• 제목/요약/키워드: Building Energy Efficiency

검색결과 736건 처리시간 0.027초

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

농촌 마을회관 제로에너지 건축물 구축을 위한 에너지 성능 분석 연구 - 충남 태안군 정죽4리 마을회관을 중심으로 - (A study on the analysis of energy performance for zero-energy building of rural village hall - Focused on the Jung Juk 4-le village hall -)

  • 박미란;최정만;이정훈
    • 한국농촌건축학회논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.

제로에너지건축물의 공사비 증가분 산출에 관한 연구 (A study on the Increase in Construction Cost for Zero Energy Building)

  • 심홍석;이성주
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.603-613
    • /
    • 2021
  • 한국은 건물부문 온실가스 감축 목표 달성을 위한 핵심정책으로 2020년부터 공공부문 신축 건축물을 대상으로 제로에너지건축물 인증 의무화를 시행하였다. 이 논문은 제로에너지건축물을 활성화 시키고자 하는 정책 환경에서 건축 관계자들이 제로에너지건축 구현에 의사결정을 위해 참조할 수 있는 에너지절감 기술과 경제성 요인을 제시하는 것이 목적이다. 본 연구를 위해 최근 3년간 건축물 에너지효율등급 인증 자료와 공공기관을 대상으로 공사비 세부 내역서 자료를 수집하여 건축물 에너지 항목에 대한 공사비를 분석하였다. 또한, 건축물 에너지효율등급 인증 자료를 바탕으로 베이스라인 건축물의 각 에너지항목별 에너지성능을 도출하였으며, 베이스라인 건축물의 에너지항목에 대해 단계적으로 에너지성능 값을 상승을 시키는 반복적 시뮬레이션을 통해 제로에너지건축물의 에너지항목별 에너지성능 값을 도출하였다. 최종적으로 도출된 베이스라인 건축물과 제로에너지건축물의 에너지성능 값에 조사된 에너지항목별 공사비를 적용하여, 베이스라인 건축물과 제로에너지건축물의 에너지항목별 공사비를 도출하였다. 그 결과 제로에너지건축물을 구현하는 데 조명설비가 10.5%로 에너지절감에 가장 큰 기여를 하며, 냉·난방 시스템의 공사비 증가분이 9.1%로 가장 작은 것으로 분석되었다.

A Case Study of Electricity Usage Monitoring for Deterioration and Economic Analysis of Main Equipment in University Laboratory

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.706-707
    • /
    • 2015
  • Our country is aiming at 30% reductions in building energy consumption accounting for 39% of the total energy consumption by 2020[1]. For this purpose, the government is developing and applying the Building Energy Management System (hereinafter, referred to as "BEMS", Smart plug, etc.) while the researches on new renewable energy development. BEMS, which is applied with focus on large buildings, is inducing energy management of the entire building through energy measurement and data management, but considering its economic efficiency, it's very difficult to apply BEMS to small & medium-size buildings. Hereupon, this study intends to implement the case analysis of deterioration and economic efficiency of major equipment in buildings on the basis of electricity consumption which has been measured targeting small & medium-size buildings for a certain period by taking into account that equipment deterioration is a contributor to the increase in energy consumption.

  • PDF

에너지 성능지표 기계부문 항목에 따른 업무용 건물의 에너지 절감율 분석 (Analysis of Energy Saving Rate of Office Buildings According to the Items of an EPI Machine Part)

  • 이호진;김서훈;정재욱;장철용;송규동
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.49-54
    • /
    • 2013
  • released by IEA, 2010, indicated that Korea's GDP, of 8 countries surveyed-Korea, Frans, Germany, Italy, Japan, the UK, the USA, and Australia-was the lowest, but the electric consumption per head was third, following America and Australia. Thus, our government has been striving to reduce energy usage and especially to lessen the energy used in buildings, proposing a variety of road maps such as 'building energy efficiency rating' and 'energy saving design standards of buildings'. Accordingly, this study investigated the effect of the items of machine part among EPI items on the energy saving rate. I measured energy usage by ECO2 program, for simulation program, that is used for the building energy efficiency rating. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Therefore, I think that grades assigned to items in energy performance index need to be corrected.

