• 제목/요약/키워드: Building Energy Simulation

검색결과 684건 처리시간 0.023초

수직 외벽면 적용 BIPV의 Mock-up 실험연구 (A Study on the Mock-up test for applying BIPV in the external curtain Wall)

  • 이한명;오민석;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.110-118
    • /
    • 2009
  • This research is an experimental study on BIPV Power performance of See-through a-si and Light-through applying external curtain wall. In case of See-through a-si Photovoltaic, appropriateness of facade applying standard($950\;{\times}\;980mm$) large($950\;{\times}\;1960mm$)area photovoltaic was examined. Transparent performance was also investigated through Power simulation according to angles and seasons of See-through a-si and Light-through Photovoltaic so that Power output was surveyed with using designed and manufactured Mock-up. When comparing See-through a-si to Light-through Photovoltaic for simulation Power output on angles based on full south aspect, which the result was that See-through a-si Power output according to Light-through Power output was the highest of 65.5% when applying a 90 degree angle. Monthly accumulated average Power output during winter seasons (December, January and February) applying a vertical plane on full south aspect was analyzed, which results in 66.37W/h of See-through a-si and 139.1 W/h of Light-through. See-through a-si Power output showed 47.7% in comparison with Light-through transparent. Also monthly, hourly average Power efficiency according to solar radiation during winter seasons (December, January and February) was that 4.7% of See-Through a-si and 9.8% of Light-through.

저심도 지중 수소저장시설에서의 수소가스 누출에 따른 불포화 지반의 수리-역학적 거동 예측 연구 (Prediction of Hydrodynamic Behavior of Unsaturated Ground Due to Hydrogen Gas Leakage in a Low-depth Underground Hydrogen Storage Facility)

  • 고규현;전준서;김영석;김희원;최현준
    • 한국지반공학회논문집
    • /
    • 제38권11호
    • /
    • pp.107-118
    • /
    • 2022
  • 최근 증가하는 수소에너지 수요에 대응할 수 있는 안정적인 수소 저장 기술에 대한 사회적 니즈가 증가하고 있으며, 이 중 지중수소저장은 대규모 수소 저장이 가능하여 가장 경제적이고 합리적인 저장 방식으로 인식되고 있다. 국내의 경우, 인공적인 방호구조물을 활용한 저심도 수소 저장 방식을 고려하고 있는데, 이와 관련된 안전기준 확립 및 지반 안정성 평가가 중요해지고 있다. 본 연구에서는 저심도 지중 수소저장시설에서의 수소가스 누출 시 발생할 수 있는 지반의 수리역학적 거동을 복합해석 모델을 통해 평가하였다. 벤치마크 실험을 통하여 해석 모델의 예측 신뢰성을 검증한 후, 메타모델을 활용한 매개변수연구를 수행하여 고압수소가스의 지반 침투에 따른 지표면 융기현상에 대한 영향 인자들의 민감도에 대해 평가하였다. 분석결과, 수소가스의 지반누출에 따른 지표변위 변화에 대한 민감도는 지반의 탄성계수가 가장 큰 것으로 확인되었다. 이러한 연구결과는 향후 수소가스 누출뿐만 아니라 수소가스 폭발에 대한 지반 복합해석 평가 시 유용한 기초자료로 활용될 것이다.

혼합공조와 중앙공조 시스템의 경제성 분석 및 비교 (Economic Analysis and Comparison between Hybrid and Central Air Conditioning System)

  • 이윤종;김찬중;문제명;김철우;서형준;김경록;신행조;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.334-339
    • /
    • 2007
  • This paper is concerned with economic analysis and comparison between hybrid and central air conditioning system by TRNSYS simulation and Life Cycle Cost(LCC) analysis. Hybrid air conditioning system that is using VAV for interior zone and system air-conditioner for perimeter zone is installed in building A. Central air conditioning system is composed of VAV and convector. The simulation was carried out in mode temperature level control using TRNSYS 16. From the result of simulation and LCC analysis, hybrid air conditioning system was better than central air conditioning system in initial cost and energy consumption.

