• Title/Summary/Keyword: Building Energy Reduction

Search Result 462, Processing Time 0.029 seconds

A study on the Energy Consumption and the Greenhouse gas Emission intensity of Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Ju-Young;Kim, Yu-Lan;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to provide a fundamental data for reducing energy consumption and greenhouse gas emission of detached houses by investigating the energy consumption characteristic of detached houses in Daegu. Although the ratio of the detached houses decreases, the detached houses are common dwelling form next to apartments. Nevertheless the study about the energy consumption of detached houses has been insufficient compared apartments. There is a necessity which will investigate the energy consumption characteristic of detached houses. Because that with the building quality which is various form is different from apartments. This study investigate construction and equipment conditions and analyzing effective factors on energy consumption of detached houses. And this study draw up the energy consumption unit and emission factors unit for greenhouse gas of detached houses. This study represent a basic report for energy consumption reduction and helps effective use of energy.

  • PDF

Heating and Cooling Energy Demand Evaluating of Standard Houses According to Layer Component of Masonry, Concrete and Wood Frame Using PHPP (PHPP를 활용한 조적, 콘크리트, 목조 레이어 구성별 표준주택 냉·난방 에너지 요구량 평가)

  • Kang, Yujin;Lee, Junhee;Lee, Hwayoung;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • A lot of the energy are consumed on heating and cooling in buildings. The buildings need to minimize the heating and cooling loads for $CO_2$ emissions and energy consumption reduction. In recently, also demand of detached houses were increase while the residential culture was changed. The structure of the domestic detached houses can be divided into masonry, concrete, wood frame houses. Therefore, in this study, the heating and cooling load and energy demand were analyzed on the equal area detached house consisting of three structural methods (Masonry, Concrete, Wood frame). Layer of wall, roof, and floor were composited by structure. Thermal transmittance (U-value) of each layer was using the PHPP calculation for considering stud, such as the wood frame wall. In addition, the case of without considering for studs in wood frame wall (Non-studs) was analyzed in order to compare the difference between studs or not. Analysis was performed using self-developed heating and cooling load calculation program (CHLC) based excel and ECO2. The results of cooling and heating load and energy demand showed the highest values in the wood frame structure, and the concrete structure were confirmed to maintain a high value secondly. Two structure were determined to be disadvantageous on the energy consumption. Consequently, the masonry structure have an advantage over the other structure under the identical conditions. It was determined that if the except for thermal bridges due to the studs in the wood frame structure, it can be reduced the energy consumption.

Energy-factor-based damage-control evaluation of steel MRF systems with fuses

  • Ke, Ke;Yam, Michael C.H.
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.589-611
    • /
    • 2016
  • The primary objectives of this research are to investigate the energy factor response of steel moment resisting frame (MRF) systems equipped with fuses subject to ground motions and to develop an energy-based evaluation approach for evaluating the damage-control behavior of the system. First, the energy factor of steel MRF systems with fuses below the resilience threshold is derived utilizing the energy balance equation considering bilinear oscillators with significant post-yielding stiffness ratio, and the effect of structural nonlinearity on the energy factor is investigated by conducting a parametric study covering a wide range of parameters. A practical transformation approach is also proposed to associate the energy factor of steel MRF systems with fuses with classic design spectra based on elasto-plastic systems. Then, the energy balance is extended to structural systems, and an energy-based procedure for damage-control evaluation is proposed and a damage-control index is also derived. The approach is then applied to two types of steel MRF systems with fuses to explore the applicability for quantifying the damage-control behavior. The rationality of the proposed approach and the accuracy for identifying the damage-control behavior are demonstrated by nonlinear static analyses and incremental dynamic analyses utilizing prototype structures.

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

Temperature Reduction with the Location of Window in a Turbine Building of Power Plant (발전소 터빈건물의 창문 위치에 따른 온도저감)

  • Ha, J.S.;Kim, T.K.;Jeong, K.H.
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.207-213
    • /
    • 2016
  • In this study, a thermal flow analysis was performed using the commercial code, ANSYS-FLUENT to reduce room temperature in a turbine building of power plant. The selected control volume of the operating floor and deaerator floor for the turbine building was respectively modelled. The skylight windows at the deaerator floor were employed for ventilation windows. Through the study, in the first we found that all window close of the deaerator floor is one alternative for reducing the temperature of the operating floor. The next thing we knew that for windows open at the front of the deaerator floor, the temperature of deaerator zone and crane zone can be respectively reduced to $1.5^{\circ}C$ and $1.6^{\circ}C$. In addition, for windows close at the rear of the deaerator floor, the temperature of deaerator zone and crane zone can be respectively reduced to 1.4 and $0.5^{\circ}C$. Therefore, it was concluded that a better choice is to open the front windows at deaerator floor to reduce the temperature of the entire deaerator floor having high temperature.

Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature (AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석)

  • Kim, Min Ji;Yeon, Sang Hun;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

A Study on Energy Shutters to Reduce Infiltration Load of Buildings (건물의 침기부하 절감을 위한 에너지셔터에 관한 연구)

  • Gwang Soo Ko;Youn Cheol Park
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.2
    • /
    • pp.1-7
    • /
    • 2023
  • In this study, in order to reduce the amount of infiltration generated from windows among the heat loss generated in the building, energy shutters were installed on the windows to conduct experiments on the change in internal temperature and amount of infiltration due to the pressure difference between the environmental chamber and the pressure box. As a result of the experiment, when the pressure difference was 0Pa, the initial temperature of the pressure box of window was higher than that of the pressure box of the energy shutter, but when the pressure difference occurred, the internal temperature of the pressure box of the energy shutter was higher. In addition, the amount of infiltration of the energy shutter was lower than that of the windows in all experimental conditions, and it was concluded that the reduction rate of the infiltration load (of the energy shutters) could be reduced by 53.3% compared to that of the windows.

Analysis of Interior Noise for KTX Train using SEA (통계적 에너지 해석법을 이용한 KTX차량의 실내소음 해석)

  • Kim Jae-Chul;Lee Chan-Woo;Choi Sung-Hun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.783-788
    • /
    • 2004
  • Recently, Statistical Energy Analysis(SEA) is being increasingly applied to describe vibro-acoustic behavior of complex structures, such as air plane, automobile, ship, building. In this paper, we discuss the application of SEA to predict the interior noise for KTX train. To validate the SEA model of KTX train, calculated the interior noise for motorized car is compared to measured one. Finally, the reduction measures of interior noise for KTX are also discussed.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.