• Title/Summary/Keyword: Building Density

Search Result 810, Processing Time 0.024 seconds

An Experimental Study on the Compressive Strength of Cement Paste Considering Relative Density (상대밀도를 고려한 시멘트 페이스트 압축 강도에 관한 실험적 연구)

  • Jang, Jong-Min;Jang, Hyun-O;Lee, Han-Seun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.160-161
    • /
    • 2017
  • In In this study, we measured the relative density and the compressive strength in order to select the appropriate W/B for the ultra-high strength concrete development. If W/B is lowered than the W/B of highest relative density, it was confirmed that the strength is lowered. However, if water is increased than the W/B, the relative density is decreased compressive strength was similar. The selection of the W/B of the lower than the highest relative density is not appropriate. Appropriate W/B is selected to be more than the maximum relative density of W/B. This was confirmed for TG-DTA.

  • PDF

An Experimental Study on appropriate water-binder ratio for development of ultra high strength concrete (초고강도 콘크리트 개발을 위한 적정 물-결합재비 선정에 관한 실험적 연구)

  • Jang, Jong-Min;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.79-80
    • /
    • 2016
  • In this study, we measured the relative density and the compressive strength in order to select the appropriate W/ B for the ultra-high strength concrete development. If W/B is lowered than the W/B of highest relative density, it was confirmed that the strength is lowered. However, if water is increased than the W/B of highest relative density, the relative density is decreased compressive strength was similar. The selection of the W/B of the lower than the highest relative density is not appropriate. Appropriate W/B is selected to be more than the maximum relative density of W/B.

  • PDF

An Effects of Air-Assisted-Catalyst Element for Reducing Density of Formaldehyde in a New House (신축주택에서 포름알데히드 농도저감에 대한 공기 촉매제의 효과에 관한 연구)

  • Jo, Hyeon-U;Park, U-Yeol;Jo, Hun-Hui;Jo, Ho-Gyu;Gang, Gyeong-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • The sick house syndrome is occurred from the harmful elements that the building interior materials are given off after building construction or renovation. The appropriate methods, which is to prevent sick house syndrome from spreading have to be selected before building construction or renovation. Thus, this study is to measure the density of formaldehyde, one of the volatile organic compounds after sprinkling air-assisted-catalyst on the building interior space. As a result, the emit value of formaldehyde is measured 0.07ppm that is lower than the standard of Environmental Protection Agency and World Health Organization, 0.1ppm, and the standard of Ministry of Health, Labour, and Welfare of Japan, 0.08ppm.

Evaluation for Mechanical Properties of Compress Strength and Dry Density of Concrete at NPP (원전 시설용 콘크리트의 압축강도 및 건조밀도 특성 평가)

  • Lee, Young-Dae;Kim, Gyu-Yong;Shin, Kyoung-Su;Nam, Jeong-Soo;Lee, Tae-Gyu;Choe, Gyeong-Choel
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.53-54
    • /
    • 2011
  • The facilities producing the nuclear energy chosen for resolving the recent global energy problem have been increasingly constructed, and hence more frequent durability tests on radiation shielding concrete are required due to NPP(Nuclear Power Plant) life extension and increase of radioactive waste repositories. Bulk dry density is one of the critical factors ensuring the durability and performance of the radiation shielding concrete because the design of the radiation shielding reinforced concrete structures for NPPs is based on the bulk dry density of the concrete. Bulk density of unconsolidated shielding concrete can be calculated utilizing a test assuring to satisfy the bulk dry density, or existing credible data set. This study evaluated correlation between bulk density and bulk dry density of the concrete used for Korean NPPs (y=1.0913X-0.2458) and developed a correlation expression considering standard deviation of bulk dry density (y=1.0913X-0.3358).

  • PDF

Development of Eco Cementitious Building Finishing Materials Modified with Bamboo Charcoal (대나무 활성탄 함유 시멘트계 재료의 친환경 건축마감재로서의 개발을 위한 기초적 연구)

  • Park, Dong-Cheon;Kwon, Sung-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.452-458
    • /
    • 2011
  • Bamboo is representing environmentally friendly building finishing materials as proven in the former researches. The purpose of this study is to evaluate the application properties of cementitious materials modified with bamboo charcoal as building finish materials. Flow test in fresh condition was conducted to assess the workability. Compressive and bending strength were measured after harding. As the thermal properties, thermal conductivity and density were measured. The properties were surpassing over them in case of using the pine charcoal in every tests. The thermal conductivity of them increased with the modified ratio. After the modified ratio 50%, the thermal conductivity decreased. Insolation and absorption performance is due to the lower density by modification of bamboo charcoal.

