Abstract
In this study, basic data that can be referenced for ventilation modeling was presented by analyzing the characteristics of wind pressure coefficients(Cp) according to wind direction angles under conditions of different building layouts and aspect ratios through CFD (Computational Fluid Dynamics) analysis for flat-type apartment complexes. In the case of a wind direction angle of 0°, Cp distribution in the form of an inverted S-shape was shown on the front of the building located on the windward side. And Cp corresponding to the lowest floor, the uppermost floor, and the two inflection points showed relatively close values regardless of the height of the building. The inflection point of the low-rise part was formed at a height of about 11m, and the height of the high-rise part could be calculated through a trend formula proportional to the height of the building. It was confirmed that the averaged Cp value can be applied in most conditions except for the wind direction angle of 45 degrees.
Keywords
Wind pressure coefficient; Apartment complexes; Building layout; Aspect ratio; Wind direction angle; CFD(Computational Fluid Dynamics);
Citations & Related Records
연도 인용수 순위
  • Reference
1 S. H. Kim, S. W. Yoon & S. D. Kim. (1995) A Study of the Wind Pressure Coefficient for Tall Buildings, Proceeding of Architectural Institute of Korea, 15(2), 427-430.
2 H. Yoon, S. T. No & K. S. Kim. (2009). A Study about Natural Ventilation Analysis Methods for Apartment Buildings Using CFD, Journal of the Architectural Institute of Korea (Planning & Design), 25(6), 221-228.
3 J. Burnett, M. Bojic & F. Yik. (2005). Wind-induced Pressure at External Surfaces of A High-rise Residential Building in Hong Kong, Building and Environment, 40, 765-777.   DOI
4 J. I. Lee & J. O. Yoon. (2014). Simulations of Wind Pressure Coefficient at Windward Wall and Leeward Wall of Apartment Buildings, Proceeding of Architectural Institute of Korea (Spring Conference), 34(1), 239-240.
5 S. H. Suh, K. Y. Lee, S. S. Yoo & H. W. Roh. (1995). Determination of Wind Pressure Coefficients around Prismatic Structures with Different Aspect Ratios, Journal of Air Conditioning and Refrigeration Engineering, 7(1), 52-62.
6 J. S. Choi,, E. J. Kim & S. H. Yoon. (2019). A Study on the Comparison of Wind Pressure Coefficient and Natural Ventilation Performance Accorcing to the Layout of Apartment Complex, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 13(5), 315-324.
7 Ministry of Land (2020). Infrastructure and Transport, Regulations for Equipment Standard of Building, Attached Table 1-3.
8 J. S. Choi, E. J. Kim & S. H. Yoon. (2021). A Study on the Wind Pressure Coefficients and Natural Ventilation Performance of Apartment Complexes Considering Wind Direction and Building Layout, Journal of the Korean Solar Energy Society, 41(2), 39-49.
9 D. S. Shin, J. H. Park, B. M. Kang, E. M. Kim, H. J. Lim & J. Y. Lee. (2016). A Study of Wind Pressure Distribution for A Rectangular Building Using CFD, Korean Journal of Air-Conditioning and Refrigeration Engineering, 28(1), 1-6.   DOI
10 Ministry of Land (2020). Infrastructure and Transport, Regulations for Equipment Standard of Building, Article 11.
11 M. Orme, M.W. Liddament & A. Wilson. (1998) Numerical Data for Air Infiltration & Natural Ventilation Calculations, Technical Note AIVC 44, 82-87.
12 M. Orme & N. Leksmono. (2002) Ventilation Modeling Data Guide, AIVC Guide 5, 63-66.
13 D. Mu, N. Gao & T. Zhu. (2016). Wind Tunnel tests of Inter-flat Pollutant Transmission Characteristics in A Rectangular Multi-storey Residential Building, Part A : Effect of Wind Direction, Building and Environment, 108, 159-170.   DOI
14 D. Mu, C. Shu, N. Gao & T. Zhu. (2017). Wind Tunnel tests of Inter-flat Pollutant Transmission Characteristics in A Rectangular Multi-storey Residential Building, Part B : Effect of Source Location, Building and Environment, 114, 281-292.   DOI
15 W. J. Jo & J. Y. Sohn. (2007). Distribution Characteristic of Seasonal Wind Pressure of an Apartment Complex by Wind Tunnel Test. Journal of the Architectural Institute of Korea (Planning & Design), 23(8), 237-245.