• Title/Summary/Keyword: Building Height

Search Result 1,085, Processing Time 0.028 seconds

Improvement plan for the standard for calculating the height of the stair railing for Barrier Free (BF) certification system (장애물 없는 생활환경(BF) 인증제도 계단 난간 높이 산정기준 개선안)

  • Lee, Sang-Soo;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.218-219
    • /
    • 2022
  • Among the Barrier Free (BF) certification evaluation items for public facilities, at which position the standard for the effective height of the stair railing handle should be calculated is not clearly determined. Because of this, not only the evaluation standards of the certification authority and the evaluation committee are different, but disputes are occurring between the ordering organization, the design company, and the construction company. Therefore, the stair railing installation standard laws for public facilities were analyzed and through a case study of institutions that obtained the BF certification, problems were analyzed. The results of problem analysis reveal the following. 1) The standards of the Ministry of Health and Welfare and the Ministry of Land, Infrastructure, and Transport were different. 2) The effective height calculation standard was ambiguous, and disputes occurred frequently. To solve this problem, we proposed improvement plans for calculating the height of the stair railing that can comply with laws while ensuring safety.

  • PDF

Characteristics of wind-Induced Coupled Motion of Tapered and Setback Tall Buildings (비정형 초고층 건물의 바람에 의한 편심응답 특성)

  • Kim, Yong-Chul;Kanda, Jun;Tamura, Yukio
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.1
    • /
    • pp.79-86
    • /
    • 2013
  • For most of recent tall buildings, one characteristic is that their building shapes vary with height such as taper and setback, and this implies that the distribution of their structural components may also vary with height. Because of these structural variations, although the sectional shapes of these buildings are symmetric, it is difficult to say whether or not they are structurally symmetric. The acceleration responses of structurally asymmetric tall buildings are larger than those of non-eccentric buildings, thus raising the possibility of problems during strong winds and typhoons. This paper describes wind tunnel tests carried out using building models with height variations and acceleration response analyses, and discusses the resulting response characteristics. For tapered and setback buildings, although the across-wind accelerations are larger than those of a square building, the total root-mean-square accelerations remain small because of smaller along-wind and torsional rms accelerations. And it was found that the effects of statistical couplings between along-wind force and other two forces are negligible.

Towards guidelines for design of loose-laid roof pavers for wind uplift

  • Mooneghi, Maryam Asghari;Irwin, Peter;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.22 no.2
    • /
    • pp.133-160
    • /
    • 2016
  • Hurricanes are among the most costly natural hazards to impact buildings in coastal regions. Building roofs are designed using the wind load provisions of building codes and standards and, in the case of large buildings, wind tunnel tests. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. The objective of this paper is to develop simple guidance in code format for design of loose-laid roof pavers. Large-scale experiments were performed to investigate the wind loading on concrete roof pavers on the flat roof of a low-rise building in Wall of Wind, a large-scale hurricane testing facility at Florida International University. They included wind blow-off tests and pressure measurements on the top and bottom surfaces of pavers. Based on the experimental results simplified guidelines are developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as American Society of Civil Engineering (ASCE) 7-10 standard's pressure coefficients for components and cladding. The effects of the pavers' edge-gap to spacer height ratio and parapet height to building height ratio are included in the guidelines as adjustment factors.

A Study on the Wind Pressure Coefficients of Flat-type Apartment Complexes Considering Building Layout and Aspect Ratio (판상형 공동주택의 동 배치 및 종횡비에 따른 풍압계수 특성에 관한 연구)

  • Yoon, Seong-Hoon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.153-159
    • /
    • 2021
  • In this study, basic data that can be referenced for ventilation modeling was presented by analyzing the characteristics of wind pressure coefficients(Cp) according to wind direction angles under conditions of different building layouts and aspect ratios through CFD (Computational Fluid Dynamics) analysis for flat-type apartment complexes. In the case of a wind direction angle of 0°, Cp distribution in the form of an inverted S-shape was shown on the front of the building located on the windward side. And Cp corresponding to the lowest floor, the uppermost floor, and the two inflection points showed relatively close values regardless of the height of the building. The inflection point of the low-rise part was formed at a height of about 11m, and the height of the high-rise part could be calculated through a trend formula proportional to the height of the building. It was confirmed that the averaged Cp value can be applied in most conditions except for the wind direction angle of 45 degrees.

EXTRACTING OUTLINE AND ESTIMATING HEIGHT OF LAND FEATURES USING LIDAR DATA

  • Lee, Woo-Kyun;Song, Chul-Chul
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.181-183
    • /
    • 2006
  • Digital topographic map in Korea contains layers of spatial and attribute data for 8 land features such as railroads, watercourses, roads, buildings and etc. Some of the layers such as building and forest don't include any information about height, which can be just prepared by interpretation of remote sensed data or field survey. LiDAR(Light Detection And Ranging) data using active pulse and digital camera provides data about height and form of land features. LiDAR data can be used not only to extract the outline of land features but also to estimate the height. This study presents technical availability for extraction and estimation of land feature's outline and height using LiDAR data which composes of natural and artificial land features, and digital aerial photograph which was taken simultaneously with the LiDAR. The estimated location, outline and height of land features were compared with the field survey data, and we could find that LiDAR data and digital aerial photograph can be a useful source for estimating the height of land features as well as extracting the outline.

