• Title/Summary/Keyword: Building External

Search Result 824, Processing Time 0.029 seconds

A Study on Designing a Proper External Shading Device to Diminish the Cooling Load of a Transparent Glazing Office Building (투명 유리 사무소 건물의 냉방부하 감소를 위한 적정 외부차양 배치에 관한연구)

  • Yim, Sang-Joon;Seo, Hye-Soo;Kim, Byung-Seon
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Modem architecture represent a great capitalistic, polishing, high-technology image to the public by design. As a result, glass architecture which show 'transmittance' in desinging play a leading part, consequently a role of machine is increasing in controlling an internal environment of building. These movement look like assisting an universal standard building disregarding a each nation's climate peculiarity, if glass building is applied by a proper external shading device. the shading device has a great effect on the reduction of cooling load energy, this research to propose the proper designing scheme of the fixed external shading device. The effect of proper external shading device on the cooling load is evaluated by the numeric simulation.

Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change (기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구)

  • Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

A study on the Aluminium Beam Methods for Building a Stone Finished Envelope (석재 외피 시공을 위한 알루미늄 빔 지지공법 연구)

  • Kim, Jang-Ook;Lee, Young-Lae;Hong, Seong-Wook;Doh, Sun-Boong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.235-242
    • /
    • 2012
  • In recently constructed building, It has become fashionable again that the heavy external skin system such as a Stone Finished Envelope. There are Squared Steel Pipe Methods, C-Shaped Steel Pipe Methods, and Aluminum Beam Methods in the structure of a heavy external skin system. The Aluminum Beam Methods is often misunderstood as a Plane Truss Structure, but this method is not appropriate to be called to a truss structure but a beam methods. The Aluminum Beam Methods is the most Eco-friendly methods in terms of Quality assurance, Efficiency, Safety, Construction period, Durability, and Recyclability. And this Methods is also very appropriate in considering the point of Energy conservation, Waste reduction, Long-life architecture, Replacement parts, Environmental protection, Public efficiency, and Building demolition.

  • PDF

Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance (준불연 외단열시스템의 역학적 특성에 관한 연구)

  • Choi, Ki-Sun;Ha, Soo-Kyung;Oh, Keun-Yeong;Park, Keum-Sung;Ryu, Hwa-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.507-518
    • /
    • 2021
  • The application of an adhesive calcium carbonate-based hybrid insulation board with quasi-combustibility in the external thermal insulation composite system(ETICS) ensures effective thermal performance and fire safety. This study aimed to conduct a mechanical test of the quasi-non-combustible hybrid insulation board as well as its constituent materials to obtain the basic data for the structural design of the adhesive ETICS. Test specimens were fabricated based on domestic and foreign test standards to examine and evaluate their tensile, compressive, flexural, and shear strengths. The strength characteristics of the quasi-non-combustible hybrid insulation board were identified from the test results, which verified that the minimum required physical properties suggested by the current KS M ISO 4898 were met. Furthermore, the quasi-non-combustible ETICS used in this study was found to be suitable for use as an external insulation system for walls unless subjected to continuous gravity load, such as a heavy exterior finish.

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D.;Holmes, John D.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.361-376
    • /
    • 2008
  • This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

Other Changes in Bond Strength due to External Insulation Method (외단열 고정 방법에 따른 부착강도 변화)

  • Kim, Tae-Jun;Park, Wan-Goo;Park, Jin-Sang;Oh, Jung-Hwan;Bae, Ki-Sun;Oh, Sang Geun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.132-133
    • /
    • 2013
  • External Insulation Method is to place the insulation on the outside of concrete. External Insulation Method is better than Internal Insulation Method to the protection of structure. However, The phenomenon that External Insulation falling from the structure occurs frequently. Apply method of External Insulation is divided Wet Construction, Dry Construction and Wet & Dry Construction. The purpose of this study is to test Bonding Strength of External Insuation. Furthermore, on the basis of this study, External Insulation Method determines the effective development will be made.

