• Title/Summary/Keyword: Building Energy Assessment System

Search Result 131, Processing Time 0.025 seconds

Energy Performance and Cost Assessment for Implementing GroundSource Heat Pump System in Military Building (군사시설 내 지열 히트펌프 시스템 적용에 따른 에너지 성능과 비용 절감 효과 평가)

  • Byonghu Sohn;Kyung Joo Cho;Dong Woo Cho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.45-57
    • /
    • 2022
  • The Ministry of National Defense of the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of military facilities and to promote green growth policy in military sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. This paper analyzed energy performance and energy cost on the conventional heating and cooling system (baseline scenario) and three different alternative scenarios (ALT 1, ALT 2 and ALT 3) applied in a hypothetical military building. A building modeling and simulation software (DesignBuilder V6.1) with EnergyPlus calculation engine was used to calculate the energy consumption for each scenario. Overall, when the GSHPs are applied to both space airconditioning and domestic hot water (DHW) production, Alt-2 and Alt-3, the amount of energy consumption for target building can be greatly reduced. In addition, when the building envelope performance is increased like Alt-3, the energy consumption can be further reduced. The annual energy cost analysis showed that the baseline was approximately 161 million KRW, while Alt-3 was approximately 33 million KRW. Therefore, it was analyzed that the initial construction cost increase could be recovered within about 6.7 years for ALT 3. The results of this study can help decision-makers to determine the optimal strategy for implementing GSHP systems in military buildings through energy performance and initial construction cost assessment.

Study on feasibility analysis for ground source heat pump system using the building foundation (건물기초 이용 지열시스템의 도입 타당성 분석에 관한 연구)

  • Chae, Ho-Byung;Nam, Yujin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.155-157
    • /
    • 2013
  • Ground source heat pump(GSHP) systems have been attracted as high-efficient energy-saving technology, but the building clients and designers have hesitated to use GSHP systems which is a expensive initial installation and a uncertain economic feasibility. Therefore In order to reduce the initial cost, many researchers have focused on the energy-pile system using the structure of the building as a heat exchanger. Even though many of experimental studies for energy pile system have been conducted, there was not enough data of a quantitative evaluation with the economic analysis and comprehensive analysis for energy-pile. In this study, the feasibility study for the energy pile system with a barrette pile was conducted by the performance analysis and LCC assessment.

  • PDF

Study of the Assessment Baseline of Carbon Dioxide Emissions based on the Analysis of Building Energy Efficiency Rating System (건축물 에너지효율등급 인증현황분석을 통한 CO2 배출량 평가 베이스라인 연구)

  • Jung, Ho Gun;Shin, Sung Woo;Lee, Byeongho
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.11-19
    • /
    • 2013
  • The purpose of this study is to establish the assessment baseline of $CO_2$ emissions from building operations in the view of GHG reduction policy in Korea. The assessment baseline of $CO_2$ emissions shall be used in GHG policy and Carbon Credits in building sectors, but the assessment baseline has not been studied enough or established yet. Also, $CO_2$ emissions from building operations will be variable according to the building occupancy. Therefore the baseline will be different and this study aimed at the establishment of the assessment baseline for residential apartments and office buildings firstly. After reviews of BEER and international standards for building $CO_2$ emissions such as ISO and UNEP-SBCI documents, the analysis of BEER certification data has been pursued for 292 residential apartment complexes and 65 office buildings in South Korea during 2004~2012. As analysis results, the assessment baseline was set to 23.03 $kg{\cdot}CO_2/m^2{\cdot}yr$ or 1.95 $t{\cdot}CO_2/unit{\cdot}yr$ for residential apartment complexes, and 95.91 $kg{\cdot}CO_2/m^2{\cdot}yr$ for office buildings according to the BEER certification basis. Additional assessment baselines were calculated according to year basis, region basis, public and private basis, and GHG policy basis. Finally, the established baseline for residential apartment complexes has been applied for the pilot project in M district, Seoul, and showed 24.97% reduction rate according to the BEER certification basis.

An Assessment of the Energy Consumption & CO2 Emission during the Construction Stage of Government Building using the Input-Output Analysis (산업연관분석법을 통한 공공청사 신축공사단계의 에너지 소비량 및 CO2 발생량 평가)

  • Choi, Young-Hun;Lee, Sang-Beom;Song, Ho-San
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.149-150
    • /
    • 2011
  • Recently, Goverment's Energy-saving policy in Korea as 'Green Growth' is very remarkable effort. By intensive poliicies, the private is encouraged to participate in policy. Especially, it is very important in the field of architecture and we have to work for construction of law system. However, these efforts of the government buildings for energy efficiency in use stage is as mandatory system that may occur in the construction phase and the enviromental impact of greenhouse gas reductions is not affected. For this reason, Assess the amount of the energy consumption and CO2 emissioont of Government Buildings in 2010 ordered by PPS(Public Procurement Service) in the construction phase and suggest to recognize the need for legal restrictions.

  • PDF

A Study on the Improvement of New and Renewable Energy Certification Criteria in the Green Building Certification System (녹색건축 인증제도의 신·재생에너지 인증기준 개선에 관한 연구)

  • Lee, Mi-Ryeong;Park, Ji-Hye;Haan, Chan-Hoon;Tae, Choon-Seob
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.80-88
    • /
    • 2013
  • Deploying new and renewable energy should be encouraged due to scarce of natural resources and to reduce the $CO_2$ emission. Regarding the Green Building Certification System, '2.2.1 new and renewable energy use', and '2.3.1 carbon dioxide emission reductions' are related to new and renewable energy. Applying new and renewable energy can achieve the score in two criteria mentioned above and most of buildings get a perfect score in the green building certification system. So these criteria needs to be revised to have discrimination. In this study, supply rate of new and renewable energy of the buildings that have achieved Green Building Certification by E Green Building Certification Institute was analyzed. The improvement of assessment criteria related to new and renewable energy is proposed and could be applied to the revisions.