In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System (빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구)

  • Shin Younggy;Yang Hooncheul;Tae Choon-Seob;Cho Soo;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

A Study on the Change of Architecture Density and Residential Environment according to Reconstruction (재건축에 따른 건축밀도 및 주거환경의 변화 연구)

  • Kim, Hong-Bae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • This study aims to investigate the change in building density and residential environment after the reconstruction of decrepit public rental housing complexes formed in accordance with the Land Readjustment Project during the 1970s-80s. The results of this study can be summarized as follows: First, in terms of change in residential environment after the reconstruction, floor plans that were limited to two to four types and to small apartments measuring $42.9m^2$(13py)-$56.1m^2$ (17py) became varied, presenting 5-6 types of floor plans and various sizes of apartments. In particular, the reconstructed apartments were mainly built in a size smaller than 85($m^2$) and in the 3LDK floor plan and staircase-style unit architectural structure in order to reflect the lifestyle of residents. Second, in terms of change in building density after the reconstruction, the building coverage ratio did not change a lot, but the floor area ratio showed great change depending on the complex, ranging from a minimum of 2.9 times (Singdong Complex) to a maximum of 5.4 times (Eoyangdong Complex). Such change is attributable to the reconstruction policy that aims to improve the residential environment for original residents, secure economic feasibility and efficiency, and reflect the lifestyle of residents while incorporating dividends assigned to the existing housing project members as well as the maximum floor area ratio allowed by the regulation. Additionally, in terms of change in the number of floors and building density after the reconstruction, the former 5-story apartments were changed to apartments with 16-28 stories. Accordingly, the number of households in each complex has also increased by 20%. Third, according to the characteristics of parking facilities in terms of the size and density of parking spaces, former apartment complexes had only aboveground parking lots, not underground parking area. The newly constructed apartment complexes have underground parking space, and the parking-housing ratio is 1.1-1.3 cars.

Impacts of the Building Permit Area Change on the Forest Products Import Quantities in Korea (건축허가면적(建築許可面積)의 변화(變化)가 임산물(林産物) 수입(輸入)에 미치는 영향(影響))

  • Kim, Dong-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.2
    • /
    • pp.217-226
    • /
    • 2001
  • This study estimated the impacts of the building permit area change on the forest products import quantities in Korea. The first objective of this dissertation is to analyze whether there is any causal relationship between change in the building permit area and changes in the import quantities of forest products in Korea. Assuming that there is any causal relationship, the second objective is to evaluate the dynamics of the impacts of the building permit area change on the forest products import quantities in Korea. The relationship between the building permit area and the import quantity was represented by bivariate vector autoregressive or vector error correction model. Whether there is any causal relationship between change in the building permit area and changes in the import quantities of forest products was analyzed by the causality test of Granger. And the dynamics of the impacts of the building permit area change on the forest products import quantities were evaluated by variance decomposition analysis and impulse response analysis. The import quantity of forest products can be explained by the lagged building permit area variables and the lagged import quantity variables in Korea. Change in the building permit area causes change in the high-density fiberboard import quantity in Korea. In the bivariate model of the high-density fiberboard import quantity, after six months, the building permit area change accounts for about ten percent of variation in the import quantity, and its own change accounts for about ninety percent of variation in the import quantity. On the other hand, the impact of a shock to the building permit area is significant for about six months on the import quantity of high-density fiberboard in Korea. That is, if the building permit area change indeed had an impact on the import quantity of high-density fiberboard in Korea, it was only of a short-term nature.

  • PDF

Properties of Low Density Foamed Concrete for Building Construction Using Anionic Surfactants of Synthetic and Natural Materials

  • Jeong, Ji-Yong;Kim, Jin-Man
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.557-566
    • /
    • 2011
  • The surfactants facilitate the formation of foam bubbles under a proper condition and provide stability of foam bubbles by decreasing the surface tension of solutions and increasing the viscosity of foam surface. However, there have been almost no practical data of foam concrete in this regard so far. This study aims to understand the effects of foaming agents such as anionic synthetic surfactant and anionic natural material surfactant on the low density foamed concrete. From the experiment, the vegetable soap of anionic natural material surfactants showed a higher foaming rate, more open pores, slightly lower compressive strength, and a higher permeability coefficient compared to the vegetable soap of anionic synthetic surfactants. It is believed that the natural material surfactants make not only the surface tension of the solution low but also the viscosity of slurry high.