• Title/Summary/Keyword: Bubble Detection

Search Result 30, Processing Time 0.022 seconds

Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector (나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기)

  • Shin, Im-Hyu;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1104-1112
    • /
    • 2013
  • This paper presents a wideband Colpitts voltage controlled oscillator(VCO) with nanosecond startup time and a center frequency of 8.35 GHz for a new bubble-type motion detector that has a bubble-layer detection zone at the specific distance from itself. The VCO circuit consists of two parts; one is a negative resistance part with a HEMT device and Colpitts feedback structure and the other is a resonator part with a varactor diode and shorted shunt microstrip line. The shorted shunt microstrip line and series capacitor are utilized to compensate for the input reactance of the packaged HEMT that changes from capacitive values to inductive values at 8.1 GHz due to parasitic package inductance. By tuning the feedback capacitors which determine negative resistance values, this paper also investigates startup time improvement with the negative resistance variation and tuning bandwidth improvement with the reactance slope variation of the negative resistance part. The VCO measurement shows the tuning bandwidth of 2.3 GHz(28 %), the output power of 4.1~7.5 dBm and the startup time of less than 2 nsec.

A Study on the Development of a Infusion Pump based on an Active Muscle Pump (능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구)

  • Lee, Jeong-Whan;Lee, Sang-Yeob;Lee, Jung-Eun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.

Multi-phase Flow Velocity Measurement Technique using Shadow Graphic Images (다위상 유체 속도 계측을 위한 영상기법 적용)

  • Ryu, Yong-Uk;Jung, Kwang-Hyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.61-65
    • /
    • 2012
  • Air-water flow measurements are of importance for the coastal and ocean engineering fields. Although kinematic investigations of the multi-phase flows have been conducted for long time, velocity measurements still are concerned with many researchers and engineers in coastal and ocean areas. In the present study, an imaging technique using shadowgraphy and fiber optic probe for velocity measurements of air bubbles is introduced. The shadow graphy image technique is modified from the typical image velocimetry methods, and optical fibers are used for the well-known intrusive coupled phase-detection probe system. Since the imaging technique is a non-intrusive optical method from the air, it is usually applied for 2D flows. On the other hand, the double fiber optic probes touch flows regardless of flow patterns. The results of the flow measurements by both methods are compared and discussed. The methods are also applied to the measurements of overtopping flows by a breaking wave over the structure fixed on the free surface.

A Case of Wooden Foreign Body Misinterpreted as Facial Abscess and Osteitis (안면부 농양 및 골염으로 오인된 나무 이물 1례)

  • Kim Eun-Seo;Kim Young-Chul;Kim Sok-Chon;Hong Seok-Chan
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.235-237
    • /
    • 2000
  • It is difficult to find the penetrating foreign bodies in the head and neck area only with history taking and physical examinations. One of the most important things is to detect the precise location of foreign bodies or possibly remained materials. The detection of wooden foreign bodies is important because they can cause phlegmon formation and because wood is often contaminated by Clostridium tetani bacteria. CT has proved to be an expedient method for detecting foreign bodies of various materials in soft tissues, but the wooden foreign body is often misinterpreted as a gas bubble in soft tissue. We have experienced a case of wooden foreign body which has penetrated through nasal dorsum and remained for 4 months. It had been initially misinterpreted as longstanding inflammatory lesion and osteitis of maxilla and nasal bone.

  • PDF

Bursoscopic Evaluation for Degree of the Rotator Cuff Tear with Air Infusion Method (공기 주입과 동시에 시행한 견봉하 관절경 술식을 이용한 회전근개 파열의 정도 평가)

  • Moon, Young-Lae;Sohn, Hong-Moon;Kim, Nam-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.126-130
    • /
    • 2002
  • Purpose : To evaluate the diagnostic efficiency of the subacromial bursoscopy with glenohumeral air infusion technique for detection of the full thickness tear which we used to think as a partial thickness tear, because it was hidden by bursal tissue. Materials and methods : We chose 65 cases and divided them into 2 groups. The group I was 18 cases with partial thickness rotator cuff tears on glenohumeral arthroscopic evaluation, and the group 2 was 37 cases with full thickness rotator cuff tears which were repaired. We inflated the glenohumeral Joint with 50-100ml of air and observed air bubble leakage simultaneously on bursoscopy. Results : In group I, we could detect air leakage in 3 cases and found that it was full thickness tear. In group II, 2 cases revealed too much air leakage proved that it was incomplete repair and was in need of additional suture. Conclusion : Air infusion technique is though to be a valuable method in differentiation between the partial and full thickness tear and for evaluation of the security of the repair.

