Abstract
The purpose of this research is to obtain experimental data for developing a structural design of an external insulation system by evaluating the shear performance of a composite insulation system according to the adhesive type. The shear performance of the composite insulation system was experimentally evaluated by considering a simultaneous placement method, full and spot/edge coverage using adhesive mortar. As a result of the test, the shear strength of simultaneous placement and full coverage method was almost similar, the spot/edge coverage method was about 80% of them. Also, the simultaneous placement method is considered to be constructively advantageous when applied as an external insulation system to a high-rise building compared to using an adhesive mortar.
Keywords
quasi-non-combustible; composite thermal insulation; shear performance evaluation; adhesion type; external thermal insulation system;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 ETAG 004. External thermal insulation composite systems(ETICS) with rendering. European Organization for Technical Assessment(EOTA); 2013. p. 28-64.
2 Kim TJ, Park WG, Park JS, Oh JW, Bae KS, Oh SG. Other changes in bond strength due to external insulation method. Proceeding of Korean Institute of Building Construction; 2013 Nov 15; Incheon, Korea. Seoul (Korea): the Korean Institute of Building Construction; 2013. p. 132-3.
3 Jang SJ, Oh TS, You YC, Kim HR, Yun HD. Effects of corrugated GFRP shear connector width and pitch on in-plane shear behavior of insulated concrete sandwich wall panels (CSWP). Journal of the Korea Concrete Institute. 2014 Aug;26(4):421-8. http://dx.doi.org/10.4334/JKCI.2014.26.4.421   DOI
4 Jang SJ, Kim HR, You YC, Yun HD. In-plane shear responses of insulated concrete sandwich panels (CSWP) with corrugated glass fiber-reinforced polymer (GFRP) shear connectors. Journal of the Architectural Institute of Korea Structure & Construction. 2014 Mar;30(3):3-10. https://doi.org/10.5659/JAIK_SC.2014.30.3.003   DOI
5 Jang SJ, You YC, Kim HR, Yun HD. Effect of glass fiber-reinforced polymer (GFRP) shear connector's shape on inplane shear strength of insulated concrete sandwich panels. Journal of the Korea Institute for Structural Maintenance and Inspection. 2013 Jul;17(4):9-17. http://dx.doi.org/10.11112/jksmi.2013.17.4.009   DOI
6 Kim WH, Kang EH, Yoon JH. Energy performance evaluation study on the thermal bridge blocking external insulatior system for green remodeling. Proceeding of Korean Institute of Building Construction; 2011 Nov 18; Suwon, Korea. Seoul (Korea): the Korean Institute of Building Construction; 2011. p. 234-5.
7 Hong GP, Kang JY, Kim HG. Thermal performance of developed cladding systems on multi-family residential buildings. Proceeding of Korean Institute of Building Construction; 2018 May 16-18; Jeju, Korea. Seoul (Korea): the Korean Institute of Building Construction; 2018. p. 267-8.
8 Choi KS, Ha SK, Oh KY, Park KS, Ryu HS. Mechanical properties of external thermal insulation composite system with quasi-non-combustible performance. Journal of the Korea Institute of Building Construction. 2021 Oct;21(5):507-18. https://doi.org/10.5345/JKIBC.2021.21.5.507   DOI
9 Bae MJ, Kang JS. Improving on the fire safety of EPS foamed plastic insulation materials using expanded graphite. Journal of the Architectural Institute of Korea. 2021 May;37(5):181-9. https://doi.org/10.5659/JAIK.2021.37.5.181   DOI
10 AC422. Acceptance criteria for semi-continuous fiber-reinforced grid connectors used in combination with rigid insulation in concrete sandwich panel construction. ICC Evaluation Service; 2019. p. 1-10.
11 Naito CJ, Hoemanm JM, Bewick BT, Hammons MI. Evaluation of shear tie connectors for use in insulated concrete sandwich panels. USA: Air Force Research Laboratory; 2009 Dec. p. 1-31. Report No. AFRL-RX-TY-TR-2009-4600.
12 ASTM E488. Standard test methods for strength of anchors in concrete elements. American Society for Testing and Materials; 2018. p. 1-21.
13 Tomlinson DG, Teixeira N, Fam A. New shear connector design for insulated concrete sandwich panels using basalt fiber-reinforced polymer bars. Journal of Composites for Construction. 2016 Aug;20(4):1-13. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000662   DOI
14 LHCS 41 42 00 15. Exterior insulation system. Korean Construction Specification; 2020. p. 1-19.
15 KS F 2405. Standard test method for compressive strength of concrete. Korean Standards Association; 2017. p. 1-7.
16 Ryu SR, Cheong CH, Suh HS. A study on the bond strength between exterior insulation board and cast-in-place concrete. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems. 2016 Dec;10(6):437-42.
17 Park WG, Park JS, Song JY, Oh SG. A research on enactment plan of standard of bonding strength in bonding part of external insulation method. Journal of the Architectural Institute of Korea Structure & Construction. 2013 Jan;29(1):83-90. https://doi.org/10.5659/JAIK_SC.2013.29.1.83   DOI