  • PDF

Underground Parking Lot by ANI Girder(ANgle Integrated Girder) and HCS (ANI Girder(앵글 및 래티스 철근으로 구성된 강조립보)와 HCS(Hollow Core Slab)를 활용한 지하주차장)

  • Choi, Ik-Jun;Jeon, Byong-Kap;Yom, Kyong-Soo;Choi, Sung-Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.101-102
    • /
    • 2016
  • Through the story height reducing method, cost saving can be implemented in many aspects. Recently, as one of PC floor system, HCS(Hollow Core Slab) has been applied in many project, and it is proved that it is excellent in productivity, economic efficiency, and workability as well. We developed a new composite beam(ANI Girder) which can be associated with HCS and reinforced with a truss-shape rebar and angle. As a result of actual application on underground parking building with HCS, it is confirmed that this system is effective in workability and story height reducing.

  • PDF

the height-wise distribution of lateral seismic forces considering the contribution of the higher modes (고차모드 효과를 고려한 층 지진하중 분배)

  • 황준호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.273-280
    • /
    • 1999
  • The base shear and the veritcal distribution of shears along the height of a building are two fundamental measures that define the design seismic load. But the method specified in Korean building code does not give an appropriate distribution for buildings of tall or longer period because it roughly account for the contributions of the higher modes. several methods to give a better distribution of seismic forces have been proposed. But they have not been introduced into the seismic codes yet probably because they cannot solve all the above-mentioned problems. This paper deals with the distribution of lateral seismic forces along the height of a building to account for the contribution of the higher modes. After reviewing some existing distributions in seismic codes and literatures moment-resisting frames with various stories were studied by modal analysis for a wide range of fundamental period and the stiffness ratio of the buiding. As a result of the analysis a new expression for the distribution of seismic forces is proposed and compared with those of some codes and dynamic analysis.

  • PDF

Variation Characteristics of Stiffness and Impact Resistance under Conastruction Height of Gypsum Board Wall (석고보드 벽체의 시공높이에 따른 수평하중저항성 및 내충격성 변동 특성)

  • Song, Jung Hyeon;Kim, Ki Jun;An, Hong Jin;Shin, Yun Ho;Ji, Suk Won;Choi, Soo Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.184-185
    • /
    • 2014
  • The purpose of this study is to experimentally evaluate the variation characteristics of stiffness and impact resistance under the construction height of gypsum board wall at the actual construction site. The method suggested in previous study was applied on the test method of horizontal load resistance and impact resistance. As a result of horizontal load resistance test, when the wall height is 2,400 mm, the maximum displacement is 13.6 mm and residual deformation is 0.5 mm, and when the wall height is 3,000 mm, the maximum displacement is 31.3 mm and the residual displacement is 6.8 mm. As a result of impact resistance test, the residual deformation of each specimen at 20 cm of fall height were 1.02 mm and 0.08 mm, respectively, the residual deformation at 40 cm of fall height were 1.58 mm and 0.35 mm, respectively, and the residual deformation at 60 cm of fall height were 2.23 mm and 2.48 mm, respectively.

  • PDF

Investigation of receiving position in the measurement method for floor impact sound in a testing building (표준시험동 바닥충격음 측정위치에 대한 고찰)

  • Lee, Sin-Young;Yoo, Seung-Yup;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

Analyzing the Relationship between the Spatial Configuration of Urban Streets and Air Quality (도시가로의 형태요소와 대기질과의 관계 연구)

  • Chu, Junghyun;Oh, Kyushik;Jeong, Yeun-Woo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.73-82
    • /
    • 2009
  • The traffic volume of Seoul is extremely high in comparison to other major cities in Korea, and the result has been harmful physical and mental exposure to pollution by Seoulites on a regular basis. The street air pollution is more important than the others, because the air pollution generated by street traffic directly impacts the health of nearby pedestrians. This problem requires urgent attention and resolution. Among the factors creating the air pollution originating from the street, is the configuration of streets, which have emerged as the most significant because it is related to air and pollutant dispersion. Therefore, this study was conducted under the assumption that street form affects the air quality. Study sites were classified by street characteristics, and air quality was analyzed in each class. Then the OSPM (Operational Street Pollution Model) was employed to simulate the relationship between street configuration and air quality of streets within the old city center and new city center in Seoul. After that this study analyzed the correlation between air pollution and the spatial configuration of urban streets (ex. street width, building height, building density, etc.) to determine their contributions to air pollution. The outcome of this study is as follows : First, the result that was derived from the correlation analysis between street configuration and air quality hewed that the air pollution of the street is influenced by the average height of building, width of the roads as well as traffic volume. On the roadside, the concentration level of $NO_2$ is mainly affected by the average height of building and the deviation of building height along the street and CO is affected by street width. The outcome of this study can be used as a basis for more sound urban design policies, and the promotion of desirable street environments for pedestrians.