• 제목/요약/키워드: Broiler house

검색결과 73건 처리시간 0.028초

육계의 계사 형태와 시설수준이 사육환경과 생산성에 미치는 영향 (Effect of Housing and Production System on Environment and Performances in Broiler Production)

  • 최희철;서옥석;이덕수;한정대;강보석;이상진;김상호
    • 한국축산시설환경학회지
    • /
    • 제5권2호
    • /
    • pp.87-92
    • /
    • 1999
  • Three types of commercial broiler farms were surveyed to evaluate the effects of housing and production systems on environment and performances in broiler production. Environment condition of broiler house was better in windowless type than vinyl house. Ammonia, carbon dioxide and dust in vinyl house was 28ppm, 2,000ppm, 50.5CPM, respectively. Mortality was higher in vinyl house than that of widowless broiler house. Body weights at the age of 39 days were 1,551g, 1,607g and 1,620g of vinly house, open-sided broiler house and windowless broiler house, respectively. The incidence of abnormal carcass from the vinyl house was higher than those of the others.

BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석 (Analysis of Heating Load of a Naturally Ventilated Broiler House using BES Simulation)

  • 홍세운;이인복;홍희기;서일환;황현섭;;유재인;권경석;하태환;김기성
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.39-47
    • /
    • 2008
  • Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation(BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

육계에 있어서 계분의 배설량과 이화학적 특성에 관한 연구 (Research on Quantity and Characteristics of Excreta Produced by Broiler)

  • 이덕수;최희철;곽정훈;강희설;최동윤;한정대;김형호
    • 한국축산시설환경학회지
    • /
    • 제7권1호
    • /
    • pp.33-38
    • /
    • 2001
  • 육계의 분 배설량과 그 특성을 알아보고자 축산기술연구소 시험계사에서 육계 120수를 이용하여 시험을 실시하였으며 그 결과는 다음과 같다. 1. 육계는 6주령시 수당 일일 160.1~165.2g의 사료를 섭취했으며 암텃, 213.0$m\ell$,수컷 252.9$m\ell$의 물을 섭취하였다. 2. 육계 1수당 1일 암수 평균 배설량은 6주령시 생분기눙으로 90.5g이며 육계 1수가 42일령까지 배설하는 누적배설량은 암수 평균 3,800g이었고 이때 계분중의 수분 함량은 79.4%였다. 3. 육계분의 평균 N 함량ㅇㄴ 건물기준으로 N 1.19%, $P_2O_5 1.28%, K_2O$ 2.02%였다. 4. 무창육계사의 여름철 깔짚 중의 수분 함량은 18.3%로 자연환기식 개방계사 계분의 수분함량 29.7%, 간이계사 30.1%보다 낮았다.

  • PDF

표준육계사의 지붕을 활용한 태양에너지 설비 타당성 분석에 관한 기초 연구 (A Basic Study on Feasibility Analysis for Solar Energy Facility using Standard Broiler House Roof)

  • 김진현;정성진;김태욱;최준학;하유신
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.57-65
    • /
    • 2014
  • In order to reduce greenhouse gas emissions in recent agricultural energy and increase the energy self-sufficiency rate of each farmer, it is extremely important to expand the supply of solar energy using unused space of agricultural facilities, roof. This study surveyed and analyzed the environmental and administrative factors such as problems according to the structure, azimuth and latitude of broiler houses and stability of standard broiler houses required to use broiler house roof based on the poultry houses in Sangju-si. The results can be summarized as follows: 55.6% of the solar energy facilities of according to the classification of arable lands of broiler houses were available, and 31.7% of them were available by classifying according to the azimuth. However, 20.6% of them were available in the survey considering all the arable land and azimuth. In the roof inclination of the broiler houses, from 20 to $25^{\circ}$ was the most common, 30 broiler houses. The broiler houses with the roof inclination more than $20^{\circ}$ accounted for 63% of the total. It was considered that the inclination was generally proper. In the structural safety, only 3 broiler houses that were constructed as a standard broiler house were available. In practice, all but one broiler house was inappropriate to expand the solar energy project using roof. The solar thermal facility weighed $63.6kg/m^2$ in total: the frame and solar thermal collector weighed $27.8kg/m^2$ and $35.8kg/m^2$, respectively. The standard broiler house required to be internally reinforced. This study suggested a plan for internal reinforcement and a feasible plan because there were problems with structural safety when installing solar thermal and photovoltaic systems.

윈치커튼식 계사의 시기 및 작업자 출입에 따른 분진 발생 농도 측정 연구 (Measurement of Dust Concentration in a Naturally Ventilated Broiler House according to Season and Worker's Access)

  • 조예슬;권경석;이인복;하태환;박세준;김락우;여욱현;이상연;이승노
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.35-46
    • /
    • 2015
  • Improvement in domestic poultry production has a positive effect on the export competitiveness of the poultry industry. However, overproduction and enlargement of facilities to assure a supply increase a stocking density which make a poor environment in the broiler house. In particular, an intensive rearing environment is vulnerable to dust control that causes respiratory diseases, such as asthma, bronchitis, etc., to farmers and broilers. However, monitoring data and research for environment control are not adequate, and there are no air quality regulations in broiler houses in Korea. In this study, TSP, PM10, inhalable dust and respirable dust concentration were monitored according to season, age of broiler and broiler's activities. Air quality assessment was also performed in accordance with the threshold limit value by Donham et al. (2000). The TSP concentrations were 77.5 %, 219.7 % higher and PM10 concentrations were 121.2 %, 303.8 % higher when change of season and winter respectively than summer. There were significantly different concentrations according to season and age of broiler. Inhalable and respirable dust concentration were also clearly different according to the season and age of broiler. A high dust concentration was observed, specifically exceeding the threshold limit by 119 % in the winter. In the case of the broiler's motion was activity according to worker's access into the broiler house, concentration level was 769.6 % higher than broiler's motion was stable and exceeded the threshold limit. These results suggest that the worker should put on protective equipment to protect there's respiratory health in the broiler house.