A Study on Green Building Certification Criteria for Healthcare Facilities - Focused on System and Contents for Healthcare in BREEAM, LEED, CASBEE (녹색건축물 인증제도의 의료시설 평가에 관한 연구 - BREEAM, LEED, CASBEE의 평가방법과 평가내용 비교·분석을 중심으로)

  • Yoon, Eunji;Lim, Younghwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.3
    • /
    • pp.17-26
    • /
    • 2016
  • Purpose: As the concerns for the environment are gradually prioritized, increasing interests of environment-friendly buildings are drawn. The Green Standard for Energy & Environmental Design (G-SEED) has been strengthened. However, there are no specific assessment criteria that reflect the special situation of healthcare facility. UK, US and Japan have green building certifications specially designed to evaluate sustainable healthcare facilities. This study has been started in order to provide basic information for developing assessment criteria for healthcare facilities in Korean Green Standard for Energy and Environmental Design. Methods: In this study, we investigated three foreign green building certifications and compared their assessment system and criteria for healthcare buildings. Results: Each of the three foreign certification standards showed the difference in the system, but all contained the contents specific to healthcare facilities. Evaluation items were affected by regional cultural environment and also medical environment. Patient safety and integrative planning were the most important assessment contents. Implications: Based on this analysis, Korean Green Standard for Energy & Environmental Design for healthcare facilities will be developed.

A Development of the On-line Maintenance and Management System for the HVAC system Using IT (IT를 활용한 공조설비의 온라인 유지관리시스템 개발)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju;Woo, Nam-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.48-53
    • /
    • 2008
  • The performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. A major use of building energy management system(BEMS) is for monitoring plant and building's energy consumption. National building management system (N-BMS) presented in this study links buildings into a network group in order to monitor and control the buildings. How to construct the N-BMS was considered to save energy resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

Environmental Impact Assessment at a School Building using Input-output Table - Focused on Elementary School in Gyeonggi-do - (산업연관분석법을 이용한 학교 건물에서의 환경영향평가 - 경기지역의 초등학교를 대상으로 -)

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: A lot of active researches have addressed the impact of a building on global environment, but most of the researches focus on a residential building and a large office building. Hereupon, this study assessed the impact on environment quantitatively through the analysis of input materials targeting a school building. Method:This study calculated embodied energy of input materials suggested in a construction statement on a school building using the input-output analysis. This study finally carried out environmental impact assessment by applying LCIA DB shown in the preceding researches to the calculated embodied energy. Result: The analysis result revealed that the environmental impact per unit area(/$m^2$) at a school building was $4.11E-02PE{\cdot}yr$, among which Construction was found to be $3.59E-02PE{\cdot}yr$, being analyzed to account for about 87% of the total environmental impact. Also, as a result of detailed environmental impact, the impact on global warming among the total environmental impact was analyzed to be high, accounting for about 76%.

A Comparative Study on Management Evaluation and Re-certification System of G-SEED, BREEAM, LEED (국내외 녹색건축인증제의 유지관리 및 재인증 제도에 대한 비교 연구)

  • Hyun, Eun Mi;Kim, Yong Sik
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.121-129
    • /
    • 2014
  • As time passes, the aging of the plant building, the building's energy performance degradation than the initial plan does not express a situation could arise. This year, the certification of buildings certified in 2009 has expired for measures such as the situation required. In this study, management of national and international green building certification and re-certification was compared in two ways. First, the evaluation of green building certification system management assessments were compared. Second, the green building certification system for the re-certification analysis. As a result, G-SEED was not reflected life-cycle of building in management assessment and the commissioning of G-SEED is the UK and the U.S and other concepts of evaluation. In addition, the re-certification system is insufficient about substantial energy consumption of buildings. In this study, the revised the management assessments in conjunction with the re-certification system to manage the building is proposed to improve. In addition, the current evaluation of the existing building certification "existing building" and "building the first certified" as it is more efficient to separate the information into assessment was judged. Green building certification system to meet the purpose of management and operation, and disposal phases of the building to promote energy conservation and sustainability in order to the management a systematic and detailed evaluation and re-certification system developed for the revision of the specific items required and future research want to continue.

Development of the IFC based IDF Converter for Energy Performance Assessment in the Early Design Phase (초기 설계단계 에너지 성능평가를 위한 IFC 기반 IDF 변환기 개발)

  • Kim, In-Han;Kim, Ji-Eun;Choi, Jung-Sik
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.146-155
    • /
    • 2011
  • As the seriousness of environmental pollution being on a rise, a low carbon and environment-friendly design for energy efficiency has been issued. With respect to energy in the construction industry, an adoption of BIM which is possible for the various energy performance assessments in the early design phase has been actively working on. In the most cases of energy performance assessment, the data compatibility from the lack of standard software and format became a problem and the improvement for data compatibility system has been needed. This study is to develop the IFC based IDF converter as a middleware which connects between BIM software and energy analysis software. For the building energy performance assessment, Energy Plus and IFC are selected for the standard energy analysis software and its file format. Parameters are organized by steps and the integrated material library is built so it is trying to reduce the existing problem of energy software interface as much as possible. The development of IDF Converter will promote the spread of related fields with increasing the BIM standard and the utilization of energy performance assessment.