitive vocabulary suitable for the building background was derived through previous research related to sensitivity, and the sensitive analysis was analyzed by questionnaire form. Research result shows that the building background of the movie can have an sensitive impact on the audience and will help to understand Chinese traditional style and culture.

  • PDF

Comparative Study for Fire Protective Materials of Column According to Variance of Lengths (길이변화에 따른 기둥부재의 내화피복 비교연구)

  • Kwon, In-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.118-119
    • /
    • 2014
  • A fire in a steel framed building can decrease a structural stability and cause deformation. And the fire continues the building can be demolished. Therefore, every country requires fire resistance performance of structural elements. In case of column, fire protective thickness derived from a specific fire test using an horizontal furnace is allowed to apply any kinds of sections and lengths of column. However, the lengths and sections of the column in steel framed buildings are various. In this paper, to know the differences of fire performance of steel column according to variance of lengths, a maximum allowable stress, steel surface temperature history, deflection are calculated and the thickness of fire protective material for longer column(4700 mm) need to enforce about 10% more than shorter column (3500 mm).

  • PDF

Basic Study of Distribution Management Model of the Free-Form Concrete Panels (SCM 기법에 의한 비정형 콘크리트 패널의 공급관리 모델 기초연구)

  • Cho, Wonhyun;Na, Youngju;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.115-116
    • /
    • 2016
  • Numerous of free-form buildings come up with external appearances using various types of free-form panels. If the panel types produced, transport and installation order and maintenance history are not properly managed, it is difficult to complete a given project successfully. For free-form building projects that satisfy 5 factors (proper time, place, price, product and quantity), a supply chain management technique is applied for distribution management of free-form concrete panels. In addition, the study listed the whole production process of free-form concrete panels and any necessary information, and suggested a basic model for the management. The study result will be a great help in effective distribution management of free-form panels for free-form building projects.

  • PDF

The Post-Miesian Office Tower and the Global Issue of Its Interpretation

  • Marfella, Giorgio
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.2
    • /
    • pp.127-140
    • /
    • 2018
  • The skylines of many cities worldwide are still defined by the dominant and ubiquitous office blocks of the twentieth century. While there is consensus stating that future tall building typologies should depart substantially from these past models, the inheritance of large and obsolete tall office building stocks presents a problem of global significance. Too old for present corporate models, but too new for gaining public historical importance, the twentieth-century office tower is a typology under threat of extinction. However, the need for a culturally informed strategy of preservation for that generation of tall buildings is seldom advocated. Drawing evidence from the case of Melbourne, Australia, this article presents a methodological pathway to overcome pitfalls of memory and interpretation, which commonly prevent an unbiased assessment of the value and urban contribution of late-twentieth-century skyscrapers.

The Birth and Development of High-Rise Buildings in Japan: Focusing on the Historical Development of Height and Floor Area Ratio Regulations

  • Akihiko Osawa
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.195-201
    • /
    • 2023
  • This paper reviews the history of the birth and development of the skyscraper in Japan, mainly from the perspective of the legal system, and presents the following points: 1) After 1919, building height was limited to 31 m or less, which continued after the war and defined the skyline of Japan's major cities; 2) The 31-meter height limit became a problem during rapid economic growth. With the development of tall building construction technology, the height limit was eliminated, and skyscrapers were born in Japan in the 1960s; 3) Later, the number of skyscrapers increased more rapidly in the post-bubble period after the collapse of the bubble economy in the 2000s than in the boom years of the 1980s, when the floor-area ratio was relaxed for economic uplift and urban renewal. The number of skyscrapers increased rapidly against the backdrop of the deregulation of the floor-area ratio.

Elasto-plastic time history analysis of a 117-story high structure

  • Wu, Xiaohan;Li, Yimiao;Zhang, Yunlei
    • Computers and Concrete
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2017
  • In Chinese Design Codes, for super high-rise buildings with complex structural distribution, which are regarded as code-exceeding buildings, elasto-plastic time history analysis is needed to validate the requirement of "no collapse under rare earthquake". In this paper, a 117-story super high-rise building is discussed. It has a height of 597 m and a height-width ratio of 9.5, which have both exceeded the limitations stipulated by the Chinese Design Codes. Mega columns adopted in this structure have cross section area of about $45m^2$ at the bottom, which is infrequent in practical projects. NosaCAD and Perform-3D, both widely used in nonlinear analyses, were chosen in this study, with which two model were established and analyzed, respectively. Elasto-plastic time history analysis was conducted to look into its seismic behavior, emphasizing on the stress state and deformation abilities under intensive seismic excitation.From the comparisons on the results under rare earthquake obtained from NosaCAD and Perform-3D, the overall responses such as roof displacement, inter story drift, base shear and damage pattern of the whole structure from each software show agreement to an extent. Besides, the deformation of the structure is below the limitation of the Chinese Codes, the time sequence and distribution of damages on core tubes are reasonable, and can dissipate certain inputted energy, which indicates that the structure can meet the requirement of "no collapse under rare earthquake".

Sick Building Syndrome and the Related Factors in Office Workers (일부 대형빌딩 근무자에서 sick building syndrome의 위험요인에 관한 연구)

  • Baik, Jae-Joong;Cho, Soo-Hun;Park, Byung-Joo;Kang, Dae-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.157-170
    • /
    • 1997
  • A cross-sectional study was conducted to investigate the prevalence and risk factors for symptoms associated with sick building syndrome in four office buildings located in Seoul. Information on personal factors, job-related factors, and medical history were collected using self-administered questionnaires modified from the National Institute for Occupational Safety and Health Indoor Air Quality questionnaire in 321 office workers in these buildings. The prevalence of general and irritant symptom groups was higher than the prevalence of dermatologic and respiratory symptom groups. Daily total work time, work time in the office, and work time with video display terminals (VDT) were identified as the risk factors for symptom groups associated with sick building syndrome by multiple linear logistic regression analysis. In conclusion, these results indicated that the symptom prevalence in this study is similar with the results reported from previous studies conducted in other countries and work time and work with VDT are related to sick building syndrome in Korea.

  • PDF

Assessment of pushover-based method to a building with bidirectional setback

  • Fujii, Kenji
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.421-443
    • /
    • 2016
  • When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.

Evaluation of Response Modification Factor of Steel Special Resisting Frame Building Before and After Retrofitted with Buckling Restrained Brace (비좌굴가새의 보강 전과 후의 철골 특수모멘트저항골조 건물의 R계수 평가)

  • Shin, Jiuk;Lee, Kihak;Jo, Yeong Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • This research presents that seismic performance of steel moment resisting frame building designed by past provision(UBC, Uniform Building Code) before and after retrofitted with BRB (Buckling-Restrained Brace) was evaluated using response modification factor (R-factor). In addition, the seismic performance of the retrofitted past building was compared with that specified in current provision. The past building considered two different connections: bilinear connection, which was used by structural engineer for building design, and brittle connection observed in past earthquakes. The nonlinear pushover analysis and time history analysis were performed for the analytical models considered in this study. The R-factor was calculated based on the analytical results. When comparing the R-factor of the current provision with the calculated R-factor, the results were different due to the hysteresis characteristics of the connection types. After retrofitted with BRBs, the past buildings with the bilinear connection were satisfied with the seismic performance of the current provision. However, the past buildings with the brittle connection was significantly different with the R-factor of the current provision.