• Title/Summary/Keyword: Broken bar

Search Result 58, Processing Time 0.023 seconds

Bar Suture for the Treatment of Bovine Abomasal Displacement (소의 제4위전위증 교정을 위한 봉봉합법)

  • Cho Myoung-Rae
    • Journal of Veterinary Clinics
    • /
    • v.9 no.1
    • /
    • pp.261-266
    • /
    • 1992
  • Surgical treatment was performed in 507 heads out of 1078 dairly cows which were diagnosed as abomasal displacement. Out of 507 heads. bar suture was performed in 280 heads. Twelve heads out of 280 heads(4.9%) recurred. Incorrective suture of the reticulum or pylorus instead of abomasum occurred in 3 cows. The cows in which abdominal wall was sutured but the suture was not inserted into the abomasum were 4 heads. The cows in which bar was broken are 4 heads. A cow suffered peritonitis after bar suture. Bar suture technique is thought to be a good method as a first choice for the correction of abomasal displacement.

  • PDF

Fabrication of Single Capacitive type Differential pressure sensor for Differential Flow meter (차압식 유량계를 실장을 위한 Single Capacitive Type Differential 압력 센서 개발)

  • Shin, Kyu-Sik;Song, Sangwoo;Lee, Kyungil;Lee, Daesung;Jung, Jae Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • In this paper, we have developed a differential pressure flow sensor designed as a single capacitive type. And the sensor was fabricated using a MEMS process. Differential pressure flow sensors are the most commonly used sensors for industrial applications. The sensing diaphragm and bonding joint of the MEMS pressure sensor are easily broken at high pressure. In this paper, we proposed a structure in which the diaphragm of the sensor was not broken at a pressure exceeding the proof pressure, and the differential pressure sensor was designed and manufactured accordingly. The operating characteristics of the sensor were evaluated at a pressure three times higher than the sensor operating pressure (0-3 bar). The developed sensor was $3.0{\times}3.0mm$ and measured with a LCR meter (HP 4284a) at a pressure between 0 and 3 bar. It showed 3.67 pF at 0 bar and 5.13 pF at 3 bar. The sensor operating pressure (0-3 bar) developed a pressure sensor with hysteresis of 0.37%.

Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process (가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향)

  • Kim, Junhyun;Moon, Baeksu;Park, Jongsu;Cho, Yoonho;Kim, Jinho
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.460-468
    • /
    • 2013
  • This study reviewed optimum dosage rate of coagulant and ability to remove dissolved organic carbon without sedimentation in conventional water purification plant. It was confirmed that floc formated by pre-treatment process was broken by impeller of booster pump. Optimum dosage rate of coagulant was 4 mg/L (as PACl 17%) for floc formation through blend, coagulation and after passing through the pump when turbidity of raw water was less than 10 NTU. And average removal rate of dissolved organic carbon was 43% at that time. Maximum removal rate of dissolved organic carbon was 48%, even though coagulation rate was increased gradually until 8 mg/L (as PACl 17%). So removal rate of dissolved organic carbon is not much improved even if dosage rage of coagulant increase. TMP of PVDF (polyvinylidene flouride) pressurized MF process without pre-treatment operated at 0.54 bar and TMP of PVDF pressurized MF process with pre-treatment operated at 0.41 bar.

A Study of Rotor Fault Detection for the Induction Motor Using Axial Leakage Magnetic Flux (축방향 누설자속 측정에 의한 유도전동기의 회전자 결함검출에 관한 연구)

  • Shin, Dae-Cheul;Kim, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.132-137
    • /
    • 2006
  • The second part of paper related rotor failure is to evaluate that the axial magnetic flux measurement could be used as a tool of the condition monitoring system for the induction motor and to develope the diagnostic algorithm for the various fault in the electric motors. The magnetic leakage flux signal is captured by the flux coil located at the end of motor without the disturbance of the operation. And the signal is analyzed both time and frequency domain to detect the failure of the motor. Specific signature can be described in tin and frequency domain for each fault of the motor. The experimental test found that the rotor failures - broken rotor bar, broken end ing and rotor eccentricity, could be detected from the spectrum with high resolution. The method of detecting the rotor fault was found by analysing the specific frequency and the sideband of the rotor bar pass frequency from axial leakage flux spectrum. In addition the optimal flux coil and measuring equipment for the axial leakage flux measurement was verified and the diagnostic method for the detection of the rotor related failure was developed.

A Study on The Broken Rotor Bars in Induction Motor and The Controll Characteristics in Inverter (유도전동기 로터바의 손상과 인버터 제어특성에 관한 연구)

  • Kim K.W.;Kwon J.L.;Lee K.J.;Choi K.S.;Lee H.S.;Chang S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.464-466
    • /
    • 2001
  • The advantage of the squirrel cage induction motor is the brushless rotor. This advantage for operation and maintenance turns out to be a disadvantage for the detection of the cage rotor bar and endring defects, which means that the detection of cage faults is due to the measurement and analysis of only the stator input signals. The monitoring task in an inverter drive is complicated mainly because the voltage and current waveforms are nonsinusoidal and the high dv/dt values from fast switching inverterd distort the measurements. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA).