발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가 (Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony)

  • 장철용;안병립;김치훈;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구 (A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency)

  • 장현숙;이상호
    • 한국건설관리학회논문집
    • /
    • 제13권6호
    • /
    • pp.3-12
    • /
    • 2012
  • 최근 민간건축 경기 침체가 거듭되면서 '신축' 시장 대비 비용 절감 효과는 물론, 자원절약 및 환경보호 효과를 거둘 수 있다는 긍정적인 반응과 함께 에너지성능향상형 리모델링 시장의 규모가 확대되고 있다. 서울시의 경우 2008년 시범사업을 시작으로 기존 건물에 대해 '건물에너지이용합리화사업(BRP)'를 추진, 시설개선사업을 통해 에너지 절감 및 이용 효율을 향상시킬 수 있도록 융자지원을 하고 있다. 2012년 보도자료에 따르면 254개소의 민간건축물이 참여, 친환경녹색건축물로 조성됨에 따라 온실가스 4만 1천톤/년을 감축, 석유환산 시 1만4천 TOE의 절감에 해당되어 매년 75억원의 에너지비용 절감효과를 보이고 있다고 한다. 본 연구는 기존 건물의 에너지 효율화 대책으로 리모델링 시 우선적으로 고려해야 할 에너지성능향상 방안 중 건축적 요소인 외피를 연구범위로 설정, 그 방안을 모색하였다. 그리고 해석모델에 적용, 분석함으로써 기존 건물의 에너지 절감효과, 즉 건물의 에너지성능향상 효과를 제시하였다. 연구의 범위가 외피 리모델링만을 고려한 건물의 에너지사용량을 감소시키는 단열보강 등의 목적지향적인 방법일 수 있겠으나, 대부분의 비주거용 업무시설의 경우 임대형이라는 점을 고려하였을 때 건축적 기술만을 적용한 방법의 모색은 실제 리모델링 시 가장 보편적인 기초자료가 될 수 있으므로 연구의 의미가 있다고 할 수 있다.

로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구 (A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing)

  • 이나은;안병립;장철용;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

창호 에너지 소비 효율 등급제와 건물 에너지 소비의 상관관계 분석 (Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption)

  • 곽희정;장향인;이현수;엄재용;서승직
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.338-345
    • /
    • 2013
  • The purpose of this study is to analyze the correlation between the 'Fenestration Energy Consumption Efficiency Rating System' (hereafter referred to as FECERS) and building energy consumption. 'EnergyPlus' was used for the calculation of energy consumption in apartments and office buildings, according to FECERS's rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption.

교육시설의 건축물에너지효율등급 사례분석을 통한 에너지자립률 평가 (Evaluation of Energy Self-Sufficiency Rate through Case Analysis of Building Energy Efficiency Rating in Educational Facilities)

  • 이현승;김지현;이승민;맹준호;신우철
    • 교육녹색환경연구
    • /
    • 제18권4호
    • /
    • pp.58-65
    • /
    • 2019
  • 교육시설은 '공공기관 에너지이용 합리화 추진에 관한 규정'에 따라 2014년부터 '건축물에너지효율 1등급 이상'의 의무대상건축물로 지정되었으며, 동 규정에서 정의하는 공공기관 건축물에 해당되어, 2008년 9월 신·재생에너지 의무대상 건축물로 포함되었다. 또한 2019년 4월 녹색건축물 조성 지원법이 개정됨에 따라, 2020년부터 ZEB인증의 의무대상 건축물로 확정되었다. 따라서 본 연구에서는 2015년 2월부터 2019년 5월까지 "건축물에너지효율등급" 본인증을 획득한 316개의 교육시설을 대상으로 "건물에너지효율등급" 및 "신·재생에너지시스템"설치 현황을 파악하고, 에너지 소요량 및 신·재생에너지 생산량을 기준으로 에너지자립률을 분석하였다. 316개 본인증 교육시설의 "건축물에너지효율등급"에 따른 ZEB 인증등급을 추정하면 1+++ 등급 12개 시설의 경우 1곳을 제외하고 모두 ZEB 5등급 이상으로 나타났으며, 239개의 1++ 등급 시설에서 11%에 해당하는 28곳이 ZEB 5등급 수준에 도달하였다. 따라서 현 수준에서 일반 교육시설의 ZEB 인증은 무리가 있으며, 건물에너지효율 1+++등급 상향과 신·재생에너지시스템 투자가 선행되어야 할 것으로 판단된다.