강제 환기식 육계사 다중 입기 슬롯에서의 입기류 도달거리 분석 (Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House)

  • 권경석;하태환;이인복;홍세운;서일환
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.55-65
    • /
    • 2012
  • In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption, occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포 (Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea)

  • 김기연
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.

강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석 (Investigation and Analysis of Particulate-matters and Ammonia Concentrations in Mechanically Ventilated Broiler House According to Seasonal Change, Measurement Locations and Age of Broilers)

  • 장동화;권경석;김종복;김중곤;양가영;최성민;장유나
    • 한국농공학회논문집
    • /
    • 제63권1호
    • /
    • pp.75-87
    • /
    • 2021
  • Air quality related to particulate matters and ammonia is being come to the fore as the national concern in Korea. CAPSS (Clean Air Policy Support System) provides emission coefficients of these kinds of particulate and gaseous matters in the fields of livestock; however reliability issues are consistently mentioned. Evaluation of emission rates of PM2.5 and NH3 of the country is very important, but only few studies are available as the background related to observation of the concentration of the particulate matter and ammonia, especially within livestock house in Korea. In this paper, long-term measurement of PM10, PM2.5, and ammonia within the mechanically ventilated broiler house were carried out to introduce backgrounds of generation and emission of the particulate matters and ammonia. Measurement results were analyzed according to seasonal changes, age of broilers(weeks) and measurement locations. Concentration of inhalable and respirable dust were also evaluated in terms of occupational respiratory health according to increase in broiler's activity. From the results of this study, identification of the generation mechanisms of the particulate and gaseous matters, and evaluation of the emission rate of these in the broiler house will be carried out.

강제 환기식 육계사 내부 열환경 균일성 평가 (Internal Thermal Environment Uniformity Analysis of Mechanically Ventilated Broiler House)

  • 김다인;이인복;이상연;박세준;김준규;조정화;정효혁;강솔뫼;정득영
    • 한국농공학회논문집
    • /
    • 제64권6호
    • /
    • pp.65-75
    • /
    • 2022
  • Livestock industry in Korea has been growing rapidly and has reached 23 trillion Korean won in 2021. This study focuses on broiler, which is one of the largest sectors in livestock industry. As the effects of climate change get more serious, primary industry such as livestock industry is fragile to climate change since it directly interacts with nature. Therefore, maintaining suitable rearing environment is important. One of the most frequently used ventilation type for controlling the rearing environment of broiler house, tunnel ventilation, causes frequent air velocity fluctuation which makes maintaining the rearing environment important. By measuring the air temperature, relative humidity and air velocity in various points inside the broiler house, the internal thermal environment uniformity was analyzed according to length, width and zone. The experimental house was found to have dead zone with high air temperature, relative humidity and low air velocity near the end of the inlet and at the end of the broiler house. By using heat stress index to analyze quantitatively, zone with highest heat stress index was found to increase by 7.55% compared to the lowest zone. As a result, to maintain uniform rearing environment inside the broiler house, different factors must be measured and analyzed and used to operate the environmental control facilities.

실험 무창육계사의 환경효율 분석 (Environmental Efficiency Analysis of an Enclosed Experimental Broiler House)

  • 황보종;송준익;조성백;정광화;이병석;남병섭;정찬성;정일병
    • Journal of Animal Science and Technology
    • /
    • 제44권4호
    • /
    • pp.475-482
    • /
    • 2002
  • 본 연구는 무창계사에 대한 효율 비교분석 연구가 전무한 실정으로 무창계사의 환경효율을 검증하고자 하였다. 본 실험은 축산기술연구소 신축 실험계사에서 2002년 5월 9일에서 5월 30일 사이에 실시하였으며 실험결과는 다음과 같다. 1. 무창계사는 외부의 기온은 9.6${\sim}$21.2$^{\circ}C$로 편차는 약 11.6$^{\circ}C$를 나타내었는데 비하여 단열이 우수한 무창계사에서는 병아리 사육적온기인 32${\sim}$33$^{\circ}C$ 범위를 유지하여 약간의 보조열원으로 낮과 밤의 편차는 2$^{\circ}C$ 이상 나타나지 않아 온도효율이 높았다. 2. 공기풍속에 있어서는 무창계사는 상부 0.57 m/sec, 하부 0.04 m/sec로 각각 나타나, 계사내 적정 풍속유지를 위한 덕트입기구의 천공으로 인하여 계사내 전체공간에서 공기의 유속흐름 분포가 고르게 나타났다. 이상의 실험결과를 종합해 볼 때 조사대상이 된 무창계사의 온도 및 습도 환경이 우수하게 나타났으며, 특히 공기속도는 계사 공간 내에서 아주 고른 분포를 가져와 측벽 덕트 입기사설과 측벽 배기기스템이 우수하였다.