  • PDF

베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석 (Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles)

  • 신화영;김곤;김정태
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

선운동량 보존의 법칙을 활용한 감충지주의 충돌거동 (Impact Performance of Crashworthy Post Utilizing Conservation of Linear Momentum)

  • 고만기;김기동;노민형;윤덕근
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8966-8976
    • /
    • 2015
  • 도로변에 노출된 지주는 충돌 시 탑승자 안전에 치명적인 위험물이다. 노출된 지주에 충돌하는 차량의 탑승자 안전을 도모하기 위하여 차량과 지주가 소성충돌로 일체화 되는동안 충돌차량의 선형운동량이 지주로 전달되어 충돌에너지의 일부가 1차적으로 소산되고 감소된 속도로 이동하는 지주의 베이스가 기초에 매입된 충격에너지 흡수용 모듈을 충격하여 변형시킴으로써 나머지 에너지가 소산되는 감충지주를 개발하였다. LS-DYNA프로그램을 이용한 충돌 해석을 실시하여 강결된 지주의 문제점을 보이고 개발 단계별 감충지주와 차량의 거동을 분석하여 최종 설계된 감충지주가 노출상태에서 0.9ton-80km/h의 속도로 정면충돌하는 경우에 안전하게 대응할 수 있음을 확인하였다.

하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가 (Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer)

  • 김상진;김은수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

건물용 연료전지 복합배기구조 안전 실증평가 (An Empirical Evaluation of Safety of the Common Vent Structure for Stationary Fuel Cell Systems)

  • 이은경;이정운;문종삼;이성희;신동훈
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.596-605
    • /
    • 2018
  • Interest in hydrogen, as an energy carrier, has been growing to solve the problems on shortage of fossile fuels and greenhouse gas. According to the standard KGS FU 551 for stationary fuel cell installation, the fuel cell system could be connected up to two common exhausts to one floor. depending on the required power for building or the installation environment in buildings, multiple fuel cell systems could be installed. Afterwards the number of perforations and flues could be decided. Hence, economic efficiency in significantly determined with respect to installation area and the number of fuel cell systems. In addition, the complexity of common vent structure for stationary fuel cell systems could be changed. In this paper, Verification experiments were conducted by connecting the common exhaust system to the fuel cell simulation system and the actual fuel cell system. Humidity and temperature were changed at ON/OFF, but no factors were found to affect performance or system malfunction. Exhaust emissions were also measured to obtain optimized values. We intend to expand the diffusion of stationary fuel cells by verifying safety of common exhaust structure.

CFD를 이용한 열회수형 환기장치 운전에 따른 혹한기 공동주택의 실내 열환경 검토 (A Study of the Indoor Thermal Environment in Apartment Buildings in Freezing Weather Operation of Heat Recovery Ventilator by CFD Simulation)

  • 김창연;박종일;김동규;신병환;금종수
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.293-299
    • /
    • 2015
  • In Korea, it is the law that an apartment building which consists of over 100 households must have a ventilation system installed, either natural or mechanical. The heat recovery ventilator (HRV) is great way to reduce energy consumption. In this research we confirmed that based on site's construction plan and existing diffuser form, performed purpose CFD which simulates operation in temperatures below $-5^{\circ}C$ to circumstances of installation of an HRV in an apartment. As a result of this research we found that when the diffuser's aperture area was adjusted, the distribution of air temperature and residence time of air was more equally distributed and air temperature was higher, compared to when the diffuser has an identical aperture area. We also found that we are able to increase even more air temperature and air distribution of air temperature and residence time of air was even more equally distributed when run in parallel with a splitter damper.

이중 바닥 온돌 시스템의 응용에 관한 이론적 분석 (Theoretical Analysis on the Applications of the Double-Floor Ondol System)

  • 최원기;이강영;이현근;서승직
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.355-363
    • /
    • 2007
  • The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.