  • PDF

CPM Bar Chart Technique for Construction Scheduling (CPM Bar Chart 기법을 활용한 일정계획)

  • Kim Kyung-Hwan;Kim Soo-Yoo;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.5 s.21
    • /
    • pp.135-142
    • /
    • 2004
  • This paper proposes the CPM bar chart (CBC), a hybrid of the bar chart and the critical pad method (CPM). The CBC overcomes shortages of the fenced bar chart, while still keeping advantages. The fence with direction is applied instead of the broken fence, which triggers considerable problems to identify and apply in the fenced bar chart. In addition, the notorious task to find dummy activities is no longer required. Upon the benefits of simplicity in the bar chart and logical work sequence in the CPM network. the CBC provides a relatively easy way to create and understand a schedule, thus improving communication quality between project participants. With the advantages, the CBC can also be effectively applied to various scheduling techniques such as resource constrained scheduling, resource leveling, scheduling with activity split, delay impact analysis, etc.

Comparative study on dynamic properties of argillaceous siltstone and its grouting-reinforced body

  • Huang, Ming;Xu, Chao-Shui;Zhan, Jin-Wu;Wang, Jun-Bao
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.333-352
    • /
    • 2017
  • A comparison study is made between the dynamic properties of an argillaceous siltstone and its grouting-reinforced body. The purpose is to investigate how grout injection can help repair broken soft rocks. A slightly weathered argillaceous siltstone is selected, and part of the siltstone is mechanically crushed and cemented with Portland cement to simulate the grouting-reinforced body. Core specimens with the size of $50mm{\times}38mm$ are prepared from the original rock and the grouting-reinforced body. Impact tests on these samples are then carried out using a Split Hopkinson Pressure Bar (SHPB) apparatus. Failure patterns are analyzed and geotechnical parameters of the specimens are estimated. Based on the experimental results, for the grouting-reinforced body, its shock resistance is poorer than that of the original rock, and most cracks happen in the cementation boundaries between the cement mortar and the original rock particles. It was observed that the grouting-reinforced body ends up with more fragmented residues, most of them have larger fractal dimensions, and its dynamic strength is generally lower. The mass ratio of broken rocks to cement has a significant effect on its dynamic properties and there is an optimal ratio that the maximum dynamic peak strength can be achieved. The dynamic strain-softening behavior of the grouting-reinforced body is more significant compared with that of the original rock. Both the time dependent damage model and the modified overstress damage model are equally applicable to the original rock, but the former performs much better compared with the latter for the grouting-reinforced body. In addition, it was also shown that water content and impact velocity both have significant effect on dynamic properties of the original rock and its grouting-reinforced body. Higher water content leads to more small broken rock pieces, larger fractal dimensions, lower dynamic peak strength and smaller elastic modulus. However, the water content plays a minor role in fractal dimensions when the impact velocity is beyond a certain value. Higher impact loading rate leads to higher degree of fragmentation and larger fractal dimensions both in argillaceous siltstone and its grouting-reinforced body. These results provide a sound basis for the quantitative evaluation on how cement grouting can contribute to the repair of broken soft rocks.

Online Fault Diagnosis of Motor Using Electric Signatures (전기신호를 이용한 전동기 온라인 고장진단)

  • Kim, Lark-Kyo;Lim, Jung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1882-1888
    • /
    • 2010
  • It is widely known that ESA(Electric Signature Analysis) method is very useful one for fault diagnosis of an induction motor. Online fault diagnosis system of induction motors using LabVIEW is proposed to detect the fault of broken rotor bars and shorted turns in stator. This system is not model-based system of induction motor but LabVIEW-based fault diagnosis system using FFT spectrum of stator current in faulty motor without estimating of motor parameters. FFT of stator current in faulty induction motor is measured and compared with various reference fault data in data base to diagnose the fault. This paper is focused on to predict and diagnose of the health state of induction motors in steady state. Also, it can be given to motor operator and maintenance team in order to enhance an availability and maintainability of induction motors. Experimental results are demonstrated that the proposed system is very useful to diagnose the fault and to implement the predictive maintenance of induction motors.

Fault Diagnosis of Rotor Bars in a Single Phase Induction Motor Monitoring Electromechanical Parameters (기전연성계 해석을 이용한 단상유도전동기의 회전자 결함진단에 관한 연구)

  • Park, S.J.;Chang, J.H.;Jang, G.H.;Lee, Y.B.;Kim, C.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.802-808
    • /
    • 2000
  • This paper characterizes the electromechanical parameters due to the fault of rotor bars in a squirrel cage induction motor. Simulation is performed to investigate how broken rotor bars have effect on them by solving the time-stepping finite element equation coupled with magnetic field equation, circuit equation and mechanical equation of motion. It shows that the asymmetry of magnetic flux due to the broken rotor bar introduces the beating phenomenon in time domain and the sideband frequencies in frequency spectra, respectively, to the stator current, torque, speed, magnetic force and vibration of a rotor. However, vibration of a rotor would be the most effective monitoring parameters to detect the faults of rotor bars.

  • PDF

On-Line Assessment of High Voltage Motor Condition using the Motor Performance Monitor (MPM을 이용한 고압전동기 운전중 상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1589-1593
    • /
    • 2008
  • The condition of a high voltage motor was monitored with the motor performance monitor (MPM) at the motor control center. The MPM detected defects in the rotor bar and end ring and input power according to motor and load conditions. The assessment of the condition of a coal pulverizer motor indicated it was clearly in good condition in terms of the rotor bars, over voltage, and motor performance. However, the side bands at frequency, 56.48 Hz indicated existence of rotor end-ring fault. The large torque ripple indicated abnormal operating conditions. After visual inspection, it has been observed that an impeller blade of the circulating water pump was broken off causing the irregular torque pattern.