  • PDF

Solanum Nigrum Polysaccharide (SNL) Extract Effects in Transplanted Tumor-bearing Mice - Erythrocyte Membrane Fluidity and Blocking of Functions

  • Yuan, Hong-Liang;Liu, Xiao-Lei;Liu, Ying-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10469-10473
    • /
    • 2015
  • Background: Solanum nigrum L. has been used in traditional Chinese medicine because of its diuretic and antipyretic effects. The present research concerned effects of crude polysaccharides isolated from Solanum nigrum L. on erythrocyte membranes of tumor-bearing $S_{180}$ and $H_{22}$ in mice. Materials and Methods: Fluorescence-labeled red blood cell membranes were used with DPH fluorescence spectrophotometry to examine erythrocyte membrane fluidity, and colorimetry to determine degree of erythrocyte surface membrane blocking. Extent of reaction by tumor-bearing mice with the enzyme erythrocyte membrane bubble shadow detection of red cell membrane variation in the degree of closure before and after administration. Results: Solanum nigrum polysaccharide could significantly improve the $S_{180}$ and $H_{22}$ tumor-bearing mice erythrocyte membrane fluidity, compared with the control group, the difference was significant (p<0.01), SNL can significantly improve the red blood cell membrane and then $S_{180}$ tumor-bearing mice sealing ability, compared with the negative control group, the difference was significant(p<0.05, p<0.01). $H_{22}$ tumor-bearing mice can increase red cell membrane and then sealing ability, the difference was significant (p<0.05). Solanum nigrum polysaccharide degree of fluidity and blocking two transplanted tumors in mice restored the ability to raise the red cell membrane has a significant effect. Conclusions: Solanum nigrum L.-type mice transplanted tumor can affect the red blood cell membrane fluidity and re-closed, through the red cell membrane of red blood cells to enhance the immune function of the possibility of erythrocyte immunity against tumor formation garland provide experimental basis.

Medical Parameter Extraction Using Time-Density Data in Contrast-Enhanced Ultrasound Image Sequence (조영증강 초음파영상에서 밀도변화 데이터를 이용한 진단 파라미터 추출 기법)

  • Lee, Jun-Yong;Jung, Joong-Eun;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.7
    • /
    • pp.297-300
    • /
    • 2015
  • In medical ultrasonography, transit time and contrast enhancement patterns are considered as important parameters to analyze liver diseases. In many recent researches, time-intensity curves(TIC) have been used for calculating the transit time of the contrast agents. However, the intensity curve may include the variations which are caused by the micro-bubble effect of contrast agents. In this paper, we propose a complementary approach to diagnostic parameter extraction which utilizes a density information as well as the intensity data. The proposed technique improves the accuracy in extraction of the transit time and velocity of contrast agents for detection and characterization of focal liver lesions. Through the experiments using a set of clinical data, we show that the proposed methods can improve the reliability of the parametric image data.

Study on the Model Tests of Cavitation Erosion Occurring in Navy Ship's Flat-Type Rudder (함정의 평판형 방향타 캐비테이션 침식에 대한 모형 시험 연구)

  • Bu-Geun Paik;Jong-Woo Ahn;Young-Ha Park;So-Won Jeong;Jae-Yeol Song;Yoon-Ho Ko
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.1
    • /
    • pp.31-37
    • /
    • 2023
  • In the present study, a method of performing cavitation erosion test directly on the anodized surface of the rudder model is proposed, not applying ink or paint on its surface. An image processing technique is newly developed to quantitatively evaluate the erosion damages on the rudder model surface after erosion test. The preprocessing saturation image, image smoothing, adaptive hysteresis thresholding and eroded area detection algorithms are in the image processing program. The rudder cavitation erosion tests are conducted in the rudder deflection angle range of 0° to -4°, which is used to maintain a straight course at the highest speed of the targeted navy ship. In the case of the conventional flat-type full-spade rudder currently being used in the target ship, surface erosion can occur on the model rudder surface in the above rudder deflection angle range. The bubble type of cavitation occurs on rudder surface, which is estimated to be the main reason of erosion damage on the rudder surface.

Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring (막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.248-254
    • /
    • 2017
  • In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of $3{\mu}m$ or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT).

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.