  • PDF

A Study on the Characteristics of Daylighting Environment in Classroom of an School Building Due to the External Shading Devices (학교 건물에서 외부 차양 장치 유형에 따른 일반교실 내 빛환경 특성에 관한 연구)

  • Lim, Jae-Han;Jung, Jin-Ju;Lee, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.2
    • /
    • pp.4-15
    • /
    • 2008
  • The purpose of this study was to evaluate the characteristics of daylighting environment in classroom of an school building due to the external shading devices such as fixed louvers, light shelves and exterior venetian blinds. In this study, we have made a field research with regard to the facade design in classroom of an school building. And we have made a classification of external shading devices considering the design parameters. Finally, through RADIANCE simulation, we have calculated the spatial distribution of illuminance, uniformity ratio of illuminance and daylight factors. The results of this study will provide the building designer with the basic daylighting performance data at early design stages.

The effects of topography on local wind-induced pressures of a medium-rise building

  • Hitchcock, P.A.;Kwok, K.C.S.;Wong, K.S.;Shum, K.M.
    • Wind and Structures
    • /
    • v.13 no.5
    • /
    • pp.433-449
    • /
    • 2010
  • Wind tunnel model tests were conducted for a residential apartment block located within the complex terrain of The Hong Kong University of Science and Technology (HKUST). The test building is typical of medium-rise residential buildings in Hong Kong. The model study was conducted using modelling techniques and assumptions that are commonly used to predict design wind loads and pressures for buildings sited in regions of significant topography. Results for the building model with and without the surrounding topography were compared to investigate the effects of far-field and near-field topography on wind characteristics at the test building site and wind-induced external pressure coefficients at key locations on the building facade. The study also compared the wind tunnel test results to topographic multipliers and external pressure coefficients determined from nine international design standards. Differences between the external pressure coefficients stipulated in the various standards will be exacerbated when they are combined with the respective topographic multipliers.

Comparative Study on the Standards of Internal and External Materials of Each Country for Fire Safety of Buildings (건축물의 화재안전설계를 위한 각국의 내·외장재 기준 비교 연구)

  • Huh, Ye-Rim;Kim, Yun-seong;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.170-171
    • /
    • 2021
  • In Korea, the concentration of cities has led to the high-rise and deep-rise of buildings. In the case of such high-rise buildings, there is a high risk of fire, and the number of internal fires expanding to the outside continues to increase. The Korean Building Act continues to change the ban on combustible exterior materials, and combustible exterior materials are currently not available for buildings with three stories or more than 9 meters, and detailed test standards for finishing materials are also strengthened after the Ulsan residential and commercial fires in 2020. However, the path of fire in the actual building is through a series of processes in which the fire in the compartment grows internally and expands through openings supplied with ventilation factors. Therefore, other than just external materials, design criteria for embedded materials also need to be established. The purpose of this study is to compare standards for internal and external materials at home and abroad and to secure basic data for fire safety design of buildings based on them.

  • PDF

Shear Performance Evaluation of Composite Thermal Insulation with Quasi-Non-Combustible according to Adhesive Type (부착 유형에 따른 준불연 복합단열판 전단성능평가)

  • Choi, Ki-Sun;Oh, Keunyeong;Park, Keum-Sung;Ha, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.507-518
    • /
    • 2022
  • The purpose of this research is to obtain experimental data for developing a structural design of an external insulation system by evaluating the shear performance of a composite insulation system according to the adhesive type. The shear performance of the composite insulation system was experimentally evaluated by considering a simultaneous placement method, full and spot/edge coverage using adhesive mortar. As a result of the test, the shear strength of simultaneous placement and full coverage method was almost similar, the spot/edge coverage method was about 80% of them. Also, the simultaneous placement method is considered to be constructively advantageous when applied as an external insulation system to a high-rise building compared to using an adhesive mortar.